Wellington Place-CS 860103T E R ..... _R__. A
January 3, 1986
Mr. Wie Seng Lauw
Javatex Corporation
10400 N. Central Expressway
Suite 333
Dallas, Texas 75231
Dear Mr. Lauw:
We have reviewed the drainage plans for the Wellington Place
Addition prepared by McNamara Engineering Co. dated December 6,
1985. These plans call for runoff from the site to be discharged
at its northeast corner into a ditch which will take water north
along the westerly line of Riverchase into the existing ditch
which runs along the south side of Sandy Lake Road.
We agree to execute a drainage easement in favor of the City of
Coppell 15' wide in the east-west direction for the construction
of the 42" storm sewer pipe shown as line "A" on sheet C5, and
also agree to allow the construction of the drainage ditch shown
on sheet C7 with the following conditions:
1. Line "A" should be oriented due north and fitted with a
headwall.
2. The material excavated from the proposed ditch will be
compacted in accordance with the grading plan for Riverchase or
as directed by our engineer. Both the proposed ditch site and
the proposed fill site will be stripped of vegetation to a depth
of 6" prior to any filling. Fill will be compacted in loose
lifts of 8" or less to a density of at least 95% Standard Proctor
Density at a moisture content of between optimum and 5% above
optimum. Mike Daniel at Terra is to be contacted 72 hours prior
to the start of this activity.
3. Seventy-five feet of 60" storm sewer pipe with a flap
gate at the end should be installed in place of the proposed
ditch at its downstream end connecting to the ditch along Sandy
Lake Road. A standard City of Coppell headwall should be
installed at the outfall with a concrete headwall at the upstream
end. We will pay the difference in cost between the 60" system
and a comparable 42" system. This cost difference is to
Mr. Wie Seng Lauw
January 3, 1986
Page Two
be determined by asking for bids with the 60" system as an
alternate. The pipe should be placed 7.5' east of the west line
of Riverchase. We will execute a 15-foot wide easement to
accommodate the pipe.
4. The form of the easement must be acceptable to
Riverchase, and should include a provision allowing Riverchase to
grant other easements or privileges and make any use of the
easement area it desires so long as the use does not unreasonably
interfere with the rights granted by the easement.
5. You must agree to reimburse and indemnify Riverchase
for any claim, damage, liability, injury to person or property,
mechanics liens or other liens, and all expenses (including
attorneys' fees) attributable to your activities undertaken
pursuant to the easement. Further, we may require proof of
insurance satisfactory to us.
If you agree to these conditions, please indicate by signing in
the space below.
Sincerely,
RIVERCHASE JOINT VENTURE
By Terra Land Development Co.,
Venture Manager
;
/
~-~_~~a~terson, President
Accepted:
JAVATEX CORPORATION
Wie Seng L ,