Welcome Home-CS 980716 CITY OF COPPELL
PLANNING DEPARTMENT
STAFF REPORT
CASE NO.: S-1146, BLUE WILLOW MARKET DESIGN
P & Z HEARING DATE: July 16, 1998
C.C. HEARING DATE: August 11, 1998
LOCATION: 416 W. Bethel Road.
SIZE OF AREA: 0.62 acres, 1567 s.f. building
CURRENT ZONING: HO-R (Historic Overlay, Retail)
REQUEST: HO-R-S.U.P. (Historic Overlay, Retail-Special Use Permit) for
business use of a residential structure and for use of asphalt
pavement.
APPLICANT: Joy E. Onstott
14410 Southern Pines Court
Dallas TX 75234
972-247-2750
HISTORY: The property is considered "business property with residential
structure". Therefore, a special use permit is required prior to
using the structure for business purposes. In August of 1993,
Phillip Jewitt obtained a special use permit to operate a girl shop.
The type of goods to be sold were for outdoor use such as
fountains, monuments and water gardens. The current applicant
later acquired the property and moved her flower shop from 420
West Bethel Road next door to this property. The use was
considered similar enough in nature that the City did not require a
new special use permit. However, the parking spaces shown on
the site plan approved in 1993 were never paved nor designated on
the site. Now that the property has been voluntarily vacated by the
flower shop, a new special use permit is required.
TRANSPORTATION: Bethel Road is a two-lane asphalt roadway shown on the
thoroughfare plan as a C2U two-lane undivided collector. The
property also has access to Mitchell Road through a 30'-wide
access easement.
Item # 4
SURROUNDING LAND USE & ZONING:
North- Single-family residential; HO-R and HO-PD-SF7
South - Scattered single-family structures; HO-R and HO-PD-LI
East - Single-family structure; HO-R
West- Business property with residential structure and single-family
residential; HO-R and HO-R-SUP
COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for
historic district uses.
DISCUSSION: The property is 90 feet wide and approximately 300 feet deep. The structure
is nearly 30 feet wide, with 38 feet between it and the west property line and
22 feet between it and the east property line. Parking in the rear would not
be visible nor particularly useful, except for employees. The only practical
location for customer parking, therefore, is directly in front.
It is possible to pave an area in front of the building sufficient for 6 cars to
park, turn around, and exit without backing into Bethel Road. The paved
area can observe the required 10'-wide landscape buffers on each side, and
will infringe only partially into the 15'-wide landscape buffer required on the
front. Given the site constraints, this is the least intrusive configuration staff
has found for providing adequate parking. The applicant is requesting
permission to use asphalt paving.
The proposed use of the property is for an interior design office with a
limited amount of retail showroom. Six parking places is sufficient for a
maximum of 400 square feet of retail. The remainder of the 1567-square-
foot building will have to used as office space. (400 square feet at 1 parking
place per 200 square feet of retail = 2 parking places; 967 square feet at 1
parking place per 300 square feet of office = 4 parking places; for a total of
6.) Therefore, any approval recommendation needs to contain a condition
limiting the amount of retail space to an area no greater than 400 square feet.
The 90' width of the property precludes the use of a free-standing sign.
(Over 150' of width is required for a monument sign.) Consequently all
signage must be attached to the building. The applicant's prospective tenant
has provided no drawings to show the nature of any proposed attached sign.
If there is to be a sign on the building, the Commission needs to review the
design to make sure that it is compatible with the historic character of the
Finally, the plan submitted does not specify landscape materials. A low
landscape screen along the front and each side of the parking area is
required. Without a landscape plan submitted for approval, the Commission
will need to specify the number, size, spacing and species of plant materials
required to accomplish the required vehicular screening.
Item # 4
RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION:
The planning staff recommends approval of a Special Use Permit for use of
asphalt pavement and for use of a residential structure for office and retail
purposes subject to Engineering Comments and the following conditions:
1. Retail use shall be limited to no more than 400 square feet, unless
additional paved employee parking is provided at the rear of the
property.
2. No signs shall be installed without approval of the design by the
Planning and Zoning Commission and City Council.
3. All vehicular pavement shall be screened from front and side property
lines with a hedge at least 30 inches in height at the time of planting
and consisting of a minimum of 30 plants. All plants shall be of the
same variety, the plant variety to be one of the following: abelia,
eleagnus, holly or nandina. Fifteen plants shall be placed east of the
driveway entrance spaced at 3' on center. The other 15 plants shall
be placed west of the driveway entrance spaced at 3' on center. Plant
materials which die shall be replaced with plant material of the same
variety and size.
ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request
3) Recommend modification of the request
4) Take under advisement for reconsideration at a later date.
ATTACHMENTS: 1) Departmental Comments
2) Site plan
Item # 4
DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM: S-1146. Welcome Home Interior Design, a zoning change request from "HO-
R" (I-Iistoric Overlay, Retail) to "HO-R-S.U.P (tlistoric Overlay, Retail,
Special Use Permit) to allow a business within a residential structure in a
commercial district and on-site a~phalt paving in the Historic Overlay District
located at 416 W. Bethel Road, at the request
DRC DATE: June 25, 1998and July 2, 1998
CONTACT: Mike Martin, P.E.,/lssistant City Engineer (304-3679)
COMMENT STATUS:
1. What happens to drainage ditch across the front of the property? Need to specify 18" RCP.
2. Show location of adjacent driveways.
3. Need to provide a vicinity map.