Loading...
Gateway BP(1.4)-LR180608 (2)Report Number: Service Date: Report Date: Task: Client Coppell, TX 75019 770 Gateway Blvd Haverty's Warehouse ExpansionHaverty Furniture Co Inc Attn: Glenn Boone 780 Johnson Ferry Rd NE Ste 800 Atlanta, GA 30342 214-630-1010 Reg No: F-3272 Dallas, TX 75247-4547 8901 Carpenter Fwy, Ste 100 94171346.0253 06/08/18 07/09/18 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94171346 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: F8233M Martin Marietta Material Information 1055 3856 Plant: Ticket No.: 131 4761279 Field Test Data Test Air Content (%): Result Specification 4 1/2 3 - 5 3.2 3 - 6 93 88 130.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:06/08/18 1203 Jason Carrizales Clear 10 10 5 0 See Placement LocationSample Location: Placement Method:Bucket Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Elevated Topping Slab on Electrial Room & Office. Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested By 1 1 4.00 12.57 06/15/18 7 63,885 2 5,080 ZHG 1 2 4.00 12.57 07/06/18 28 77,115 1 6,140 ZHG 1 3 4.00 12.57 07/06/18 28 74,635 1 5,940 ZHG 1 4 4.00 12.57 07/06/18 28 75,945 1 6,040 ZHG Average (28 days) 6,040 1 5 08/03/18 56 Initial Cure:Final Cure: Comments:Average compressive strength of 28 day cylinders complies with the specified strength. see report # 0252 for miles Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) Haverty Furniture Co Inc, Glenn Boone (1) City of Coppell TX, Marcus Marion (1) Kajima Building & Design Group Inc., Craig Farwick (1) Kajima Building & Design Group Inc., Juan Hernandez (1) Kent Companies, George Sellers (1) Macgregor Assoc Architects, Muhammed Dikko Joel Warriner, P.E. Senior Project Manager Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 BD000L, 08-24-13, Rev.1 Site Plan:Haverty's Warehouse Expansion Report Number: 94171346.0253 770 Gateway Blvd Technician: Jason Carrizales 8901 Carpenter Fwy, Ste 100 Coppell, TX 75019 Date: 06/08/18 Dallas, TX 75247-4547 Scale:Not to Scale 214-630-1010 Reg No: F-3272 BD000L, 08-24-13, Rev.1 Site Plan:Haverty's Warehouse Expansion Report Number: 94171346.0253 770 Gateway Blvd Technician: Jason Carrizales 8901 Carpenter Fwy, Ste 100 Coppell, TX 75019 Date: 06/08/18 Dallas, TX 75247-4547 Scale:Not to Scale 214-630-1010 Reg No: F-3272 BD000L, 08-24-13, Rev.1