Vistas of C SL-CS 960805 Notice of Proposed Installation
Utility Line on Controlled Access Highway
Form 1082 (Rev. 9-93)
(Previous version(s) are obsole'(e.)
To the Texas Transportation Commission Date August 5, 1996
c/o District Engineer
Texas Department of Transportation
Dallas , Texas
Formal notice is hereby given that City of Coppell (By Contractor)
Company proposes to place a 10" S~nt tar¥ ~ewer Line "E"
line within the right-of-way of proposed 121 Bypass in Dallas]Denton County,
Texas as follows: (give location, length, general design, etc.)
LOCATION: Proposed Rwy 121 Bypass at Ridgemont Drive
LENGTH: 400 LF.
DESIGN: 55 LF. Dry Bore with casing pipe in each crossing (Eastbound & Westbound)
400 LF. SDR 35 PVC Sewer pipe 10" diameter.
1 EA. 4.0t diameter. Standard ~anhole over existing 12" S~nttary Sewer Line
The line will be constructed and maintained on the highway right-of-way as shown on the attached drawing and in
accordance with the rules, regulations and policies of the Texas Department of Transportation (TxDOT), and all
governing laws, including but not limited to the "Federal Clean Water Act," the "Federal Endangered Species Act," and
the "Federal Historic Preservation Act." Upon request by TxDOT, proof of compliance with all governing laws, rules, and
regulations will be submitted to TxDOT before commencement of construction.
Our firm will use Best Management Practices to minimize erosion and sedimentation resulting from the proposed
installation, and we will revegetate the project area as indicated under "Revegetation Special Provisions."
Our firm will insure that traffic control measures complying with applicable portions of the Texas Manual of Uniform
Traffic Control Devices will be installed and maintained for the duration of this installation.
The location and description of the proposed line and appurtenances is more fully shown by 3 complete
sets of drawings attached to this notice.
Construction of this line will begin on or after the receipt day of permit ,19 96
By signing below, I certify that I am authorized to represent the Firm listed below, and that the Firm agrees to the
conditions/provisions included in this permit.
Firm City of Coppell
By (Print) Kenneth lq. ~[~Atffin
Title Assistant City lqanager/City Engineer
Address 255 Parkway Blvd.
Coppell, ~X 75019
Phone No. (214) 304-3679
Form 1082 (Rev. 09-93)
(Previous Versio~ Obsolete)
APPROVAL
To: Hwy. No.
Beg. RM__ Ofiset End RM__Offset
Maintenance Section No.
County
Date
The Texas Department of Transportation (TxDOT) offers no objection to the location on the right-of-way of your proposed
line as shown by accompanying drawings and notice dated except
as noted below.
Your attention is directed to governing laws, especially to Article 6674w-1, Vernon's Annotated Civil Statutes of Texas, pertaining
to Control of Access. Access for serving this installation shall be limited to access via (a) frontage roads where provided, (b)
nearby or adjacent public roads or streets, (c) trails along or near the highway right-of-way lines, connecting only to an intersecting
road; from any one or all of which entry may be made to the outer portion of the highway right-of-way for normal service and
maintenance operations. The Owner's rights of access to the through-traffic roadways and ramps shall be subject to the same rules
and regulations as apply to the general public except, however, if an emergency situation occurs and usual means of access for
normal service operations will not permit the immediate action required by the Utility Owner in making emergency repairs as
required for the safety and welfare of the public, the Utility Owners shall have a temporary right of access to and from the through-
traffic roadways and ramps as necessary to accomplish the required emergency repairs, provided TxDOT is immediately notified
by the Utility Owner when such repairs are initiated and adequate provision is made by the Utility owner for convenience and
safety of highway traffic.
It is expressly understood that the TxDOT does not purport, hereby, to grant any right, claim, title, or easement in or upon this
highway: and it is further understood that the TxDOT may require the owner to relocate this line, subject to provisions of
governing laws, by giving thirty (30) days written notice.
You are requested to notify this office prior to commencement of any routine of periodic maintenance which requires pruning
of trees within the highway right-of-way, so that we may provide specifications for the extent and methods to govern in trimming,
topping, tree balance, type of cuts, painting cuts and clean up. These specifications are intended to preserve our considerable
investment in highway planting and beautification, by reducing damage due to trimming.
The installation shall not damage any part of the highwa,, a,,,~ adequate provisions must be made to cause minimum inconveniences
to traffic and adjacent property owners. In the event me Owner fails to comply with any or all of the requirements as set forth
herein, the State may take such action as it deems appropriate to compel compliance.
· General Special Provisions:
· Revegetation Special Provisions: In order to minimize erosion and sedimentation resulting from the proposed installation, the
project area will be revegetated
[] in accordance with TxDOT's Standard Specification Item 164 which specifies the appropriate grass seed mix to be used, or
[] as indicated on the attachment.
Please notify, forty-eight (48) hours prior to
starting construction of the line in order that we may have a representative present.
Texas Department of Transportation
By:
District Engineer--District No.