Loading...
Waterside P3-LR 950524 (2) TEXAS INDUSTRIES, INC. 1341 W. MOCKINGBIRDLANE · DALLAS, TEXAS 75247-6913 · (214) 647-6700 May 24, 1995 Austin Bridge & Road 11143 Goodnight Lane Dallas, Tx 75229 Attention Mr. Gary Atwood RE: Waterside Estates #3 - Coppell 8272 8274 Gentlemen: The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix designs, when ordered by specified design identity, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C g4, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94-86a Section 14.4 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix designs prior to their use. To ensure that the proper mix designs are ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. Bruce Bach Customer Service Representative MIX # 8272 5.00SK ADMIX/AEA 1"CS 3000 PSI @ 28 Days AS REQUIRED Maximum Coarse Aggregate Size: ASTM C 33 1"- #4 Crushed Stone Maximum Water/Cement Ratio: 6.40 gal/sk .567 lb/lb Minimum Cement Content per Cubic Yard: 5.00 sacks Maximum Placement Slump: 5.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER 1 CUBIC YARD AT S.S.D. 470 lbs. or 5.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1"- #4 Crushed Stone 1352 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3% - 6% Placement Slump: 4.0 + or - 1 inches MIX # 8274 6.00SK ADMIX/AEA 1"CS 3600 PSI @ 28 Days SLIP FORM PAVING Maximum Coarse Aggregate Size: ASTM C 33 1"- #4 Crushed Stone Maximum Water/Cement Ratio: 5.33 gal/sk .472 lb/lb Minimum Cement Content per Cubic Yard: 6.00 sacks Maximum Placement Slump: 4.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER 1 CUBIC YARD AT S.S.D. 564 lbs. or 6.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1'~- #4 Crushed Stone 1273 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type D Specified Air Content: 3% - 6% Placement Slump: 3.0 + or I inches PUMPING RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Slumps and test cylinders should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. We are enclosing all available back up data for the above referenced mix design. If the strength information is not available or is not sufficient, conformation cylinders may have to be made by your testing laboratory. TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION Date: 05/24/95 ** Statistics Compiled From Independent Laboratory Test Specimens ** Page: 1 Mix No. E8272 Strength 3000 psi @ 28 Days 28 Day Test Data Test Plant Temperature Placement Percent ....... 28 Day ....... Cum Moving No. Date No. Amb Con Slump of Air PSI 1 PSI 2 PSI avg Avg Avg of 3 Range 1 02/20/95 40 69 64 5.0 N/A 4800 4510 4655 4655 4655 290 2 02/20/95 47 N/A 73 5.0 3.5 4370 4360 4365 4510 4510 10 3 02/21/95 40 55 58 5.0 4.0 3190 3410 3300 4107 4107 220 4 02/21/95 40 66 62 5.0 4.2 3980 4090 4035 4089 3900 110 5 02/22/95 40 54 61 4.5 4.9 4810 4800 4805 4232 4047 10 6 02/22/95 50 65 60 3.7 N/A 4700 3930 4315 4246 4385 770 7 02/23/95 46 60 64 3.5 5.5 4020 4300 4160 4234 4427 280 8 02/23/95 40 66 70 5.0 5.0 4080 4140 4110 4218 4195 60 9 02/24/95 40 58 64 4.5 5.2 4620 4870 4745 4277 4338 250 10 02/24/95 12 70 N/A 4.0 N/A 4210 4230 4220 4271 4358 20 11 02/24/95 12 70 N/A 3.5 ~/A 4050 4120 4085 4254 4350 70 12 02/27/95 35 75 N/A 3.7 N/A 4580 3610 4095 4241 4133 970 13 03/01/95 50 36 55 4.0 5.0 4690 4550 4620 4270 4267 140 14 03/07/95 47 67 70 4.0 4.0 4580 4540 4560 4291 4425 40 15 03/09/95 38 59 68 4.0 6.1 3720 3540 3630 4247 4270 180 16 03/09/95 40 46 52 5.0 5.0 4170 4030 4100 4238 4097 140 17 03/09/95 40 52 52 5.0 N/A 3310 3630 3470 4192 3733 320 18 03/10/95 40 43 53 5.0 5.2 3630 3610 3620 4161 3730 20 19 03/10/95 40 50 53 5.0 5.5 3780 3870 3825 4143 3638 90 20 03/11/95 40 N/A 63 5.5 4.3 4340 4290 4315 4152 3920 50 21 03/11/95 40 N/A 63 5.5 4.4 4110 4070 4090 4149 4077 40 22 03/11/95 40 ~/A 63 5.5 4.3 4450 4280 4365 4158 4257 170 23 03/11/95 40 N/A 64 5.7 4.0 4300 4280 4290 4164 4248 20 24 03/11/95 40 N/A 64 5.5 4.0 4380 4420 4400 4174 4352 40 25 03/11/95 40 M/A 64 5.7 4.2 4030 4010 4020 4168 4237 20 26 03/11/95 40 N/A 59 4.5 4.0 5370 5240 5305 4212 4575 130 27 11/16/95 31 N/A 63 5.7 6.2 5090 4920 5005 4241 4777 170 28 11/18/95 18 70 74 4.0 ~/A 4570 4640 4605 4254 4972 70 29 12/16/95 12 55 68 6.0 N/A 5370 5430 5400 4293 5003 60 30 12/16/95 12 56 68 5.5 N/A 4620 4530 4575 4303 4860 90 *** Averages *** 59 63 4.8 4.7 COMMENTARy OF STATISTICAL EVALUATION OF CONCRETE. DESIGN RESULTS Mix No. E8272 Strength 3000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of (f'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f' : f' + 1 34(SD) cr c ' : 3000 + 1.34(00486) : 3651 f' : f' + 2 33(SD) 500 cr c ' = 3000 + 2.33(00486) - 500 3632 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 5400 psi Minimum Value ............................ 3300 psi Range .................................... 2100 psi Average Strength ......................... 4303 psi Standard Deviation ....................... 486 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 3651 psi Design excess beyond code requirements.. 652 psi TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION Date: 05/24/95 ** Statistics Compiled From Independent Laboratory Test Specimens ** Page: 1 Mix No. H8274 Strength 3600 psi @ 28 Days 28 Day Test Data Test Plant Temperature Placement Percent ....... 28 Day ....... Cum Moving No. Date No. Amb Con Slump of Air PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 1 11/04/93 46 75 78 4.5 3.5 5500 5340 5420 5420 5420 160 2 11/05/93 46 58 N/A 4.2 3.9 4860 4950 4905 5163 5163 90 3 11/05/93 46 58 N/A 3.5 4.2 5380 5340 5360 5228 5228 40 4 11/08/93 46 56 N/A 6.0 3.7 5220 5160 5190 5219 5152 60 5 11/08/93 46 N/A N/A 5.0 3.4 4900 4990 4945 5164 5165 90 6 11/09/93 46 58 N/A 4.5 2.9 4850 4900 4875 5116 5003 50 7 11/09/93 46 58 N/A 4.7 3.6 4700 4420 4560 5036 4793 280 8 12/01/93 18 N/A 74 4.7 N/A 4560 4330 4445 4963 4627 230 9 12/16/93 46 N/A 58 4.2 3.6 5910 5640 5775 5053 4927 270 10 12/29/93 12 53 60 4.0 N/A 5220 5160 5190 5067 5137 60 11 04/11/94 41 N/A 73 3.0 4.1 4810 4850 4830 5045 5265 40 12 04/14/94 41 80 70 3.2 3.8 4810 4850 4830 5027 4950 40 13 10/10/94 13 83 76 7.0 N/A 4710 4700 4705 5002 4788 10 14 11/21/94 40 N/A 76 4.5 4.4 6680 6530 6605 5117 5380 150 15 11/29/94 47 63 72 6.0 N/A 6420 6320 6370 5200 5893 100 16 12/05/94 47 57 70 5.0 3.8 5080 5250 5165 5198 6047 170 17 12/21/94 12 42 59 5.5 N/A 4460 4580 4520 5158 5352 120 18 12/21/94 12 56 62 5.5 N/A 4660 4980 4820 5139 4835 320 19 12/21/94 12 61 64 6.0 N/A 4300 4320 4310 5096 4550 20 20 02/02/95 35 46 60 3.5 4.8 5620 5660 5640 5123 4923 40 21 02/02/95 35 47 61 4.5 5.2 4240 4780 4510 5094 4820 540 22 02/02/95 35 49 60 4.0 5.4 5000 4700 4850 5083 5000 300 23 02/02/95 35 51 62 4.5 5.0 4840 4780 4810 5071 4723 60 24 02/03/95 35 49 62 4.5 5.7 4210 4780 4495 5047 4718 570 25 02/03/95 35 51 62 4.5 5.5 4580 4510 4545 5027 4617 70 26 02/03/95 35 53 63 4.5 5.3 4670 4510 4590 5010 4543 160 27 02/03/95 35 60 63 4.0 4.9 5040 4840 4940 5007 4692 200 28 02/07/95 12 50 N/A 4.5 N/A 5580 5660 5620 5029 5050 80 29 02/08/95 40 N/A 63 4.7 4.9 4750 5070 4910 5025 5157 320 30 03/08/95 40 N/A 64 3.5 2.7 6200 6280 6240 5066 5590 80 *** Averages *** 57 66 4.6 4.3 COMMENTARY OF STATISTICAL EVALUATION OF CONCR~T~ DESIGN RESULTS Mix No. H8274 Strength 3600 psi ~ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of (f'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f' : f' + 1.34(SD) cr c : 3600 + 1.34(00588) = 4388 f' = f' + 2.33(SD) - 500 cr c : 3600 + 2.33(00588) 500 : 4470 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 6605 psi Minimum Value ............................ 4310 psi Range .................................... 2295 psi Average Strength ......................... 5066 psi Standard Deviation ....................... 588 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 4470 psi Design excess beyond code requirements.. 596 psi "tx TEXAS INDUSTRIES, INC. ~® CEMENT DIVISION, 245 Ward Road Midlothian, Texas 76065 SPECIFICATIONS Portland Cement Type 1/11 (Low Alkali) A.S.T.M. C150-94 A.A.S.H.T.O. M 85-911 Bin Number Car Number Tons Date of Sampling February 1995 Monthly Average I SPECIFICATIONS I TEST !,AS. O · CHEMICAL REQUIREMENTS Silica Oxide, Minim :m Percent 20.0 20.0 ,_0.,~ Alurniaa Oxide, Ma..mum Percent 6.0 6.0 5 Iron Oxide, Maximurr, Percent 6.0 6.0 4 Magnes a Oxide, Maximum Percent 6.0 6.0 0.9 SO3 (C3A less than 8%), Maximum Percent * t * 3.6 Loss on Ignition, Maximum Percent 30 ! 3.0 0.9 Insoluble residue, Maximum Percent 0.75 0.75 C.22 -;-ricalcium Aluminate, Maximum Percent 8 8 7 Tricalcium Si!icate, Maximum Percent 55 59 OPTIONAL CHEMICAL REQUIREMENTS .' - Total Alkalies. Max. % (Ne20 equiv.) I 0.60 I 0.60 f 0.48 PHYSICAL REQUIREMENTS · Specific surface. Minimum (M*2/Kg) 160 160 Wagner Maximum fM^2/Kg) 220 ! 90 Specific sur::~.ce, Minimum (M^2/Kg) 280 280 Blaine Maximum (M"2/K9) . 400 323 Gillmore, Initial Set, Minimum Minutes) 60 60 172 Giilmore, Final Set, Maximum (Minutes) 600 600 296 Vicar, Minimum (Minutes) 45 45 Initial Set Max mum M ntJies) 375 375 107 Air Corn. ant, Volume Maximum Percent 12 12 6 IAutoclave ExpAnsion, Maximum Percent 0.80 0.80 0.01  Day Minimum Compressive Strength, PSi 1800 1800 3984 Da.y Minimum Compressive Strc;n~oth, PSI , 2800 2800 , 49t 8 STATE OF TEXAS ELLIS COUNTY J.P. Owens , being duly sworn deposes and says; that I~e is Chief C~'~'~'~'~"~'*~~"~ Te~-a-~n~-(~s, Inc., Cement Division who prepared the above report of ~~~-'~ K.C. COKER ' ~ I~[',~:~,m,y~%~ NoteW Public that the same is true and correct. ~ k:¢¢k~;] STATE OF TEXAS  Comm. Exp. 10/22/98 Subscribed/nd sworn to before me this 13tn day of March, 1995. ~o~ry Public C~ Chemist *See ASTM C150 Table 1, Footnote B. Construction Products Division ~C/E W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that DARATARD-17, a water-reducing set- retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or ~uggestions herein in conjunction with our conditions of sale which apply to oll goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. Construction Products Division GRACE W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. Construction Products Division ~C/E W.R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that DAREX II AEA, an air-entraining admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C-260 (AASHTO M 154). DAREX II AEA does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our condilions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend the,n as a rec0mmendolion for any use which would infringe any patent or copyright. TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 04/07/95 #ALL Tests Production Facility: BRIDGEPORT Size #: 57 Grading Designation: ASTM C-33 1~ - #4 Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % .Passinq % Retained % Passing 2.0~ 1.0'~ .. 1.63 98.37 0 - 5 95 - 100 3/4~ 17.29 82.71 1/2~ 55.46 44.54 40 - 75 25 - 60 3/8~ 79.40 201,60 #4 97.27 2.73 90 - 100 0 - #8 98.80 1.20 95 - 100 0 - 5 #10 #16 #3O #4O #5O #10o #200 Pan Wt. 100% of 147 tests: Size 57 Plant: BRIDGEPORI Job: ~ AL[ dOBS TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 04/13/95 #ALL Tests Production Facility: PARADISE Size #: 33 Grading Designation: ASTM C-33 FINE AGG. Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specification Size Wt. Retained % Retained % Passing % Retained % Passing 3/4" ]/2" 3/8" #4 1.79 98.21 0 5 95 100 #8 18.99 81.01 0 20 80 - 100 #10 #16 34.98 65.02 15 - 50 .50 - 85 #30 50.13 49.87 40 - 75 25 - 60 #40 #50 72.26 27.74 70 - 90 10 - 3C #100 95.16 4.84 90 - 98 2 - lC #200 98.86 1.14 Pan Wt. 2.73 Fineness Modulus M.C. 6.1% Sampled By: F~ S.E. 85.47 Tested By: . _ 100% of 163 tests: Size 33 Plant: PARADISE Job: ***** ALL JOBS *****