DR9401-SP 950621 TEXAS INDUSTRIES, INC. 1341 W. MOCKINGBIRDLANE · DALLAS, TEXAS 75247-6913 · (214)647-6700 June 2], ]995 Humphrey & Morton Construction Fort Worth, Tx 76]24 Attention Ronnie Wasson RE: Shadow Ridge Devonshire ~8272 Gentlemen: The attached concrete mix design utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate is proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix design, when ordered by specified design identity, will meet or exceed the indicated design strength at a designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI 318 Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94-86a Section 14.4 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a bas~s for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. Customer Service Coordinator MIX # 8272 5.00SK ADMIX/AEA 1"CS 3000 PSI @ 28 Days AS REQUIRED Maximum Coarse Aggregate Size: ASTM C 33 1" #4 Crushed Stone Maximum Water/Cement Ratio: 6.40 gal/sk .567 lb/lb Minimum Cement Content per Cubic Yard: 5.00 sacks Maximum Placement Slump: 5.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER 1 CUBIC YARD AT S.S.D. 470 lbs. or 5.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1"- #4 Crushed Stone 1352 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Aif Content: 3% - 6% Placement Slump: 4.0 + or - 1 inches PUMPING RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Slumps and test cylinders should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. We are enclosing all available back up data for the above referenced mix design. If the strength information is not available or is not sufficient, conformation cylinders may have to be made by your testing laboratory. TEXAS I~US?RIES, INC. CONCRETE DESIGN EVALUATION Date: 06/21/95 ** Statistics Compiled From Independent Laboratory Test Specimens ** Page: 1 Mix No. F,8272 Strength 3000 psi @ 28 Days 28 Day Test Data Test Plant Temperature Placement Percent ....... 28 Day ....... Cum #oving No. Date No. Arab Con Slump of Air PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 1 03/30/95 40 N/A N/A 5.0 N/A 4760 4770 4765 4765 4765 10 2 03/30/95 40 57 62 5.0 3.6 5040 5000 5020 4893 4893 40 3 03/31/95 40 50 65 5.0 4.4 5010 5060 5035 4940 4940 50 4 03/31/95 40 55 65 5.0 4.6 4640 4150 4395 4804 4817 490 5 04/03/95 46 N/A 68 5.0 5.0 4300 4290 4295 4702 4575 10 6 04/03/95 46 N/A 68 5.5 5.2 4200 4280 4240 4625 4310 80 7 04/06/95 31 64 69 5.5 4.4 4190 4280 4235 4569 4257 90 8 04/07/95 40 72 73 5.5 N/A 4410 4240 4325 4539 4267 170 9 04/08/95 31 86 85 5.0 4.0 4200 4140 4170 4498 4243 60 10 04/08/95 31 78 78 6.0 4.5 4100 4110 4105 4459 4200 10 11 04/08/95 31 86 84 4.5 4.0 4460 4560 4510 4463 4262 100 12 04/08/95 31 81 83 5.5 4.5 4290 4410 4350 4454 4322 120 13 04/10/95 43 58 67 5.5 N/A 4200 4000 4100 4427 4320 200 14 04/11/95 40 60 64 6.0 N/A 3940 4170 4055 4400 4168 230 15 04/12/95 46 N/A 65 4.5 4.1 3430 3570 3500 4340 3885 140 16 04/13/95 31 80 82 4.7 4.7 4010 4140 4075 4323 3877 130 17 04/13/95 31 70 75 5.5 4.6 4130 4030 4080 4309 3885 100 18 04/13/95 31 61 71 5.2 5.0 4150 4010 4080 4296 4078 140 19 04/13/95 40 72 77 5.2 N/A 4500 4450 4475 4306 4212 50 20 04/14/95 40 85 78 5.7 N/A 3920 3920 3920 4287 4158 21 04/17/95 18 78 75 3.5 N/A 4250 3940 4095 4277 4163 310 22 04/17/95 40 77 78 5.0 4.7 4700 4660 4680 4296 4232 40 23 04/19/95 31 69 79 5.7 4.6 4230 4190 4210 4292 4328 40 24 04/19/95 31 69 68 5.7 4.9 4000 3920 3960 4278 4283 80 25 04/19/95 31 69 80 5.0 6.5 4110 4080 4095 4271 4088 30 26 04/24/95 46 N/A 74 4.5 N/A 4010 3990 4000 4260 4018 20 27 11/16/95 31 N/A 63 5.7 6.2 5090 4920 5005 4288 4367 170 28 11/18/95 18 70 74 4.0 N/A 4570 4640 4605 4299 4537 70 29 12/16/95 12 56 68 5.5 N/A 4620 4530 4575 4309 4728 90 30 12/16/95 12 55 68 6.0 N/A 5370 5430 5400 4345 4860 60 *** Averages *** 69 73 5.2 4.7 COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix No. E8272 Strength 3000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of {f'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a 'standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f! ~.~ cr f c + 1.34(SD) : 3000 + 1.34(00403) = 3540 f' : f' + 2.33(SD) 500 cr c : 3000 + 2.33(00403) 500 = 3439 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 5400 psi Minimum Value ............................ 3500 psi Range .................................... 1900 psi Average Strength ......................... 4345 psi Standard Deviation ....................... 403 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 3540 psi Design excess beyond code requirements.. 805 psi TEXAS INDUSTRIES, INC. CEMENT DIVISION, 245 Ward Road Midlothlan, Texas 76065 SPECIFICATIONS Portland Cement Type 1/11 (Low Alkali) A.S.T.M. C150-94 A.A.S.H.T.O. M 85-911 Bin Number Car Number Tons Date of Sampling February 1995 Monthly Average I SPECIFICATIONS I TEST ASTM ,AASHTO RESULTS Silica Oxide, Minim.:m Percent 20.0 20.0 20.3 Alumina Oxide, Ma~ ,mum Percent 6.0 6.0 5 Iron Oxide, Maximum Percent 6.0 6.0 4 Magnesia Oxide, Maximum Percent 6.0 6.0 0.9 SO3 (C3A less than 8%), Maximum Percent * * 3.6 Loss on Ignition, Maximum Percent 3.0 3.0 0.9 Insoluble residue, Maximum Percent 0.75 0.75 C.22 Tricalcium Aluminate, Maximum Percent 8 8 7 Tricalcium Silicate, Maximum Percent ;: .:.: :. 55 59 Total Alkalies, Max. % (Na20 equiv.) I 0.60 I 0.60 I 0.48 :Specific surface, Minimum (M*2/Kg) I 160 160 Wagner Maximum (M~2/Kg) I : 28;0 ' 220 t 90 Specific '"~""'¢- su ........ , Minimum (M^2/Kg) 280 B~aine Maximum (M"2IKg) :: 400 323 Gillmore, Initial Set, Minimum (Minutes) 60 60 172 Giilmore, Final Set, Maximum (Minutes) 600 600 296 Vicat, ~ (Minutes) 45 45 Initial Set IMaximum ~) 375 375 1 07 Air Content, Volume Maximum Percent 12 12 6 Autoclave Expansion, Maximum Percent 0.80 0.80 0.01 3 Day Minimum Compressive Strength, PSI 1800 1800 3984 7 Day Minimum Compressive Strength, PSI 2800 2800 4918 STATE OF TEXAS ELLIS COUNTY J.R. Owens , being duly sworn deposes and says; that he is Chief r~ K C COKER Tex--a"~n~-~s, Inc., Cement Division, who prepared the above report of · Notary Public that the same Is true and correct. Subscribe~/~,,d sworn to before me this 13tn day of March, 1995. ~ot/ary Public Ch~ Chemist · See ASTM C150 Table 1, Footnote B. Construction Products Division C~AC~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that DARATARD-17, a water-reducing set- retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentratiOn, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. ely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements recommendations or suggestions herein in conjunction wilh our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend lhe.n as a recommendation for any use which would infringe any patent or copyright. Construction Products Division ~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied bythe Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be Irue and accurate. Please read oll statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to oll goods supplled by us. We assume no responsibility for the use of these statements, recommendations, Or suggestions, nor do we intend thegn as a recommendation for any use which would infringe any patent or copyright. Construction Products Division ~ W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that Daravair 1000, an air-entraining admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C260 (AASHTO M154). Daravair 1000 does not contain calcium chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The foregoing is in addition to and not in substitution for our standard Conditions of Sales printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 06/06/95 #ALL Tests Production Facility: BRIDGEPORT Size #: 57 Grading Designation: ASTM C-33 ~" - #4 Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % Passinq % Retained % Passing 1.0" 1.63 98.37 0 - 5 95 - 100 3/4" 17.29 82.71 1/2" 55.46 44.54 40 - 75 25 - 60 3/8" 79.40 20.60 #4 97.27 2.73 90 - 100 0 10 #8 98.80 1.20 95 - 100 0 5 #10 #16 #30 #40 #50 #100 #200 99.13 0.87 Pan Wt. ~ecant .89% Tested By: , ~7~~ ~Y '6/~ 100% of 147 tests: Size 57 Plant: BRIDGEPORT Job: ***** ALL JOBS ***** TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 04/13/95 #ALL Tests Production Facility: PAI~ADISE Size #: 33 Grading Designation: ASTM C-33 FINE AGG. Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % Passinq % Retained % Pa$~in~ 1.5" 3/4,~ 3/8" #4. 1.79 98.21 0 - 5 95 - #8 )8,gg 81.01 0 - 20 80 - 10C #1o #16 34.98 65.02 15 - 50 .50 - #30 50.13 49,87 40 - 75 25 - 6C #4O #50 72.26 27.74 70 - go 10 - 3( #100 95.16 4.84 90 - 98 2 - #200 98.86 1.14 P~n Wt. 2.73 Fineness Modulus Tested By: _ 100% of 163 tests: Size 33 Plant: PARADISE Job: ***** ALL JOBS *****