Wynnpage Plaza-CS011008 BENTLEY ENGINEERING, iNC.
CIVIL ENGINEERING · PLAlX~'ING
CONSTRLTCTION MANAGEMENT
MARC O. BENTEEY, P.E.
October 8, 2001 ~ 2-0 ~ - ~ i A 1 ?: 3 9 P, C ',.' C.
Mr. Kenneth M. Griffin, P.E.
Director of Engineering & Public Works
City of Coppell
255 Parkway
Coppell, Texas 75019
Re: Wynnpage Plaza
Dear Mr. Griffin:
Attached are two (2) sets of the site development plans for the referenced project. We
are submitting these plans for your review and comments.
.We are requesting that the on-site pavement be 6 inch thick 4000 PSI reinforced
concrete pavement with #3 rebar on 18 inch centers in both directions on 6 inch com-
pacted subgrade. This request is being made in lieu of lime stabilizing the subgrade.
We would appreciate your consideration of our alternate paving section. If you should
have any questions or concerns, please do not hesitate to call.
Sincerely,
BENTLEY ENGINEERING, INC.
Marc O. Bentley, P.E.
Attachment
?02 GATEWOOD DRIVE GARLAND, TEXAS 75043 (972)_40-4__1 FAX (972) 240-0922