Loading...
Gateway BP(1.4)-LR180213 (9)Report Number: Service Date: Report Date: Task: Client Coppell, TX 75019 770 Gateway Blvd Haverty's Warehouse ExpansionHaverty Furniture Co Inc Attn: Glenn Boone 780 Johnson Ferry Rd NE Ste 800 Atlanta, GA 30342 214-630-1010 Reg No: F-3272 Dallas, TX 75247-4547 8901 Carpenter Fwy Ste 100 94171346.0121 02/13/18 04/11/18 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94171346 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: R3136027 Martin Marietta Material Information 1259 6851 Plant: Ticket No.: 131 208823 Field Test Data Test Air Content (%): Result Specification 5 3 - 5 6.0 3 - 6 62 46 148.7 3,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:02/13/18 1330 Ali Kadhim Cloudy 10/80 10 Curb, W side of ApproachSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Approach & Curb at main entrancePlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 02/20/18 7 47,590 3 3,790 1 2 4.00 12.57 03/13/18 28 59,670 3 4,750 1 3 4.00 12.57 03/13/18 28 55,490 2 4,420 1 4 4.00 12.57 03/13/18 28 56,430 2 4,490 Average (28 days) 4,550 1 5 4.00 12.57 04/10/18 56 67,120 3 5,340 Initial Cure:Final Cure:Outside Moist Room Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) Haverty Furniture Co Inc, Glenn Boone (1) City of Coppell TX, Marcus Marion (1) Kajima Building & Design Group Inc., Craig Farwick (1) Kajima Building & Design Group Inc., Juan Hernandez (1) Kent Companies, George Sellers (1) Macgregor Assoc Architects, Muhammed Dikko Joel Warriner, P.E. Senior Project Manager Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Ali Kadhim The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6