Petterson (Encore)-LR180312 Alpha Testing, Inc. 2209 Wisconsin St In-Place Nuclear Density Dallas, TX 75229 www.alphatesting.com Test Report TBPE Firm No. 813 Client:RECH Coppell, LLCService Date:03/12/2018 4145 Travis Street, Suite 202Report Date:3/12/2018 Dallas, TX 75204Weather:Clear Work Order Number:369287 Project:Petterson Addition - Encore of CoppellProject Number:173166 Tierra Grande Way and Sandy Lake RoadTechnician:Shafi Abubeker 1 Coppell, TexasPage Number:1of Material InformationLaboratory DataProject Specifications OptimumMax Dry Proctor Mat.MoistureCompaction Material Description/ClassificationWeight Moisture Report No. No.Min. (%) Max.Min. (%) Max. (%)(pcf) Brown Silty Clayey Sand with Sandstone Fragments 1211.2116.80495 General Location Area:Utilities: Sanitary Sewer Line A from Station 0+00 to 1+87 and Storm Sewer Line A from Station 4+00 to 6+95 Field Test Data ProbeWetDryPercentPercent TestLift/Mat. Test LocationDepthDensityDensityMoistureCompaction No. DepthNo. (in.)(pcf)(pcf)(%)(%) 61Sanitary Sewer Line A at Station 1+40FG-2.516129.5112.515.196 62Sanitary Sewer Line A at Station 1+41FG-2.016128.5111.914.896 63Sanitary Sewer Line A at Station 1+42FG-1.016130.6113.714.997 64Sanitary Sewer Line A at Station 1+43FG16131.4115.713.699 65Sanitary Sewer Line at Station 6+30FG-1.016132.9116.314.3100 66Sanitary Sewer Line at Station 6+31FG16132.1115.914.099 Non-compliant results are indicated by an asterisk(*) if Gauge Information applicable. Serial No:399Manufacturer:HumboldtModel:5001EZStandard Count:(D):1921.6(M):475.3 Remarks: Respectfully Submitted, Technician:Shafi Abubeker Start Time: Stop Time: Lunch Hrs:Total Hrs:Todd Smith Version 1.9: Date:3/1/18 This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering