Loading...
Petterson (Encore)-LR181105 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 RECH COPPELL, LLC11/05/2018 Tested For:Date Issued: ATTN:MATT MILDREN 173166-468490-S1 Our Report #: 4145 TRAVIS STREET, SUITE 202 DALLAS, TX 75204 TODD SMITH PM: Fax Number: PETTERSON ADDITION - ENCORE OF COPPELL Project Desc: NW CORNER OF SUMMER PLACE DR AND SANDY LAKE ROAD FIELD DATA PAVING PATCH: ALLEY OF SUMMER PLACE DR. Placement Location: ALLEY OF SUMMER PLACE DR. Sample Location: 10/25/2018RELIABLE Date Placed:Concrete Supplier: 10:10 AM01 Time Placed:Plant Number: 092722 ALPHADelivery Ticket No.: Cast By: 9:11:00 AM Batch Time: Result 40600A Mix ID: 70 Concrete Temp (F): Parvataneni, Srinath Submitted By: 6.0 Slump (ASTM C-143): 10/26/2018 Date Received: 3.0 (ASTM C-173) Air Content: ASTM C-31 Cured Specification: 60 Ambient Temp (F): 4000 Specified Strength: N/A Unit Weight: CYLINDER COMPRESSION TEST RESULTS LabCureBreakCapDateAgeAvg.Avg.Avg Depth/Area:Max PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 5311/1/2018712.56322402570 LAB2C-12318N/A4 54LABC-123111/22/2018288N/A412.560 55LABC-123111/22/2018288N/A412.560 56LABC-123111/22/2018288N/A412.560 PMB Capital Investments, Clay Moore Engineering, City of Coppell, City of Coppell CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting338645