Town Center L4B1-LR010918 REPORT OF FIELD
COMPACTION TESTS
ALPHA TESTING, INC.
220~ Wisconsin St., Suite 100
Dallas, Texas 75229
972/62~8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR CONSTRUCTION MANAGEMENT GROUP DATE 09/18/01
DALLAS, TEXAS
PROJECT COPPELL TOWN CENTER OUR REPORT NO. 01612-16
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
24 09/18/01 FG 1 15.5 101 15.6 98 97 1 -A
25 09/18/01 FG 1 15.5 101 17.5 102 101 1-A
26 09/18/01 FG 1 15.5 101 18.0 99 98 1-A
27 09/18/01 FG 1 15.5 101 18.1 101 100 1-A
28 09/18/01 FG 1 15.5 101 17.6 100 99 1-A
TEST LOCATION:
24 WEST PARKING AREA, 15' NORTH AND 20' EAST FROM SOUTHWEST CORNER
25 WEST PARKING AREA, 24' NORTH AND 20' WEST FROM SOUTHEAST CORNER
26 WEST PARKING AREA, 65' NORTH AND 45' WEST FROM SOUTHEAST CORNER
27 WEST PARKING AREA, 25' EAST AND 25' SOUTH FROM NORTHWEST CORNER
28 WEST PARKING AREA, 35' WEST AND 20' SOUTH FROM NORTHEAST CORNER
3. LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
Our test results & reports are for the excl~lslye use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or dis exp,'ess appraisal ALPHA. The use
of out'name&test results must receive our written approval Test results & repo.s apply only to the samples tested and/or ob .... d, and ffibuted ex, iR:~
are not intJlcatlve of the ( )f apparently idi~htical o~' similar specimens.
Geotechnical Engineenng · Construction Materials Teshng · Environmental Engineering · Consulting