Gateway BP(1.4)-LR180405FLOOR FLATNESS TESTING REPORT
Report Number:94171346.0178
Service Date:04/05/18 8901 Carpenter Fwy Ste 100
Report Date:04/10/18 Dallas, TX 75247-4547
214-630-1010 Reg No: F-3272
Client Project
Haverty Furniture Co Inc Haverty's Warehouse Expansion
Attn: Glenn Boone 770 Gateway Blvd
780 Johnson Ferry Rd NE Ste 800 Coppell, TX 75019
Atlanta, GA 30342
Project Number: 94171346
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CT0001, 9-28-10, Rev.8 Page 1 of 2
Location Surveyed SOG, Placement 1, A – H / 1 - 4
Date of Placement 4/4/18
Approximate Area 28,500 square feet
ASTM Standard ASTM E 1155
Instrument Used Dipstick 2277, manufactured by Face Technologies
Sampling Method
Point elevations were measured at regular 12 inch intervals along 12 straight lines up to 97 feet
in length. The elevation differences between all adjacent reading points, the arithmetic
differences between all adjacent 12 inch elevation differences, and the elevation differences
between all points separated 10 feet were then calculated. Estimates of the floor's flatness and
levelness F-Numbers (FF and FL) were obtained through a statistical analysis of these
calculated profile values. See attached pages for individual measurement line results.
Overall Value (FF/FL)50 / 30
Specified Limits
Minimum Local Value (FF/FL)30 / 18
*Combined Flatness F-Number (FF)*Combined Levelness F-Number (FL)
51.33 ( 49.92 – 52.75 )33.96 (32.97 – 34.95 )Measured Results
*Based upon the number of samples taken, there is a 90% certainty that the actual F-Numbers of the surface surveyed
will fall within the ranges which follow the respective estimated Flatness and Levelness F-Numbers.
Comments:
FLOOR FLATNESS TESTING REPORT
Report Number:94171346.0178
Service Date:04/05/18 8901 Carpenter Fwy Ste 100
Report Date:04/10/18 Dallas, TX 75247-4547
214-630-1010 Reg No: F-3272
Client Project
Haverty Furniture Co Inc Haverty's Warehouse Expansion
Attn: Glenn Boone 770 Gateway Blvd
780 Johnson Ferry Rd NE Ste 800 Coppell, TX 75019
Atlanta, GA 30342
Project Number: 94171346
Services: Floor flatness/levelness testing.
Terracon Rep.: Mohammad Hassan
Reported To:
Contractor:
Report Distribution:
(1) Haverty Furniture Co Inc, Glenn
Boone
(1) City of Coppell TX, Marcus Marion
(1) Kajima Building & Design Group Inc., Craig Farwick (1) Kajima Building & Design Group Inc., Juan Hernandez Reviewed By:____________________________________
(1) Kent Companies, George Sellers (1) Macgregor Assoc Architects,
Muhammed Dikko Joel Warriner, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CT0001, 9-28-10, Rev.8 Page 2 of 2
2 4
A
H
N
127
109
6
5
4
3
2
1
8 11