Hackberry Addition-LR180918 REPORT OF PIER OBSERVATION Springhill Suites 150 Hackberry Road Coppell, Texas REPORTED TO: Northpoint Construction, LLC REPORT NO. 8 8530 Esters Boulevard REPORT DATE: 09-18-18 Irving, Texas 75063 REG PROJECT NO. 22574 ATTN: Mr. Dilip Pranav TECHNICIAN: K. Wicks PAGE: 1 of 2 CONTRACTOR: Northpoint Construction, LLC Pier Diameter Bell Diameter Depth Before Final Depth Concrete DatePier No. (inches)(inches)Bell (feet) of Pier (feet) Length (feet) 08-29-18 L.1/1 18 54 18.3 18.3 15.3 K.5/1 1854 18.6 18.8 16.3 I.7/1 1842 18.5 18.7 15.7 H.1/1 1866 18.4 18.6 15.6 F.9/1 1854 18.0 19.1 16.6 E/1 1854 18.2 19.0 16.5 I/2 1854 18.7 19.4 16.4 I.5/2 1854 18.8 19.1 16.6 K/2 1854 18.0 18.9 15.9 K.6/2 1854 18.2 18.7 15.7 M/2 1854 19.0 19.2 16.2 K.4/3 1854 19.2 19.8 16.8 M.9/5.6 1854 19.1 19.3 16.3 M/5.8 1845 19.1 19.4 16.9 M.9/6.3 1854 18.7 19.0 16.0 M.4/8.1 1845 18.6 19.3 16.3 H.9/4.4 1854 18.4 19.0 16.5 H/5 1842 18.7 19.6 17.1 08-30-18 H.4/4.1 1854 1835 19.0 16.5 H.4/5 1842 18.0 18.5 16.0 K.3/4 1845 18.0 18.8 16.0 L/3.3 1842 20.0 20.2 17.2 H/6 1842 18.7 19.4 16.9 I/6 1854 18.7 19.0 16.5 I.3/5.3 1854 18.8 19.0 16.5 I.6/5.3 1854 18.7 18.7 16.2 I.6/6 1854 18.6 19.3 16.8 J/6 1854 18.8 18.9 16.4 K/6 1854 18.9 19.3 16.3 I.4/5 24 60 18.7 19.3 16.3 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL \[214\] 350 5600 FAX \[214\] 350 0019 REPORT NO. 8 REPORT DATE: 09-18-18 REG PROJECT NO. 22574 TECHNICIAN: K. Wicks PAGE: 2 of 2 Pier Diameter Bell DiameterDepth Before Final Depth Concrete DatePier No. (inches)(inches)Bell (feet) of Pier (feet) Length (feet) 08-30-18 I/3 2472 18.8 19.4 16.4 J.2/3 2472 19.0 19.6 16.6 L/4 2466 18.9 19.8 16.8 M/5 2472 18.7 19.3 16.8 N/5 2460 18.6 19.6 16.6 M/3 2460 19.0 19.2 16.2 I/1 2466 18.7 19.1 16.6 J/4 18 45 18.8 19.1 16.6 08-31-18 J.9/1 24 54 18.8 19.8 17.3 I.6/3 24 72 18.3 19.0 16.0 J/5 24 72 18.7 19.6 16.6 K.7/4 18 45 19.0 19.2 16.6 M.3/7.3 1842 19.4 20.2 17.2 M.3/9 1854 19.0 20.2 17.2 I.9/8.9 1845 19.3 20.0 17.0 H/8.9 1845 19.3 20.1 17.1 I.5/8.9 1854 20.0 20.7 17.7 H.4/9.6 1842 20.0 20.5 17.5 E.9/8.5 1836 20.1 20.1 17.1 G/8.1 1842 19.8 20.3 17.3 G/8.9 1842 20.0 20.0 17.0 F/9.3 1836 19.8 20.2 17.2 G/9.8 1836 20.0 20.4 17.4 E/8 1836 20.1 20.2 17.2 C.5/8 1836 20.0 20.2 17.2 Reinforcing Steel: 18” 4-6 #5 bars with #3 ties at 12 inches O.C. 24” 4-6 #5 bars with #3 ties at 12 inches O.C. Submitted by: E-Mail Distribution:(1) Northpoint Construction, LLC/ REED ENGINEERING GROUP, LTD. Mr. Dilip Pranav (1) Northpoint Construction, LLC/ Registration Number F-3114 Mr. Jaime Ogden Bill Woolwine Sr. Manager, CMT BW/jm