Petterson (Encore)-LR180816
Alpha Testing, Inc.
2209 Wisconsin St.
Concrete Compression Test
Dallas, TX 75229
(972)620-8911
Report
TBPE Firm No. 813
RECH COPPELL, LLC08/16/2018
Tested For:Date Issued:
ATTN:MATT MILDREN
173166-26
Our Report #:
4145 TRAVIS STREET, SUITE 202
DALLAS, TX 75204
TODD SMITH
PM:
Fax Number:
PETTERSON ADDITION - ENCORE OF COPPELL
Project Desc:
TIERRA GRANDE WAY AND SANDY LAKE ROAD
FIELD DATA
PAVING: AIDAN'S COURT FROM STATION 3+19.90 TO 0+38.80
Placement Location:
@ STATION 2+54
Sample Location:
7/19/2018LMC
Date Placed:Concrete Supplier:
11:10 AM950
Time Placed:Plant Number:
63030687
ALPHADelivery Ticket No.:
Cast By:
10:07:00 AM
Batch Time:
Result
1701
Mix ID:
89
Concrete Temp (F):
Lane, William
Submitted By:
4.0
Slump (ASTM C-143):
7/20/2018
Date Received:
5.0
(ASTM C-173)
Air Content:
ASTM C-31
Cured Specification:
95
Ambient Temp (F):
3600
Specified Strength:
N/A
Unit Weight:
CYLINDER COMPRESSION TEST RESULTS
LabCureBreakCapDateAgeAvg.Avg.Avg Depth/Area:Max
PSI:
No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load:
217/26/2018712.56528224210
LAB3C-12318N/A4
22LAB3C-12318/16/2018288N/A412.56670505340
23LAB2C-12318/16/2018288N/A412.56567324520
24LAB2C-12318/16/2018288N/A412.56604304810
Average 28-day Compressive Strength is compliant with project specifications
4890
PMB Capital Investments, Clay Moore Engineering, City of Coppell, City of Coppell
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc.
Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM
C39.
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting327564
Alpha Testing, Inc.
2209 Wisconsin St.
Concrete Compression Test
Dallas, TX 75229
(972)620-8911
Report
TBPE Firm No. 813
RECH COPPELL, LLC08/16/2018
Tested For:Date Issued:
ATTN:MATT MILDREN
173166-27
Our Report #:
4145 TRAVIS STREET, SUITE 202
DALLAS, TX 75204
TODD SMITH
PM:
Fax Number:
PETTERSON ADDITION - ENCORE OF COPPELL
Project Desc:
TIERRA GRANDE WAY AND SANDY LAKE ROAD
FIELD DATA
PAVING: AIDAN'S COURT FROM STATION 3+19.90 TO 0+38.80
Placement Location:
@ STATION 1+00
Sample Location:
7/19/2018LMC
Date Placed:Concrete Supplier:
2:00 PM956
Time Placed:Plant Number:
7684906
ALPHADelivery Ticket No.:
Cast By:
12:54:00 PM
Batch Time:
Result
1701
Mix ID:
95
Concrete Temp (F):
Lane, William
Submitted By:
4.5
Slump (ASTM C-143):
7/20/2018
Date Received:
4.6
(ASTM C-173)
Air Content:
ASTM C-31
Cured Specification:
100
Ambient Temp (F):
5000
Specified Strength:
N/A
Unit Weight:
CYLINDER COMPRESSION TEST RESULTS
LabCureBreakCapDateAgeAvg.Avg.Avg Depth/Area:Max
PSI:
No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load:
257/26/2018712.56586964670
LAB2C-12318N/A4
26LAB2C-12318/16/2018288N/A412.56628875010
27LAB2C-12318/16/2018288N/A412.56698905560
28LAB2C-12318/16/2018288N/A412.56671105340
Average 28-day Compressive Strength is compliant with project specifications
5300
PMB Capital Investments, Clay Moore Engineering, City of Coppell, City of Coppell
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc.
Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM
C39.
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting327565