Freeport NIP(2.2)-LR011206CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0074 8901 Carpenter Frwy., Suite #100 Service Date: November 27, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3600 psi (~ 28 Days Sample Time: 7:16am Date Cast: November 27, 2001 Technician: Barry Cuble Batch Time: 6:05am Plant: 41 Weather Conditions: Cloudy, cool, windy Supplier: TXI Accumulative Yards: 40 Truck No: 837 Ticket No: 3030874 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See placement location Water Added Onsite Before Test: 10 Gallons Placement Location: Paving- N firelane & parking, bldg. slab leaveout: Lines A/3-6 Sample location: 12' S of N curb, 25' E of Royal Lane (See attached sketch) Field Test Data Test Result Specification Test Method Slump, inches: 5.75 3-5 ASTM C-143 Air Content, %: 5.1 3-6 ASTM C-231 Concrete Temperature, o F: 59 ASTM C1064 Ambient Temperature, o F: 40 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 12/04/2001 7 108,340 3,830 1 2 6.00 28.27 12/04/2001 7 109,700 3,880 Average 3,860 1 3 12/25/2001 28 1 4 12/25/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 °'-~w~°'~c=°~W CONCRETE COMPRESSIVE STRENGTH TEST ~IN~, INC. Report Number: 94011204.0074 sgot Carpenter Frwy., Suite #100 Service Date: November 27, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3600 psi @ 28 Days Sample Time: 8:09am Date Cast: November 27, 2001 Technician: Barry Cuble Batch Time: 7:35am Plant: 41 Weather Conditions: Partly cloudy, cool, windy Supplier: T×I Accumulative Yards: 90 Truck No: 65 Ticket No: 3030989 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See placement location Placement Location: See page 1 Sample location: 120' E of W, 30'N ors curb Field Test Data Test Result Specification Test Method Slump, inches: 5.50 3-5 ASTM C-143 Air Content, %: 3-6 ASTM C-231 Concrete Temperature, o F: 59 ASTM C1064 Ambient Temperature, o F: 40 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 12/04/2001 7 107,800 3,810 2 2 6.00 28.27 12/04/2001 7 106,710 3,770 Average 3,790 2 3 12/25/2001 28 2 4 12/25/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o,-~w,~o,-F~,~ Page 2 of 5 i "ir"',~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0074 8901 Carpenter Frwy., Suite #100 Service Date: November 27, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3600 psi @ 28 Days Sample Time: 10:13am Date Cast: November 27, 2001 Technician: Barry Cuble Batch Time: 8:19am Plant: 41 Weather Conditions: Cloudy, cool Supplier: TXI Accumulative Yards: 140 Truck No: 68 Ticket No: 3031046 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: 25' N of S curb, 15' W of E Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 5.2 3-6 ASTM C-231 Concrete Temperature, o F: 59 ASTM Cl 064 Ambient Temperature, o F: 39 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 12/04/2001 7 96,110 3,400 3 2 6.00 28.27 12/04/2001 7 94,710 3,350 Average 3,380 3 3 12/25/2001 28 3 4 12/25/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 CONCRETE COMPRESSIVE STRENGTH TEST ~'"'i~ Report Number: 94011204.0074 89Ol Carpenter Frwy., Suite #100 Service Date: November 27, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3600 psi @ 28 Days Sample Time: 11:44am Date Cast: November 27, 2001 Technician: Barry Cuble Batch Time: 8:54am Plant: 41 Weather Conditions: Cloudy, cool, light winds Supplier: TXI Accumulative Yards: 180 Truck No: 836 Ticket No: 3031100 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See placement location Placement Location: See page 1 Sample location: 20' N of S curb, 10' E of bldg. Field Test Data Test Result Specification Test Method Slump, inches: 4.50 3-5 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature,o F: 63 ASTM C1064 Ambient Temperature, 0 F: 39 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 12/04/2001 7 108,310 3,830 4 2 6.00 28.27 12/04/2001 7 113,360 4,010 Average 3,920 4 3 12/25/2001 28 4 4 12/25/2001 28 Note: Loads 150-180 were placed @ 2 1/2 hours old, contractor notified of time, temperature & slump prior to placement. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical · materials. Page 4 of 5 O._Lw~o,-F~o CONCRETE COMPRESSIVE STRENGTH TEST ENGINEF. PdNG, [~C. Client: TNA North American, Inc. Project Number:94011204 Report Number: 94011204.0074 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Barry Cuble /////'J/ Report Distribution: Z~~/~ring, Inc. (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Pccle & Yost Architecture (1) David Kent Reviewed by: (1) R L Good.son Consulting Engineers (1) City of Coppell- Bldg Insp Eric J. ClevL,,land, P.E. (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 o,.~w,.o, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0055 8901 Carpenter Frwy., Suite #100 Service Date: November 6, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Da_t~ Attn: Terry Raley ProJect warehouse 1321 Valwood Parkway, Suite 440 Carrollton TX 75006~ - O~'~-~ Project Number: 94011204 Material Informati Sample Information Specified Strength: 3500 ~si @ 28 Days ~ I Sample Time: 8:10am Date Cast:November 6, 2001  Technician: Jason Kale Batch Time: 7:23am Plant: 41 [~'!E' I·1~ Weather Conditions: Clear Supplier: TXI ~' {" Accumulative Yards: 10 Truck No: 928 Ticket No: 3017509 Placement Method: Direct Discharge Mix I.D. No.: 8273 ~ Sample Locations: See placement location Water Added Onsite Before Test: 20 Gallons ~' ~ent Location: Paving, see attached sketch Water Added Onsite After Test: 5 Gallons Field Test Data Test Result Specification Test Method Slump, inches: 5.50 3-5 ASTM C-143 Air Content, %: 3-6 Concrete Temperature, o F: 74 ASTM C1064 Ambient Temperature, 0 F: 60 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/13/2001 7 96,780 3,420 1 2 6.00 28.27 11/13/2001 7 97,790 3,460 Average 3,440 1 3 6.00 28.27 12/04/2001 28 121,760 4,310 1 4 6.00 28.27 12/04/2001 28 120,210 4,250 Average 4,280 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 o,~_w~,-~.~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0055 8901 Carpenter Frwy., Suite #100 Service Date: November 6, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3500 psi @ 28 Days Sample Time: 8:45am Date Cast: November 6, 2001 Technician: Jason Kale Batch Time: 7:56am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 10 Truck No: 660 Ticket No: 3017632 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 3-6 Concrete Temperature, o F: 73 ASTM C1064 Ambient Temperature, o F: 62 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 I 6.00 28.27 11/13/2001 7 105,370 3,730 2 2 6.00 28.27 11/13/2001 7 102,030 3,610 Average 3,670 2 3 6.00 28.27 12/04/2001 28 127,860 4,520 2 4 6.00 28.27 12/04/2001 28 130,690 4,620 Ave rage 4,570 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 o,-~w,~o, · CONCRETE COMPRESSIVE STRENGTH TEST ~1_~ Report Number: 94011204.0055 ~,~.~,~c. 8901 Carpenter Frwy., Suite #100 Service Date: November 6, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 06, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3500 psi (~ 28 Days Sample Time: 11:00am Date Cast: November 6, 2001 Technician: Jason Kale Batch Time: 8:58am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 10 Truck No: 922 Ticket No: 3017749 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See page Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 3.25 3-5 ASTM C-143 Air Content, %: 3-6 Concrete Temperature, o F: 81 ASTM C1064 Ambient Temperature, o F: 79 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 11/13/2001 7 109,420 3,870 3 2 6.00 28.27 11/13/2001 7 105,950 3,750 Average 3,810 3 3 6.00 28.27 12/04/2001 28 123,570 4,370 3 4 6.00 28.27 12/04/2001 28 124,670 4,410 Ave rage 4,390 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Report Distribution: . (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by: (1) R L Goodson Consulting Engineers (1) City of Coppell - Bldg Insp ~x' L~cj. Clev/~land, P.E. (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Proj~ct Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th~ use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3