Loading...
Petterson (Encore)-LR180831 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 RECH COPPELL, LLC08/31/2018 Tested For:Date Issued: ATTN:MATT MILDREN 173166-33 Our Report #: 4145 TRAVIS STREET, SUITE 202 DALLAS, TX 75204 TODD SMITH PM: Fax Number: PETTERSON ADDITION - ENCORE OF COPPELL Project Desc: TIERRA GRANDE WAY AND SANDY LAKE ROAD FIELD DATA SIDEWALK: SANDY LAKE RD. Placement Location: 3'N & 15'E OF TIERRA GRANDE WAY Sample Location: 8/24/2018LMC Date Placed:Concrete Supplier: 1:45 PM956 Time Placed:Plant Number: 76849856 ALPHADelivery Ticket No.: Cast By: 1:06:00 PM Batch Time: Result 1261 Mix ID: 96 Concrete Temp (F): Kopplin, Randy Submitted By: 3.75 Slump (ASTM C-143): 8/25/2018 Date Received: 3.9 (ASTM C-231) Air Content: ASTM C-31 Cured Specification: 95 Ambient Temp (F): 3000 Specified Strength: 148.5 Unit Weight: CYLINDER COMPRESSION TEST RESULTS LabCureBreakCapDateAgeAvg.Avg.Avg Depth/Area:Max PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 418/31/2018712.56383103050 LAB2C-12318N/A4 42LABC-12319/21/2018288N/A412.560 43LABC-12319/21/2018288N/A412.560 44LABC-12319/21/2018288N/A412.560 PMB Capital Investments, Clay Moore Engineering, City of Coppell, City of Coppell CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting332426