Loading...
Waterside P3-LR 950615EWI Ellerbee-Walczak, Inc. CONSTRUCTION MATERIALS TESTING REPORT NO.: AB690den.doc REPORT OF: In Place Density Tests Utilizing Nuclear Gauge FOR: Austin Bridge & Road PROJECT: Waterside Estates/t3 01778 DATE: 6/15/95 NO. PROC % MOIST. % DRY DEN LOCATIONS I I 19.1 96,8 Cove Dr. Sra. 1+00 2 1 20.2 97.6 Sla. 4+00 3 2 24.7 97.1 Sra. 7+00 4 I 20.6 98.0 Center of cul-de-sac 5 2 23.4 98.4 Misty Harbor Ct. 6 1 21.0 97.1 Mariners Ct. Sla. 0+75 7 1 20.2 99.6 Cul-de-sac 8 2 23.7 98.9 Alley H-I Sra. 10+00 9 I 19.6 97.9 Sta. 7+00 10 1 21.2 97.1 S~a. 4+00 11 I 19.1 98.0 Sra. 1+00 12 2 22.2 98.8 Alley H-2 Sra. 4+00 13 I 20.3 97.5 Sra. 1+00 PROCTORS USED: #1 - 105.2 PCF ~ 20.1% #2 - 100.3 PCF ~ 23.6% Ronald A. Ellerbee, C.E.T. cc: Austin Coppell 6900 So. Freeway, Suite A-1 Fort Worth, Texas 76134 Laboratory: (817) 293-0111 (817) 293-0257 Fax: (817) 596-0941