Gateway BP(1.4)-LR180517REINFORCING STEEL OBSERVATIONS REPORT
Report Number:94171346.0243
Service Date:05/17/18 8901 Carpenter Fwy, Ste 100
Report Date:05/21/18 Dallas, TX 75247-4547
214-630-1010 Reg No: F-3272
Client Project
Haverty Furniture Co Inc Haverty's Warehouse Expansion
Attn: Glenn Boone 770 Gateway Blvd
780 Johnson Ferry Rd NE Ste 800 Coppell, TX 75019
Atlanta, GA 30342
Project Number: 94171346
Services: Reinforcing steel (rebar) placement observation.
Terracon Rep.: Jonathan Baze
Reported To:
Contractor:
Report Distribution:
(1) Haverty Furniture Co Inc, Glenn
Boone
(1) City of Coppell TX, Marcus Marion
(1) Kajima Building & Design Group Inc., Craig Farwick (1) Kajima Building & Design Group Inc., Juan Hernandez Reviewed By:____________________________________
(1) Kent Companies, George Sellers (1) Macgregor Assoc Architects,
Muhammed Dikko Joel Warriner, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
R940003, 03/10/17, Rev.1 Page 1 of 1
PROJECT DATA
Drawings Utilized:N/A #3’s @ 18” OCEW/ Smooth, greased dowels and dowels into existing concrete in place
Locations/Items Observed: All sidewalk along Gateway From Fritz Dr to Opposite entrance
Test Method:Visual Observation
REPORT OF OBSERVATION
ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT
Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type
Bar Size X Proper Bar Placement X Stirrup Spacing & Type
Bar Grade X Properly Tied X Welded Splices
Rebar Clean X Dowel Bars in Place X Mechanical Splices
Trash & Debris Removed X Proper Bar Supports X Lapped Splices x
Number of Bars X Proper Cover/Clearance X
Discrepancies/Comments:
No discrepancies were noted at the time of this observation.