Petterson (Encore)-LR181127
Alpha Testing, Inc.
2209 Wisconsin St.
Concrete Compression Test
Dallas, TX 75229
(972)620-8911
Report
TBPE Firm No. 813
RECH COPPELL, LLC11/27/2018
Tested For:Date Issued:
ATTN:MATT MILDREN
173166-468490-S1
Our Report #:
4145 TRAVIS STREET, SUITE 202
DALLAS, TX 75204
TODD SMITH
PM:
Fax Number:
PETTERSON ADDITION - ENCORE OF COPPELL
Project Desc:
NW CORNER OF SUMMER PLACE DR AND SANDY LAKE ROAD
FIELD DATA
PAVING PATCH: ALLEY OF SUMMER PLACE DR.
Placement Location:
ALLEY OF SUMMER PLACE DR.
Sample Location:
10/25/2018RELIABLE
Date Placed:Concrete Supplier:
10:10 AM01
Time Placed:Plant Number:
092722
ALPHADelivery Ticket No.:
Cast By:
9:11:00 AM
Batch Time:
Result
40600A
Mix ID:
70
Concrete Temp (F):
Parvataneni, Srinath
Submitted By:
6.0
Slump (ASTM C-143):
10/26/2018
Date Received:
3.0
(ASTM C-173)
Air Content:
ASTM C-31
Cured Specification:
60
Ambient Temp (F):
4000
Specified Strength:
N/A
Unit Weight:
CYLINDER COMPRESSION TEST RESULTS
LabCureBreakCapDateAgeAvg.Avg.Avg Depth/Area:Max
PSI:
No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load:
5311/1/2018712.56322402570
LAB2C-12318N/A4
54LAB2C-123111/22/2018288N/A412.56505664030
55LAB3C-123111/22/2018288N/A412.56508154050
56LAB2C-123111/22/2018288N/A412.56501994000
Average 28-day Compressive Strength is compliant with project specifications
4030
PMB Capital Investments, Clay Moore Engineering, City of Coppell, City of Coppell
CC:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc.
Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM
C39.
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting338645