Petterson (Encore)-LR180312
Alpha Testing, Inc.
2209 Wisconsin St
In-Place Nuclear Density
Dallas, TX 75229
www.alphatesting.com
Test Report
TBPE Firm No. 813
Client:RECH Coppell, LLCService Date:03/12/2018
4145 Travis Street, Suite 202Report Date:3/12/2018
Dallas, TX 75204Weather:Clear
Work Order Number:369287
Project:Petterson Addition - Encore of CoppellProject Number:173166
Tierra Grande Way and Sandy Lake RoadTechnician:Shafi Abubeker
1
Coppell, TexasPage Number:1of
Material InformationLaboratory DataProject Specifications
OptimumMax Dry
Proctor
Mat.MoistureCompaction
Material Description/ClassificationWeight
Moisture
Report No.
No.Min. (%) Max.Min. (%) Max.
(%)(pcf)
Brown Silty Clayey Sand with Sandstone Fragments
1211.2116.80495
General Location
Area:Utilities: Sanitary Sewer Line A from Station 0+00 to 1+87 and Storm Sewer Line A from Station 4+00 to 6+95
Field Test Data
ProbeWetDryPercentPercent
TestLift/Mat.
Test LocationDepthDensityDensityMoistureCompaction
No.
DepthNo.
(in.)(pcf)(pcf)(%)(%)
61Sanitary Sewer Line A at Station 1+40FG-2.516129.5112.515.196
62Sanitary Sewer Line A at Station 1+41FG-2.016128.5111.914.896
63Sanitary Sewer Line A at Station 1+42FG-1.016130.6113.714.997
64Sanitary Sewer Line A at Station 1+43FG16131.4115.713.699
65Sanitary Sewer Line at Station 6+30FG-1.016132.9116.314.3100
66Sanitary Sewer Line at Station 6+31FG16132.1115.914.099
Non-compliant results are indicated by an asterisk(*) if
Gauge Information
applicable.
Serial No:399Manufacturer:HumboldtModel:5001EZStandard Count:(D):1921.6(M):475.3
Remarks:
Respectfully Submitted,
Technician:Shafi Abubeker
Start Time:
Stop Time:
Lunch Hrs:Total Hrs:Todd Smith
Version 1.9:
Date:3/1/18
This report is in general compliance with one or more of the following technical standards: D6938-15
Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA.
The use of our name and test results must receive our written
approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician
time is from portal to portal. MF-010(8/2/2016)
Geotechnical Engineering | Construction Materials Testing | Environmental Engineering