Windsor Estates-LR000829 ..--07-' CP!~:5C t?C~ '
1341 Wes-'. Mockingbird Lane · Dallas, Texas 75247 · 972.647.6700 · www. txi.com
.ooo "vii:*
Austin Bridge & Road
11143 Goodnight Lane
Dallas, TX 75229
RE: Windsor Estates
DeForest - Coppell
8204SF 8206
The attached concrete mix designs utilizing the appropriate ASTM
C-33 or ASTM C-330 aggregate are proposed for use on the above
referenced project for ready-mixed concrete to be furnished by
TXI.
To ensure that the correct mix is delivered to your project,
please order by the mix design number which appears in the upper
left hand corner of the mix design.
Texas Industries certifies that the above mix designs, when
ordered by specified design identity, and delivered by TXI, will
meet or exceed the indicated design strength at the designated
age when tested in accordance with the applicable and current
ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable
provisions of C 94, and evaluated in accordance with applicable
provisions of ACI Building Code.
TXI would like to be included on your mailing list to receive all
test reports. ASTM C 94 entitles a manufacturer to receive
copies of all test reports when strength of concrete is used as a
basis for acceptance.
Please contact us if you have any questions or require any
additional information. Please notify TXI of approval of the
proposed mix designs prior to their use. Failure to notify us
prior to first placement shall constitute acceptance. To ensure
that the proper mix designs are ordered, please send a copy of
this letter, after approval, to the above referenced project to
be used by the person ordering the concrete for this job.
Sincerely,
Manager-Q.A./Q.C.
Mix #: 8204SF
Description: 470# ADMIX/AEA I"CS
Strength: 3000 psi @ 28 Days
SLIP FORM PAVING
Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE
Maximum Water/Cement Ratio: 5.52 gal/sack or 0.515 lbs/lb
Cement/Cementitious Content: 5.25 sacks (per cubic yard)
Maximum Placement Slump: 3.00 inches
Air Entraining Agent: ASTM C-260
Admixture: ASTM C-494 Type A or D
MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D
376 lbs. ASTM C 150 TYPE I CEMENT
94 lbs. ASTM C 618 FLY ASH
1840 lbs. 1" - #4 CRUSHED STONE
1378 lbs. CONCRETE SAND
242 lbs. or 29.0 Gallons of Water
2.0 to 4.0 oz/cwt of ASTM C-494 Type D
Specified Air Content: 3.0% - 6.0%
Placement Slump: 2.00 + or - 1.00 inches
Mix #: 8206
Description: 564~ ADMIX/AEA I"CS
Strength: 4000 psi @ 28 Days
HAND PLACED PAVING
Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE
Maximum Water/Cement Ratio: 4.91 gal/sack or 0.457 lbs/lb
Cement/Cementitious Content: 6.31 sacks (per cubic yard)
Maximum Placement Slump: 4.00 inches
Air Entraining Agent: ASTM C-260
Admixture: ASTM C-494 Type A or D
MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D
451 lbs. ASTM C 150 TYPE I CEMENT
113 lbs. ASTM C 618 FLY ASH
1840 lbs. 1" - #4 CRUSHED STONE
1254 lbs. CONCRETE SAND
258 lbs. or 31.0 Gallons of Water
2.0 to 4.0 oz/cwt of ASTM C-494 Type D
Specified Air Content: 3.0% - 6.0%
Placement Slump: 3.00 + or - 1.00 inches
PUMPING NOTES / RECOMMENDATIONS
1. 5" minimum diameter lines with no reduction to smaller
lines.
2. Keep rubber hose to absolute minimum length and plan pipe
with as few 90 degree angles as possible.
3. Samples for slump and strength tests should be taken @
discharge end of hose for strength guarantee to be valid.
4. To prime pump lines, a minimum of 8.0 sack grout should be
used for lubrication. In the case of strength concrete,
equivalent strength grout should be used if the grout
remains in the placement.
5. Pump mixes are based on minimum cement content pumped at
ground level. As pump line increases in length or height
and/or layout configuration changes, mix design
modifications may be required to assure strength and
pumpability at additional cost to the contractor.
6. TXI cannot control, and is therefore not responsible for
excessive loss of entrained air content when loss occurs as
a result of boom configuration or free fall discharge from
hose. To ensure minimum air loss when pumping, maintain a
continuous flow of concrete through the entire length of
pipe and do not subject concrete to free fall.
7. The term "pumpable concrete" refers to concrete which is
capable of being transported through an apparatus which
forces concrete to the placing position through a pipeline
or hose as long as the recommendations indicated above are
followed. The term "pumpable concrete" does not relate to
concrete proportioned in a particular manner or containing a
specific type of product.
Unless otherwise indicated, when the concrete temperature at
point of placement exceeds 90 degrees Fahrenheit, TXI will
guarantee the strength performance of the mix design(s) herein
submitted up to a maximum placement temperature of 100 degrees
Fahrenheit using an ASTM C 494 Type D retarding water-reducer, as
long as the concrete is placed within 75 minutes from batch time.
Unless otherwise indicated, strength of plain concrete guaranteed
up to a maximum placement temperature of 85 degrees Fahrenheit.
We are enclosing all available back up data for the referenced
mix design(s). If the strength information is not available, or
is insufficient, confirmation tests may have to be conducted by
your laboratory.
Strength of lightweight mix designs valid provided strength
specimens are cured in accordance with ASTM Test Method C 567, as
referenced in section 8.1 of ASTM Specification C 330.
TEXAS TKDUSTRXES
CON~Z DESIG~T ~V~J~UATION
D&te: 08/29/00 *' St&t~st~cs C~led F~ ~ndepe~ent ~o~&to~ Test
~x ~e~: 8204~ Streng~: 3000 ~.~
28 Day Teat
TesC Plant (Fakrenkeit) Placement Percen: ......... 28 Day ........ Cumulative Moving
Nu.-aber Date Number Ambient Concrete Slump{in) of Air PSI 1 PSI 2 PSI Av~ Average Avg of 3 Range
I 03/17/99 35 65 69 2.00 4.8% 4510 4640 4575 4575 130
2 04/16/99 12 65 68 3.00 3.5% 6440 6680 6560 5568 240
3 G4/16/99 12 S2 56 3.00 4.9% 5010 4890 4950 5362 5362 120
4 06/24/99 12 81 85 3.00 3,14 4900 4980 4940 5256 5483 80
5 06/24/99 12 86 88 3.00 3.14 5560 5610 5585 5322 5158 50
6 06/24/99 12 86 88 3.00 3,0% 4750 4640 4695 5218 5073 110
7 06/24/99 12 86 88 2.25 3.4% 5360 5470 5415 5246 5232 119
8 06/28/99 12 95 87 1.75 5.04 4760 4690 4725 5181 4945 70
9 06/28/99 12 90 85 2.00 5.5% 4940 5020 4980 5158 5040 87
10 06/28/99 12 85 85 2.50 5.0% 4860 4540 4750 5118 4818 220
11 07/22/99 !2 85 90 2.00 5.2% 4360 4410 4385 5051 4705 5~
12 07/22/99 12 76 88 2.00 4.8% 4440 4300 4370 4994 4502 140
13 07/22/99 12 88 91 2.25 5.0% 4760 4780 4770 4977 4508 20
14 07/22/99 12 74 86 2.75 4.5% 4590 3960 4025 4909 4388 130
15 08/12/99 97 2.75 4.0% 4300 4320 4310 4869 4368 2~
!6 08/12/99 96 2.50 4.2% 4490 4360 4380 4838 4238 40
17 08/19/99 97 3.00 4.7% 4470 4250 4360 4810 4350 229
IB 09/28/99 35 89 88 3.00 5.14 5190 5110 5150 4829 4633 80
19 09/29/99 35 74 85 2.00 4.7% 5070 5430 5250 4851 4920 360
20 09/29/99 35 65 82 3.00 5.14 5450 4790 5120 4865 5173 66D
21 09/29/99 35 63 75 2.25 2.0% 5440 5090 5265 4884 5212 350
22 12/17/99 12 60 38 2.00 5.0% 5280 4940 5110 4894 5165 34~
23 12/17/99 12 36 45 3.00 6.0% 5170 4740 4955 4897 5113 430
24 01/06/00 12 55 57 3.00 4.4% 5670 5750 5710 4931 5258 80
25 01/31/00 12 39 48 3.00 6.0% 5140 5110 5125 4938 5263 30
26 03/07/00 43 68 76 3.00 4.04 5400 5220 5310 4953 5382 180
27 03/07/&0 43 63 71 3.00 3.5% 5360 5520 5440 4971 5292 160
28 03/08/00 21 70 81 3.00 4.14 4050 4110 4080 4939 4943 60
29 03/13/00 21 61 70 3.00 4.0% 5560 5480 5520 4959 5013 8'D
30 03/15/C0 21 64 73 3.00 4.0% 6410 6530 6470 5009 5357 12~
*** Averages *** 71 78 2.63 4.4%
COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS
Mix Num: 82045~ Strength: 3000 psi @ 28 Days
Paragraph 5.5 of ACI 318-95 provides that as data becomes
available during construction, the amount by which (P'cr) must
exceed the specified value of (F'c) may be reduced, provided:
(a) 30 or more test results are available and average of
test results exceeds that required by Section 5.3.2.1,
using a standard deviation calculated in accordance
with Section 5.3.1.1, or
(b) 15 to 29 test results are available and average of test
results exceeds that required by Section 5.3.2.1, using
a standard deviation calculated in accordance with
Section 5.3.1.2.
The required average compressive strensth has been calculated
using a standard deviation calculated in accordance with
ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger
value of these calculations:
F'cr = F'c + 1.34(SD)
= 3000 + 1.34( 607.0)
= 3813
F'cr = F'c + 2.33(SD) - 500
= 3000 + 2.33( 607.0) - 500
= 3914
SUMMARY OF STATISTICAL ANALYSIS
28 Day Test Data
Number of Tests .......................... 30
Maximum Value ............................ 6560 psi
Minimum Value ............................ 4025 psi
Range .................................... 2535 psi
Average Strength ......................... 5009 psi
Standard Deviation ....................... 607 psi
Required Average Strength to satisfy
minimum probability conditions of
ACI 318-89 Section 5.3.2.1 ............... 3914 psi
Design excess beyond code requirements... 1095 psi
TEXA~ INDUSTRIES
CONCRETE DESIGN ~VALUATION
Date: 08/29/00 ** Statistfcs Co=~iled Fr~ Independent Laboratory Test Spec~ns **
~x ~er: 8206 Streng~: 4000 psi · 28 Days
Test Plant (Fahre~heit) Placement Percent ......... 28 Day ........ Cumulative Moving
Number Date Number Ambient Concrete Slump(in) of Air PSi 1 PSI 2 PSI Avg Average Avg of 3 Range
1 04/06/00 78 86 4.50 4.7% 6050 6440 6250 6250
2 04/06/00 65 73 4.25 N/A 4770 4950 4860 5555
3 04/06/09 68 77 5.50 4.8% 4960 5150 5055 5388 5388 190
4 04/06/00 62 69 3.75 N/A 5960 6070 6015 5545 5310 110
5 04/14/00 59 66 4.50 N/A 5440 5330 5385 5513 5485 110
6 04/14/00 62 83 4.50 4.3% 4150 4390 4270 5306 5223 240
7 04/17/00 61 76 4.25 N/A 5580 5550 5565 5343 5073 30
8 04/18/00 80 81 4.75 4.5% 4750 4510 4630 5254 4822 240
9 05/11/00 74 87 3.75 4.9% 5720 5250 5485 5279 5227 470
10 05/11/00 8~ 88 3.50 4.9% 5140 4860 5000 5252 5038 289
11 05/11/00 70 82 4.25 5.14 4620 4750 4685 5200 5057 130
12 05/11/90 71 80 2.75 4.6% 5130 5170 5150 5196 4945 40
13 05/12/09 75 87 3.00 4.2% 5350 5670 5515 5220 5117 310
14 05/12/00 76 86 5.50 2.0% 529D 5430 5360 5230 5342 140
15 05/12/~0 74 87 3.75 4.0% 5800 6220 601~ 5282 5618
16 05/12/00 74 89 2.75 4.0% 6020 5910 5965 5325 5778 110
17 05/12/00 71 81 4.00 4.5% 4070 4420 4245 5261 5497 350
18 05/15/09 65 81 2.00 5.2% 5520 5700 5610 5281 5273 180
19 05/15/00 63 74 4.00 8.0% 4750 4830 4790 5255 4882 80
20 05/15/00 64 76 5.75 8.0% 4490 4790 4640 5224 5013 3C0
21 05/15/00 64 74 3.00 11.04 5220 5290 5255 5226 4895 70
22 05/15/00 62 74 2.50 9.5% 5290 5510 5400 5234 5098 220
23 05/16/00 84 89 4.50 5.0% 4950 4760 4855 5217 5170 190
24 05/16/00 72 86 4.25 5.7% 4630 4680 4655 5194 4970 50
25 05/18/00 88 92 4.50 5.2% 5130 5i20 5125 5191 4878 i0
26 05/22/00 75 89 3.50 5.6% 6100 6050 6075 5225 5285
27 05/22/00 73 83 4.25 5.14 5590 5490 5549 5237 5580
28 05/22/00 83 89 4.75 4.7% 5210 5420 5315 5239 5643 210
29 05/22/00 71 82 8.0~ 5.8% 4320 4340 4330 5208 5062 20
30 05/25/02 97 95 3.50 4.8% 5130 5330 5230 5209 4958 220
*** Averages *** 72 82 4.13 5.4%
COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS
Mix Num: 8206 Strength: 4000 psi @ 28 Days
Paragraph 5.5 of ACI 318-95 provides that as data becomes
available during construction, the amount by which (F'cr) must
exceed the specified value of (F'c) may be reduced, provided:
(a) 30 or more test results are available and average of
test results exceeds that required by Section 5.3.2.1,
using a standard deviation calculated in accordance
with Section 5.3.1.1, or
(b) 15 to 29 test results are available and average of test
results exceeds that required by Section 5.3.2.1, using
a standard deviation calculated in accordance with
Section 5.3.1.2.
The required average compressive strength has been calculated
using a standard deviation calculated in accordance with
ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger
value of these calculations:
F'cr = F'c + 1.34(SD)
= 4000 + 1.34( 547.5)
= 4734
F'cr = F'c + 2.33(SD) - 500
= 4000 + 2.33( 547.5) - 500
= 4776
SUMMARY OF STATISTICAL ANALYSIS
28 Day Test Data
Number of Tests .......................... 30
Maximum Value ............................ 6250 psi
Minimum Value ............................ 4245 psi
Range .................................... 2005 psi
Average Strength ......................... 5209 psi
Standard Deviation ....................... 548 psi
Required Average Strength to satisfy
minimum probability conditions of
ACI 318-89 Section 5.3.2.1 ............... 4776 psi
Design excess beyond code requirements... 433 psi
~e MIDLOTHIAN CEMENT PLANT · 245 Ward Road · Midlothian, Texas 76065 · www.txi.com
SPECIFICATIONS
Portland Cement
Type 1/11 (Low Alkali)
A.S.T.M. C150-98
Bin Number
Car Number
'Tons
Date of Sampling July-2000 Monthly Average
ASTM I TEST
SPECIFICATION RESULTS
CHEMICAL REQUIREMENTS
Silica Oxide, Minimum Percent 20.0 20.6
Alumina Oxide, Maximum Percent 6.0 4.3
Iron Oxide, Maximum Percent 6.0 3.7
Magnesia Oxide, Maximum Percent 6.0 1.2
SO3 (C3A less than 8%), Maximum Percent * 3.2
Loss on Ignition, Maximum Percent 3.0 1.0
Insoluble Residue, Maximum Percent 0.75 0.16
Tricalcium Alumina[e, Maximum Percent 8.0 5
OPTIONAL CHEMICAL REQUIREMENTS .
Total Alkalies, Max. % (NazO equiv.) I 0.60 I 0.46
PHYSICAL'REQUIREMENTS
Specific surface, Blaine Minimum (m2/kg) 280 350
Gillmore, Initial Set, Minimum (Minutes) 60 161
Gillmore, Final Set, Maximum (Minutes) 600 276
Vicar, IMinimum (Minutes) 45
Initial Set lMaximum (Minutes) 375 98
Air Content, Volume, Maximum Percent 12 6
Autoclave Expansion, Maximum Percent 0.80 0.00
Minimum Compressive Strengths MPa psi MPa psi
3 Day 12.0 1740 24.8 3597
7 Day 19.0 2760 31.0 4491
STATE OF TEXAS
Jeff Wendel , being duly sworn deposes and says: that he is Quality Services
Manager of TXI Midlothian Cement Plant, who prepared the above report of tests
Subscribed~nd sworn to before me on this date: August 11, 2000
/
No{aw Public Q~j:C~S ,6p;C',,C'es M a n ag e r
· See ASTM C150 Table 1, Footnote D. ~' --"-"-
¢~ ;?:'....:%-:'. . - .
;~ ~ ~ "r~:~-! ,;o~.-,~¥ ~,,;-?,'T:.~, ~..
~ ",',"--?... ~-~.' :.:..~.,..,,': ~-~.: -::.'c~.~
I '"'.':;..," ,'-, ; .... : '::'~ E~ :: ....
'"'"":--',,2'---:.-~-~. '-"---'-:,:.'r ~", ~-'.:,"
. .. ...~.;~.7.,~ %~, .... '- ........ ,~.
Hanscn A~,qregates
South Central Re~ion
P.O Bcx l§Cg~,g D~_:lss. TX TS~ig
3.500 ;,!a~;e Ave Da:'as, TX 7521~
Te~ 9 i 4-525-5503
v..vw, hA~SCr.~C.COm
DATE: 05/15/2000
~,kATER!AL: Clas~ C Fly Ash SPECIFICATiOi--~: AST~I C-6!8
S~z3[PLED BY: Hanson A~gre~ates TEST PROCEDURE: AST5% C-311
SOURCE: ~750 CASON FLYASH
S.'~-_~4PLE ~-o7.4BER: 8969 i 5 SPECS.
DATE S.~-zv.. P LED: 03/08/2000
PHYSICAL TEST
Specific Gravity 2.72 . . .
Variation. From Avg. (%) .00 5.0 (Max.)
Retained on No. 325 (%) 17.9 34.0 (Max.)
Variation, %Points from Avg. 1.1 5.0 (Max.)
Water Requirement (%) ~3.4 105.0 (Max.)
Pozz Index, % Control !00.3 75.0 (Min.)
Autoclave Soundness (%) .09 +0.8 (Max.)
~,:oisture Content (%) .03 3.0 (Max.)
Loss on Ignition .28 6.0 (Max.)
CHE?,[i CAL TEST
Silicon Dioxide, SIO2(%) 30.79 ...
Aluminum Oxide, A1203(%) 19.65 ...
Iron Oxide, Fe203 (%) 5.54 ...
Total: SiO2;A!2o3;Fe203 % 55.98 50.0 (Min.)
Sulphur Trioxide, SO3(%) 3.84 5.0 (Max.)
Magnesium Oxide, MgO(%) 6.72 . . .
Ca!ciu~. Oxide, CaO(%) 29.16
Sodium Oxide E_~;, Na20(%) 2.10 ...
Available A!kalai as Na20(%) .81
Ken Rave!i
Sales ~.'...anage r
~C/E W.R. Grace & Co. - Conn.
4323 Crites Strut
P.O. Box 2585-77252
Hous:on, 'TX 77003
May 30,2000
TXI
1341 West Mockingbird Lane
Dallas, TX 75247
This is to certify that DARATARD'~ HC, a water-reducing retarding admixture, as
manufactured and supplied by Grace Construction Products, W. R. Grace & Co.-
Conn., is formulated to comply with Specification for Chemical Admixtures for
Concrete, ASTM Designation: C 494, Types B & D (AASHTO M 194, Types B &
D).
DARATARD'~ HO does not contain calcium chloride or chloride containing
compounds as a functional ingredient. Chloride ions may be present in trace
amounts contributed from the domestic water supply used during the
manufacturing process.
The foregoing is in addition to and not in substitution for our standard Conditions
~~.~~d on the reverse side hereof.
Fred Hightower
Technica! Services
Subscribed and sworn to, before me, this _7 ! day of
~1 ,¢-¥ ,2000. ~~~~
My commission expires: /¢~¢,~2
We hope :he i,',~orm,¢'~on ~,'.,e', here ...,qH be help~...,I. I: i$ bcse~ c.", our ~esf
recommendations or s~gges~;ons herein ;n con~uncflon w~th our co~d,dons of ~e -which apply Io ail gc~s s~pp~:~ by us. We o~me no res~nsibili~ for Ihe u~
Grace Construction Products
G~GE W.R. Grace&Co.-Conn.
4323 Crites Street
P.O. Box 2585.77252
Houston, TX 77003
May 3Q,2000
TXI
1341 West Mockingbird Lane
Dallas, TX 75247
Gentlemen: :
This is to ce~ify that ,..,~n~,~,_~v. 65 a mid-range water-reducing admixture, as
manufactured and supplied by Grace Construction Products, W.R. Grace & Co.-
Conn., is formulated to comp!y with Specification for Chemica] Admixtures for
Concrete, ASTM Designation: C 494, Type A (AASHTO M 194, Type A).
DARACEM~ 65 does not contain ca!cium chloride or chloride containing
compounds as a functional ingredient. Chloride ions may be present in trace
amounts contributed from the domestic water supply used during the
manufacturing process.
The foregoing is in addition to and not in substitution for our standard Conditions
of Sale printed on the reverse side hereof.
Fred Hightower
Technical Services
Subscribed and sworn to, before me, this .7/ day &f
.
Nota~ Public/ ~{ ~ OLIVER E. M~'~ ~
We hope Ihe information given here will be helpful. It is based on our bes~ knowledge, end we bel,eve il to be true and accurate. Please read oll stotemenls.
~e¢ommen~o~io~s ~r suggestions ~ere:n in ¢on~uncfi~n wh~ our conditions of ~e w~ch o~ply to ~1 go~s suppl~ by us. We o~ume no ~es~nsi~iJi~
of Ihese s'a~eme~ls. ~ec~mme~dorio~s. or suggestions, nor do ~e intend Ihem as a recommendahon for any use which wouJd in~ring~ any ~lent
G~c. Co. strucfion Prc~t,,ds
4323 Cri~es Street
P.O. ~x 2585-77252
Houston, ~ 77~3
May 30,2000
TXI
1341 West Mockingbird Lane
Dallas, TX 75247
Gentlemen:
This is to certify that DARATARD® 17', a water-reducing & retarding admixture,
as manufactured and supplied by Grace Construction Products, W. R. Grace &
Co.-Conn., is formulated to comply with Specification for Chemical Admixtures
for Concrete, ASTM Designation: C 494, Type D (AASHTO M 194, Type D).
DARATARD® 17 does not contain calcium chloride or chloride containing
compounds as a functional ingredient. Chloride ions may be present in trace
amounts contributed from the domestic water supply used during the
manufacturing process.
The above is in addition to and not in substitution for our standard Conditions of
Sale,orinted on the reverse side hereof.
Fred Hightower
Technical Services
Subscribed and sworn to, before me, this J I day of
My commission expires:
recommendatiOnS cr sugges;:ons I~ere;n in coni~,ncKon wilh our condi;tOnS of sole wh;ch
GRA,C/E W.R. ~:ce & Co. - Conn.
4323 Cdtes Strut
P.O. Box 258~77252
Houston, ~ 77~3
May 30, 2000
TXI
1341 West Mockingbird Lane
Dallas, TX 75247
Gentlemen:
This is to certify WRDA® with HYCO?, a water-reducing admixture, as
manufactured and supplied by Grace Construction Products, W. R. Grace & Co.-
Conn., is formulated to comply with Specification for Chemical Admixtures for
Concrete, ASTM Designation: C 494, Types A & D (AASHTO M 194, Types A &
D).
WRDA® with HYCOLe does not contain calcium chloride or chloride containing
compounds as a functiona~ innrc, r~i~nf Ch!oride ions may be present in trace
amounts contributed from the domestic water supply used dudng the
manu~aoLurlng process.
The foregoing is in addition to and not in substitution for our standard Conditions
of Sale printed on the reverse side hereof.
Fred Hightower
Technica~ Services
Subscribed and sworn to, before me, this _7/ day of
tv,tv commission expires: /~}~¢z . .
We hope the information g:ven here w~l~ be helpful I~ is based on ou~ bes~ ~mow~edge, etd wa be;ieee ~ to be true ~d ¢c:~'3~e. Please cead oll tt~temen~s.
recomme~dct;o~s ¢r suggest;ohs here.n in coniu~cticn wi~h our co~di~io~s of ~e ~hich opply Io cl~, go~s S~pp~;~ by us. We ¢~ume no ~es~nsibili~ fo~ Ihe u~
of ~hese s~eme~s, re:cmmerdarlons, or id~ges'~o~s, ~or do we i~e~ Ihe~n os o recommend=~icn fc~ c-y use wh;ch wou"d [n~ri~¢e gnu ~lant n~ ennu~i~h~
4323 ~ ,S~'~'
May 30,2000 P.O. Ba~ 2.585-772~2 '
Dallas, TX 75247
This is to ccrtify that DARAVAiR· 1000, an air-entraining admixtu~. ,..as manufactured and
supplied by ~ COnstruction Products, W. R. Grace & Co.-Conn.,.is formulated tO .comply
with Specification' for Air-Entraining A 'dm!xtures for Cohcrete, ASTM Desi~ation:
C 260 (AASHTO M 154). :
DARAVAIRe 1000 does not contain calcium chloride or chloride containing compounds as a
functional ingredient..Chloride ions may bel present in trace amounts contributed from the
domestic water supply used during the manufacturing process..
The foregoing is in addition to and not in substitution for our standard Conditions of Sale printed
on the reverse side hereof.
Fred Hightower.
Technical Services
Subscribed and ,worn to, before me. th~!~,'-.~:~ t"-..i:~'!'Jj~¢ day of ~.~./..'.~'-:':' ,2000.
~v'OT/~RYPUBLIC. . .
My commission expires: . .~-.
We ~.~,.~ ~he Infod'mo14on OlvenhdB, ruwlllbehetl~vl. #kba*edo~o~b4~lu,~e~h ondv~b~llloIalrveo~ioccwl~ I~emereedall~aw~,,
TEXAS INDUSTRIES
QUALITY CONTROL DEPT.
AGGREGATE SIEVE ANALYSIS
Date: 07/07/00 Production Facility: TXI- BRIDGEPORT, TEXAS
Size: 5_~7 Grading Designation: ASTM C-33 1" -#4.
Project: ..... ALL TESTS ..... Sample Location:
SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION
SIZE WT. RETAINED % RETAINED % PASSING % RETAINED % PASSING
2.0"
1.5" 0 100 0 100
1.0" 1.72 98.28 0 - 5 95 - 100
%" 17.46 82.54
%" 55.43 44.57 40 - 75 25 - 60
3~8" 79.30 20,70
#4 97.20 2.80 90 - 100 0 - 10
#8 98.83 1.17 95- 100 0- 5
#10
#16
#30
#40
#50
#100
#200 9g.13 0.87
PAN V~'.
Decant .89%
100% of tests: 151 Size: 57 PLANT: BRIDGEPORT Job: ....... ALL JOBS .......
TEXAS INDUSTRIES
QUALITY CONTROL DEPT.
AGGREGATE SIEVE ANALYSIS
Date: 04/28/00 Production Facility: TXI - PARADISE
Designation: C 33 Grading Designation: ASTM C-33 FINE AGG.
Project: .... *ALL TESTS ..... Sample Location:
SIEVE CUMULATIVE CUMULATIVE CUMULATIVE REQUIRED SPECIFICATION
SIZE w'r. RETAINED % RETAINED % PASSING % RETAINED % PASSING
2.0"
1.5"
1.0"
~"
3/8"
~4 .81 99.19 0 - 5 95 - 100
#8 19.02 80.98 0 - 20 80 - 100
#10
#16 35.23 64.77 15 - 50 50 - 85
#30 51.87 48.13 40 - 75 25 - 60
#-40
#50 72.74 27.26 70 - 90 10 - 30
#100 96.05 3.95 90 - 98 2 - 10
#200 98.88 1.12
PAN VVT. 2.76 FINENESS MODULUS
M.C. 5.3%
DECANT
S.E. 91.2%
100% of tests: 93 Size: 33 PLANT: PARADISE Job: ...... *ALL JOBS .......