Loading...
Gateway BP(1.4)-LR180510 (3)MORTAR COMPRESSIVE STRENGTH TEST REPORT Report Number: Service Date: Report Date: Task: Client 94171346.0236 05/10/18 05/21/18 8901 Carpenter Fwy, Ste 100 Dallas, TX 75247-4547 214-630-1010 Reg No: F-3272 Haverty Furniture Co Inc Attn: Glenn Boone 780 Johnson Ferry Rd NE Ste 800 Atlanta, GA 30342 Coppell, TX 75019 770 Gateway Blvd Haverty's Warehouse Expansion Project Project Number: 94171346 psi @ days Mix ID: Supplier: Batch Time: Material Information Plant: Field Test Data Test Mortar Temp. (F): Ambient Temp. (F): Result Specification 28 SpecMix C & B Masonry 1530 On-site 82 86 Specified Strength: 2,500 Sample Information Sample Date: Sampled By: Weather Conditions: Sample Size: Sample Location: Sample Time:05/10/18 1545 Scooter Day Clear 2 x 2 x 2 See Placement Location Placement Location:H.9-G/8-8.2 Test Mold Material: Curing Procedure: Brass ASTM C 780 Laboratory Test Data No. Date Age Area (lbs) Load Strength Compressive ID Received Date Tested (days)(sq in)(psi) Maximum Set Specimen Tested By 1 1 05/17/18 7 4.00 14,255 3,560 1 2 05/17/18 7 4.00 14,565 3,640 1 3 05/17/18 7 4.00 14,185 3,550 Average (7 days) 3,580 1 4 06/07/18 28 1 5 06/07/18 28 1 6 06/07/18 28 Initial Cure:Outside Final Cure:Moist Room Comments: Note: The indicated Specified Strength above is for laboratory batched and cast specimens under controlled conditions. Strength tests of field cast specimens are to be used to monitor trends and batch to batch consistency of mortar per ASTM C 270 and are not intended as criteria to determine the acceptance or rejection of the mortar as installed. Samples Made By: Terracon Obtain a sample of masonry mortar used during construction and cast 2 inch cube specimens for compressive strength determination. Services: Reported To: Contractor: Report Distribution: (1) Haverty Furniture Co Inc, Glenn Boone (1) City of Coppell TX, Marcus Marion (1) Kajima Building & Design Group Inc., Craig Farwick (1) Kajima Building & Design Group Inc., Juan Hernandez (1) Kent Companies, George Sellers (1) Macgregor Assoc Architects, Muhammed Dikko Senior Project Manager Joel Warriner, P.E. Reviewed By: ASTM C109Test Methods: Terracon Rep.: Scooter Day The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0008, 11-16-12, Rev.6 Page 1 of 1