CF-Coppell Rd SC-LR011102 (2) Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO,: 01.1054 CLIENT: Texas Unified Constructors, Inc. DATE: 2 November 2001 PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER: Lattimore LOCATION OF POUR SET 1: Piers on vehicle and equipment storage building: A/5.9, A/5, A/4, A/3, A/2, A/1.1, A.5/1.1, B/1.1, C/1.1, B.5/1.1, A.5/6 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 54 Truck No. 1106 Cement 414 Type I Ticket No. 3136203 Flyash 103 Time Batched 2:21 pm Sand 1433 Time Sampled 3:00pm in. Concrete Temp. (ASTM C1064) 78°F 1.0 in. 1850 Air Content (ASTM C231) Water 250 Unit Weight (ASTM C138) Admix #1 Plastocrete 161 @ 15.5 oz. Admix #2 AEA COMPRESS/VE STRENGTH TESTS {ASTM C39) (Standard 6 inch x 1 2 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 29 5.50 7 11/09/01 86,800 3070 30 5.50 28 11/30/01 114,900 4060 31 5.50 28 11/30/01 117,900 4170 32 5.50 56 12/28/01 28-Day Average 417~0 3000 TECHNICIAN: EWM DISTRIBUTION: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148