Freeport NIP(2.2)-LR011010 (2) CONCRETE COMPRESSIVE STRENGTH TEST
Repo~r:f ,,,u,,,u~, 94011204..0040 8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Se_r~ce Date:" Octo/, 2001 (214) 630-1010
Cl~'nt:__ TNA North A~ican, Inc. Report Date: October 10, 2001
~ Attn: Ter~,ll~aley Project: Sales Office & Warehouse Fac.
~, 1321 V~f~,ood Parkway, Suite 440 Coppell, Texas
'~~ton TX 75006
Pr~oject Number: 94011204
Material Information s~ Sample Information
Specified Strength: 3000 psi @ 28 Day Sample Time: 3:21 pm Date Cast: October 2, 2001
Technician: Marlo Garcia
Batch Time: 2:16pm Plant: 31 Weather Conditions: Warm and sunny w/slight breeze
Supplier: TXI Accumulative Yards: 50
No: 2992441
Truck No: 46 Ticl~t Placement Method: Direct Discharge
Mix I.D. No.: 9506 Sample Locations: Pier B/1
Placement Location: Piers D/6.5, B/l, A.7/1 & AJ1.4
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.00 5-7 ASTM C-143
Air Content, %:
Concrete Temperature, o F: 86 ASTM C1064
Ambient Temperature, o F: 86 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 10/09/2001 7 85,710 3,030
I 2 6.00 28.27 10/09/2001 7 89,600 3,170
Ave rage 3,100
1 3 10/30/2001 28
I 4 10/30/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Marlo Garcia
Report Distribution: //~~/~ Inc.
(1) TNA NoAh American, Inc. (1) FACServices Inc
(1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by: ,._~~
(1) R L Goedson Consulting Engineers (1) City of Coppell - Bldg Insp ~/'lE~ic J. .... Cl'~veland, P.E
(1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 o~ ..,.,~.~,.