ST9302-LR011105 ALPHA TESTING, INC.
Concrete
Test
2209 Wisconsin St., Suite 100 , omt, ress,on
Dallas, Texas 75229 -bo"or*
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-224
ATTN: KEN GRIFFIN Issue Date: 11/0512001
255 PARKWAY BLVD.
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
FIELD DA TA
Placement Location: PAVING, MEDIAN CURB ON MACARTHUR RD. @ STATION 4+25
Date Placed: 10/3/01 Plant Number: 42-6.0 SK
Time Placed: 12:15 PM Delivery Tlcket No.: 2993115
Slump (ASTM C-143): 2.75 Made By:. ALPHA
Air Content: 5.0 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 92
Specimen Temperature: 84
Date Received: 10/4/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: MCMILLAN, JOHN
Mix Data Submitted By:. TXI
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: 1'~38: Spec: Tested: (Da~sl: Len~h Width Diameter Sq. In. Load: PSI:
322 LAB C-1231 10/10/01 7 12 N/A 6 28.27 120420 4250
323 LAB C-1231 10/31/01 28 12 N/A 6 28.27 143070 5060
324 LAB C-1231 10/31/01 28 12 N/A 6 28.27 142450 5030
325 LAB HOLD HOLD 12 N/A 6 28.27 0
' Specifications: 28 3500
Results to Date: PASS
Notes:
CC: CITY OF COPPELL, ED BELL CONSTRUCTION
Respectfully Submitted By: ~'f~ ~/'~v~ of Alpha Testing, Inc.
Our test results and relx~ls are for the exclusive use of the Client their ded~nated receplents ou file In our office) and shall not be reproduced and/or distributed except
with exlxess approval of ALPHA. The ~se of oar name and test results must receive our written apl)roval. Test resulls and reports apply only to the samples tested and/or
observed, and are not IndlcaOve of the qualities of apparenOy identical or similar specimens.