Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
St Andrews Manor-LR011025
Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: The Holmes Builders, Inc. DATE: 25 October 2001 PROJECT: St. Andrews Manor-Storm Drainage, Sanitary JOB NO.: 01.1076 Sewer & Water Improvements, 748 DeForest, Coppelll, TX MATERIAL DESCRIPTION: 1) On-Site Fill - Reddish Brown Clayey Sand 2) Borrow Fill - Reddish Brown Clayey Sand 3) On-Site Fill - Dark Grey Sandy Clay ASTM D 698 STANDARD PROCTOR: 1) 111.0 pcf @ 13.0% Moisture 2) 108.0 pcf @ 13.5% Moisture 3) 94.0 pcf @ 19.5% Moisture MOISTURE DRY PERCENT REQUIRED LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION % PCF % % Drive Area 1 ) approx. 100' N of DeForest Rd. 1 Exist. Sub. 11.0 114.7 103.3 95 + 2) approx. 400' N of DeForest Rd. 1 Exist. Sub. 11.8 113.9 102.6 3) approx. 650' N of DeForest Rd. 2 1 15.2 112.4 104.1 4) approx. 600' N of DeForest Rd. 2 2 13.6 110.6 102.4 5) approx. 100' S of N turnaround 3 Exist. Sub. 22.9 98.0 104.3 6) approx. 400' S of N turnaround 3 Exist. Sub. 22.4 97.8 104.0 TECHNICIAN: CDJ DISTRIBUTION: (1) The Holmes Builders, Inc. (1) City of Coppell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148