Town Center L4B1-LR011113 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 l enort
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP Our Report No.: 01612-36
ATTN: MR. JEFF MILLER Issue Date: 11/13/2001
Fax Number: (214) 521-1279
Project D~c.' COPPELL TOWN CENTER '7~)0.)~ C~[7~. ~ Z~l b ~L ~i~K 120/TON TAPP- COPPELL, TX
FIELD DA TA
Placement Location: GRADE BEAM, 30'S & 4'E FROM THE NW CORNER OF THE BUILDING
Date Placed: 10/25/01 Plant Number: 89-3000
Time Placed: 12:30 PM Delivery Ticket No.: 89003910
Slump (ASTM C-143): 5 Made By: ALPHA
Air Content: N/A Cured Specification: ASTM C-31
Air Temperature: 85
Specimen Temperature: 88
Date Received: 10/26/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: YEOMAN, RONALD
Mix Data Submitted By: BEALL
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
57 LAB C-1231 11/1/01 7 12 N/A 6 28.27 96990 3430
58 LAB 11/22/01 28 12 N/A 6 28.27 0
59 LAB 11/22/01 28 12 N/A 6 28.27 0
60 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Date: N/A
Notes:
CC: HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ,.. of AJpha Testing, Inc.
Our test results and repons are for the exclnslve use of the Client (and their designated receplents on file in our office) and shall not be reproduced and/or dbtrlbuted except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indkative of the qualities of apparenlty Identical or similar specimens.