FEMA-EC100406Page 1 of 3 Date: January 28, 2010 Case "1.: 10-06-0950A LOMB-FW
Federal Emergency Management Agency
Washington, D.C. 20472
D tib
LETTER OF MAP REVISION FLOODWAY
DETERMINATION DOCUMENT (REMOVAL)
COMMUNITY AND MAP PANEL INFORMATION LEGAL PROPERTY DESCRIPTION
CITY OF COPPELL,DALLAS Lot 2, Block 1, Bethel Road Estates, as shown on the Plat, recorded
COUNTY,TEXAS as Instrument No. 1058807, Volume 2000134, Pages 02875 through
02878, in the Office of the County Clerk, Dallas County, TexasCOMMUNITY
The portion of property is m-:7re particularly described by the following
COMMUNITY NOV.480170 metes and bounds:
AFFECTED
NUMBER:48113C0155,1
MAP PANEL
DATE: 8/23/2001
FLOODING SOURCE: TRIBUTARY G-1 OF GRAPEVINE APPROXIMATE LATITUDE&LONGITUDE OF PROPERTY:32.955, -97.000
CREEK SOURCE OF LAT&LONG:ESRI:FEMA GEOCODE/GOOGLE MAPS DATUM:NA f)83
DETERMINATION
IOUTCOME 1%ANNUAL LOWEST LOWEST
BLOCK/ WHAT IS CHANCE ADJACENT LOT
LOT SUBDIVISION STREET REMOVED FROM FLOOD FLOOD GRADE ELEVATIONSECTION
THE SFHA ZONE ELEVATION ELEVATION (NGVC,29)
NGVD 29) (NGVD 29
2 1 Bethel Road 256 Bethel Road Portion of X 493.9 feet 498.0 feet
Estates Property (unshaded)
Special Flood Hazard Area (SFHA) - The SFHA is an area that would be inundated by the flood having a 1-percent chance of being
equaled or exceeded in any given year(base flood).
ADDITIONAL CONSIDERATIONS(Please refer to the appropriate section on Attachment 1 fnr the additional considerations listed below.)
LEGAL PROPERTY DESCRIPTION REVISED BY LETTER OF MAP REVISION
INADVERTENT INCLUSION FLOODWAY 1 STUDY UNDERWAY
PORTIONS REMAIN IN THE SFHA
This document provides the Federal Emergency Management Agency's determination regarding a renuest for a Letter of Map Revision for the
property described above. Using the information submitted and the effective National Flood Insurance Program (NFIP) map, we have
determined that the described portionts) of the property(ies) is/are not located in the 01FIP regulatory floodway or the SFHA, an area inun sated
by the flood having a 1-percent chance of being equaled or exceeded in any given year (base flood). This document revises the effective NFIP
map to remove the subject property from the NFIP regulatory floodway and the SFHA located on the effective NFIP map; therefore, the Federal
mandatory flood insurance requirement does not apply. However, the lender has the option to continue the flood insurance requirement to
protect its financial risk on the loan. A Preferred Risk Policy (PRP) is available for buildings located outside the SFHA. Information about the
PRP and how one can apply is enclosed.
This determination is based on the flood data presently available. The enclosed documents provide additional information regarding this
determination. If you have any questions about this document, please contact the FEMA Map Assistance Center toll free at (877) 336-2627
877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency, LOMC Clearinghouse, 6730 Santa Barbara Court,
Elkridge, MD 21075.
Kevin C.Long,Acting Chief
Engineering Management Branch
Mitigation Directorate
Page 2 of 3 Date: January 28, 2010 ICas '"w
1.: 10-06-0950A LOMR-FW
u/ Federal Emergency Management Agencys'
Washington, D.C. 204724NI)s'
LETTER OF MAP REVISION FLOODWAY
DETERMINATION DOCUMENT (REMOVAL)
ATTACHMENT 1 (ADDITIONAL CONSIDERATIONS)
LEGAL PROPERTY DESCRIPTION (CONTINUED)
COMMENCING from the Northwest corner of Lot 2, thence S01°01'30"W, a distance of 63.12 feet to the POINT
of BEGINNING; Thence N70°09'35"E, a distance of 67.83 feet; Thence S89°38'17"E, a distance of 54.73 feet;
Thence S06°38'40°E, a distance of 40.01 feet; Thence 506'17'31"W, a distance of 56.51 feet; Thence
S11°32'11"W, a distance of 56.14 feet; Thence S09°15'00"E, a distance of 37.43 feet; Thence S12°59'00"E, a
distance of 78.56 feet; Thence S13°58'19"E, a distance of 53.30 feet, being a point in the Southline of Lot
2;Thence N24°41'27"W, a distance of 32.94 feet; Thence N18°31'40"W, a distance of 34.90 feet; Thence
N20°55'38"W, a distance of 162.17 feet; Thence N50°58'45"W, a distance of 40.74 feet; Thence S81°41'19"W,
a distance of 29.19 feet; Thence N01°01'20"E, a distance of 57.54 feet to the POINT OF BEGINNING
INADVERTENT INCLUSION IN THE FLOODWAY 1 (PORTIONS OF THE PROPERTY REMAIN IN THE
FLOODWAY) (This Additional Consideration applies to the preceding 1 Property.)
A portion of this property is located within the National Flood Insurance Program (NFIP) regulatory floodway for
the flooding source indicated on the Determination Document, while the subject of this determination is not. The
NFIP regulatory floodway is the area that must remain unobstructed in order to prevent unacceptable increases in
base flood elevations. Therefore, no construction may take place in an NFIP regulatory floodway that may cause
an increase in the base flood elevation, and any future construction or substantial improvement on the property
remains subject to Federal, State/Commonwealth, and local regulations for floodplain management. The NFIP
regulatory floodway is provided to the community as a tool to regulate floodplain development. Therefore, the
NFIP regulatory floodway modification described in the Determination Document, while acceptable to the Federal
Emergency Management Agency (FEMA), must also be acceptable to the community and adopted by
appropriate community action, as specified in Paragraph 60.3(d) of the NFIP regulations. Any proposed revision
to the NFIP regulatory floodway must be submitted to FEMA by community officials. The community should
contact either the Regional Director (for those communities in Regions I-IV, and VI-X), or the Regional Engineer
for those communities in Region V) for guidance on the data which must be submitted for a revision to the NFIP
regulatory floodway. Contact information for each regional office can be obtained by calling the FEMA Map
Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or from our web site at
http://www.fema.goviaboutiregoff.htm.
PORTIONS OF THE PROPERTY REMAIN IN THE SFHA (This Additional Consideration applies to the
preceding 1 Property.)
Portions of this property, but not the subject of the Determination/Comment document, may remain in the Special
Flood Hazard Area. Therefore, any future construction or substantial improvement on the property remains
subject to Federal, StateiCommonwealth, and local regulations for floodplain management.
This attachment provides additional information regarding this request. If you have any questions about this attachment, please contact the
FEMA Map Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or by letter addressed to the Federal Emergency Management
Agency, LOMC Clearinghouse,6730 Santa Barbara Court, Elkridge,MD 21075.
Kevin C.Long,Acting Chief
Engineering Management Branch
Mitigation Directorate
Page-3 of 3 Date: January 28, 2010 Cas 1.: 10-06-0950A LOMR-FW
Federal Emergency Management Agency
r^L Washington, D.C.20472
LETTER OF MAP REVISION FLOODWAY
DETERMINATION DOCUMENT (REMOVAL)
ATTACHMENT 1 (ADDITIONAL CONSIDERATIONS)
REVISED BY LETTER OF MAP REVISION (This Additional Consideration applies to the
preceding 1 Property.)
The effective National Flood Insurance Program map for the subject property, has since been revised by a Letter
of Map Revision (LOMR) dated 4!24/2008. The 4/24/2008 LOMR has been used in making the
determination/comment for the subject property.
STUDY UNDERWAY (This Additional Consideration applies to all properties in the LOMR-FW
DETERMINATION DOCUMENT (REMOVAL))
This determination is based on the flood data presently available. However, the Federal Emergency
Management Agency is currently revising the National Flood Insurance Program (NFIP) map for the community.
New flood data could be generated that may affect this property. When the new NFIP map is issued it will
supersede this determination. The Federal requirement for the purchase of flood insurance will then be based on
the newly revised NFIP map.
This attachment provides additional information regarding this request. If you have any questions about this attachment, please contat the
FEMA Map Assistance Center toll free at (877) 336-2627(877-FEMA MAP) or by letter addressed to the Federal Emergency Management
Agency, LOMC Clearinghouse,6730 Santa Barbara Court,Elkridge,MD 21075.
r
Kevin C. Long,Acting Chief
Engineering Management Branch
Mitigation Directorate
S'C1L2A.NII SYSTEMS 6221 Riverside Dr#116/ Irving,TX 75039
Phone 972-620-8204/www.strandsystems.comENGINEERINGINCFAXRes: 972-488-8932/FAX Apts: 972-243-5417
March 12, 2010 S2E#0908480
The Holmes Builders of Coppell, LTD
1445 MacArthur, Suite 200
Carrollton, TX 75007
RE: Private Residence 256
256 West Bethel Road
Coppell, TX
Lot: 2 Block:
Pre-Pour Inspection
Gentlemen:
This letter is to affirm that a representative of this firm performed a Pre-Pour
inspection of the foundation at the above noted address on 3/11/2010. An inspection
checklist was left at the job site.
Based on this inspection, the beam excavations and steel placement were found to
be in substantive compliance with the plans, specifications, and acceptable industry
standards and practices.
We trust that this is the information you require. Please contact this office if we may
be of additional assistance.
Respectfully,
Strand Systems Engineering, Inc.
o F tTtill
i:01r< 1J11
TAMARA L. SPICER
Tami L Spicer, P.E. 92474
President 1r0 o;. r
t 111ONALE^.ltttit
Registration No: F-1629
o,„,w.,o,,,„,-,. .a ,,,mvw„.,,„,.,,...w.xr-„mnwnuie.rn.r.,,rmm.,.,.,
kl
tP1;?:tr3.MECT. e
CrT`Y` E TIC
r
Y'LOT SdTE • k'
FEE:
1
2.Fail:
c
Lam. 1E
t• +. .4'i! i” : "
fi
M,
y tP 44
hr 1
k
f
a
a r v
r
RB
2.Stza: f . 3. s '
t4. vt a `f
S_ 7 +
1
fl
iI
f
5' [ND `'YSTEMS
6971 Riverside Dr
ww.s/
Irving,
to
75039
Phone 972-620-8204/wwvv.strandsystems.com
N GAN F L 1 J N G 1N C FAX Res:972-488-89321 FAX Apts:972-243-5417
February 22, 2010 S2E#0908480
The Holmes Builders of Coppell, LTD
1445 MacArthur, Suite 200
Carrollton, TX 75007
RE: Private Residence 256
256 West Bethel Road
Coppell, TX
Lot: 2 Block:
Pier Inspection
Gentlemen:
This letter is to affirm that a representative of this firm performed a Pre-Pour/Pour
pier inspection of the referenced project foundation on 2/19/2010
During the inspection it was observed that the piers and reinforcing were installed
per plans and specifications. An inspection checklist was left at the job site.
No. of Piers - 9/79
Pier Diameter - 12"
Pier Depth - 25'
Piers were located as shown on approved plans.
No water encountered, and all piers drilled to full design depth or greater. All piers
were founded on acceptable soil.
Respectfully,
Strand Systems Engineering, Inc. 1
err
4 /1.4e"----
TAMARA L. SPICER Ps
Tam i L Spicer, P.E. rei-o'. 92474 :c_r
President
k ,s;.
NALlE\
Registration No F-1629
Enc: design calculations
S'TIZ.ANr) SYSTEMS
6971 Riverside
0-82 / ww.s/
Irving,
to
75039
Phone 972-620-8204/w+rnrv.strandsystems.com
EN GAIN I L LLNG iN G FAX Res:972-488-89321 FAX Apts:972-243-5417
April 09, 2010 82E#0908480
The Holmes Builders of Coppell, LTD
1445 MacArthur, Suite 200
Carrollton, TX 75007
RE: Private Residence 256
256 West Bethel Road
Coppell, TX
Lot: 2 Block:
Pier Inspection
Gentlemen:
This letter is to affirm that a representative of this firm performed a Pre-Pour/Pour
pier inspection of the referenced project foundation on 4/7/2010
During the inspection it was observed that the piers and reinforcing were installed
per plans and specifications. An inspection checklist was left at the job site.
No. of Piers - 11/80
Pier Diameter - 12"
Pier Depth - 25'
Piers were located as shown on approved plans.
No water encountered, and all piers drilled to full design depth or greater. All piers
were founded on acceptable soil.
Respectfully,
Strand Systems Engineering, Inc.0 F •rF-ktt
dr:
vt P'
TAMARA L. SPICER
Tamara L Spicer, P.E. rj-o-. 92474 . r
President a;
r
Registration No
Enc: design calculations
F-1629
FR.A.ND SYSTElVvS
6971 Riverside
0-82 I #
1161 Irving,
to
75039
Phone 972-620-8204/www.strandsystems.com
GAIN EE1 .11M G 1N C FAX Res:972-488-89321 FAX Apts:972-243-5417
April 12, 2010 S2E#0908480
The Holmes Builders of Coppell, LTD
1445 MacArthur, Suite 200
Carrollton, TX 75007
RE: Private Residence 256
256 West Bethel Road
Coppell, TX
Lot: 2 Block:
Pier Inspection
Gentlemen:
This letter is to affirm that a representative of this firm performed a Pre-Pour/Pour
pier inspection of the referenced project foundation on 4/8/2010
During the inspection it was observed that the piers and reinforcing were installed
per plans and specifications. An inspection checklist was left at the job site.
No. of Piers - 12/80
Pier Diameter - 12"
Pier Depth - 25'
Piers were located as shown on approved plans.
No water encountered, and all piers drilled to full design depth or greater. All piers
were founded on acceptable soil.
Respectfully,
Strand Systems Engineering, Inc.
c-D •• _...k. •rr
1{ 7/1."---
P
Ps *TAMARA L. SPICER* es
Tamara L Spicer, P.E. 0', 92474 :ck.
President 6]o•
0.•'.(C NSEO..' .r••
Registration No
Enc: design calculations
F-1629
s ND SYSTEMS
6971 Riverside
0-82
Dr#1161 Irving,
to
75039
Phone 972-620-8204/v nrwv.strandsystems.com
J JN GIN F L 1Z1N G 1N C FAX Res:972-488-89321 FAX Apts:972-243-5417
April 12, 2010 S2E#0908480
The Holmes Builders of Coppell, LTD
1445 MacArthur, Suite 200
Carrollton, TX 75007
RE: Private Residence 256
256 West Bethel Road
Coppell, TX
Lot: 2 Block:
Pier Inspection
Gentlemen:
This letter is to affirm that a representative of this firm performed a Pre-Pour/Pour
pier inspection of the referenced project foundation on 4/9/2010
During the inspection it was observed that the piers and reinforcing were installed
per plans and specifications. An inspection checklist was left at the job site.
No. of Piers - 14/80
Pier Diameter - 12"
Pier Depth - 25'
Piers were located as shown on approved plans.
No water encountered, and all piers drilled to full design depth or greater. All piers
were founded on acceptable soil.
Respectfully,
Strand Systems Engineering, Inc.ar 7e(11
1---.in-4(4 7/11.••••-••err
e' TAMARA L. SPICER
Tamara L Spicer, P.E. 92474
President 6(a.;
Registration No.F-1629Enc: design calculations
U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008
Federal Emergency Management Agency
Expires March 31, 2012
National Flood Insurance Program Important: Read the instructions on pages 1-9.
SECTION A- PROPERTY INFORMATION For Insurance Company Use
Al. Building Owner's Name TERRY HOLMES Policy Number
A2. Building Street Address(including Apt., Unit,Suite,and/or Bldg. No.)or P.O. Route and Box No. Company NAIC Number
256 BETHEL ROAD
City COPPELL State TX ZIP Code 75019
A3. Property Description(Lot and Block Numbers,Tax Parcel Number, Legal Description,etc.)
Lot 2,of BETHEL ROAD ESTATES, COPPELL, DALLAS COUNTY,TEXAS
A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory,etc.)RESIDENTIAL
A5. Latitude/Longitude: Lat. Long. Horizontal Datum: ® NAD 1927 NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number NA
A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage:
a) Square footage of crawlspace or enclosure(s) N/A sq ft a) Square footage of attached garage N/A sq ft
b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage
enclosure(s)within 1.0 foot above adjacent grade N/A within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.b N/A sq in c) Total net area of flood openings in A9.b N/A sq in
d) Engineered flood openings? Yes ® No d) Engineered flood openings'? Yes ® No
SECTION B-FLOOD INSURANCE RATE MAP(FIRM) INFORMATION
B1. NFIP Community Name&Community Number B2. County Name B3. State
DALLAS COUNTY&INCORPORATED AREAS 48113C DALLAS TEXAS
B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s)(Zone
48113C 0155 J Date Effective/Revised Date Zone(s) AO, use base flood depth)
06-16-2005 08-23-2001 AE&X 494.0'
B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item B9.
FIS Profile ® FIRM Community Determined Other(Describe)
B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 NAVD 1988 Other(Describe)
B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? Yes ® No
Designation Date CBRS OPA
SECTION C -BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: Construction Drawings* Building Under Construction*Finished Construction
A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations-Zones A1-A30,AE,AH,A(with BFE),VE,V1-V30,V(with BFE),AR,AR/A,AR/AE,AR/A1-A30,AR/AH,AR/AO. Complete Items C2.a-h
below according to the building diagram specified in Item A7. Use the same datum as the BFE.
Benchmark Utilized ELEV 513.24Vertical Datum NGVD 1929
Conversion/Comments BM PROVIDED BY COPPELL GPS MONUMENT
Check the measurement used.
a) Top of bottom floor(including basement, crawlspace, or enclosure floor)499.97 ®feet meters(Puerto Rico only)
b) Top of the next higher floor N/A.LI feet [' meters(Puerto Rico only)
c) Bottom of the lowest horizontal structural member(V Zones only)N/A.feet meters(Puerto Rico only)
d) Attached garage(top of slab) N/A.feet meters(Puerto Rico only)
e) Lowest elevation of machinery or equipment servicing the building N/A.feet meters(Puerto Rico only)
Describe type of equipment and location in Comments)
f) Lowest adjacent(finished)grade next to building(LAG) 498.87 ®feet meters(Puerto Rico only)
g) Highest adjacent(finished)grade next to building(HAG) 498.99 ®feet meters(Puerto Rico only)
h) Lowest adjacent grade at lowest elevation of deck or stairs, including N/A.feet meters(Puerto Rico only)
structural support
SECTION D -SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor,engineer, or architect authorized by law to certify elevation
information. /certify that the information on this Certificate represents my best efforts to interpret the data available.
1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. o F lF •
Check here if comments are provided on back of form. Were latitude and longitude i n Section A provided by a co •'O
s;9•••4p
licensed land surveyor? ® Yes No
Certifier's Name BARRY RHODES License Number 3691 1 BARRY S.RHODES
Title OWNER, RPLS Company Name RHODES SURVEYING
t"'.
1.
3691
0' i'
Address 7509 PENNRIDGE IRCLE City ROWLETT State TX ZIP Code 75088 q .............
t ,
pQ
Signature Date 4-6-2010 Telephone 972-475-8940
FEMA Form 81-31, Mar 09 See reverse side for continuation. Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use:
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number
256 BETHEL ROAD
City COPPELLState TX ZIP Code 75019 Company NAIC Number
SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for(1)community official, (2)insurance agent/company,and(3)building owner.
Comments HOUSE IS UNDER CONSTRUCTION
Signature Date 4-6-2010
Check here if attachments
SECTION E- BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A(WITHOUT BFE)
For Zones AO and A(without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request,complete Sections A, B,
and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only,enter meters.
El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade(HAG)and the lowest adjacent grade(LAG).
a)Top of bottom floor(including basement,crawlspace,or enclosure)is N/A. feet meters above or below the HAG.
b)Top of bottom floor(including basement,crawlspace, or enclosure)is N/A. feet meters above or below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9(see pages 8-9 of Instructions),the next higher floor
elevation C2.b in the diagrams)of the building is N/A. feet meters above or below the HAG.
E3. Attached garage(top of slab)is N/A. feet meters above or below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is 0.0 LI feet meters ®above or below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? Yes No Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER(OR OWNER'S REPRESENTATIVE)CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A(without a FEMA-issued or community-issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
Check here if attachments
SECTION G -COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C(or E),
and G of this Elevation Certificate. Complete the applicable item(s)and sign below. Check the measurement used in Items G8 and G9.
G1. LI The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,engineer, or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. A community official completed Section E for a building located in Zone A(without a FEMA-issued or community-issued BFE)or Zone AO.
G3. The following information(Items G4-G9)is provided for community floodplain management purposes.
G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued
G7. This permit has been issued for: LI New Construction Substantial Improvement
G8. Elevation of as-built lowest floor(including basement)of the building:feet meters(PR) Datum
G9. BFE or(in Zone AO)depth of flooding at the building site: feet meters(PR)Datum
G10. Community's design flood elevation feet meters(PR)Datum
Local Official's Name Title
Community Name Telephone
Signature Date
Comments
Check here if attachments
FEMA Form 81-31, Mar 09 Replaces all previous editions
Building Photographs
See Instructions for Item A6.
For Insurance Company Use:
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number
256 BETHEL ROAD
City COPPELL State TX ZIP Code 75019 Company NAIC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, Right
Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page on the
reverse.
FRONT VIEW
a .4.
i..t!G.•-:-},.;,..._._ ....1!
7LII.
1 .1 I . L
tl i `.
I a
t
y
4
r' >,
p....
i '
Building Photographs
Continuation Page
For Insurance Company Use:
Building Street Address(including Apt., Unit, Suite, and/or Bldg. No.)or P.O. Route and Box No. Policy Number
256 BETHEL ROAD
City COPPELL State TX ZIP Code 75019 CompanyNAlCNumber
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all
photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View."
REAR VIEW
Y
r
f.
pf
e
r' • , a
4.: _ .4r
i .:
A.
i
1
sac
a t r
as p
t
aXF*
to
A
w
w
1 ' '1,41sNik,"*".1to"
4,.„,,,,r,....,...,::: „,. ..,, ,...,,,, ..,ti.. . — ,,,!- ..,:-..;,,..: .-,,,,.. ,,.,,-,-.‘ .:... .-...---;
a4,- -- . , ,,,"----‘0...a.
441.
1
17 µr-"
1
k , .
fit+ "
y ,
y *.. f,
1„. .;.
t°
y4
sy+,
M `
1
Witte:
w'-: yy, k,A •Y
v" '
4
t.-. 1
yam
SURVEY PLAT
TEXT
IMPROVEMENT
BOUNDARY L I'
EASEMENT/-WarAIWN4111
NM RESIDENCE/FENCES
v44 7i
BIG CEDAR ADDITION
VOLUME PAGE
92125 3455
4 3
2
5
N. N 88°55'03" E 241 .81 '
o
y
Pc,\ .•oint in Creek Point in Creek
6 ` •Point in Creek
In
CC
Lai 100 YEAR FLOOD
94' CONTOUR
5 PER FEMA MAPS)
D7
in
w
0 I
I ao
of
1/2 REF. -
I
m
MONU. FND I
2.7'
1,{,2 REF. + I NwMOtfIJ. FND v}O 3' I 2.348 AC. cNj aI
cn co I I'-- 0
O
Ii-Ij I w 4G -^)
Y
v)
I k
p UJ ce Q`4,
I .. I z 45, JcpO
r 1 o I •.75.8
I tV
go '
J3`y'b
Z w o I Ni .
f- I o 48.1 18.9 I- z
FORMS ONLY
I I-
Cr Nx I
aa-
I OLi
0 I 288) I O o
3r1:
T.O.F.= 499.97' I U)
002'0 -24-5'1$3' —18.0' 9r5V \0 O 4
Z 13.2.0' 9.9'
2 \
Z
157.6'
w ti 19.3' 47
o
a• I D, \
N
O 157.9'
24.6' \
UTILITY EASEMENTFLo.
I E).P.
I v \
I 83.6' N
I 21.3'- 10.1
x I
00r FORMS 1ONLY1. ' 141.1'
N STONE WALL
N T.Q.F.= 499.98',
OLUMN p o 1. \ 30' BUILDING LINE
fie _
3.5- .( 0.4M 23.2`
4 ` _
sq. Cut= 49s s' S\ 00°17'22" E
STONE/WALL n 15.00'
1/2 IRF
41/
2 IRF
P/K MD)
fl.9' /
ii II J o \ 1/2 IRF
S 8
82.33'
W
City of Dallas
S : °422'38" W 1 gl.4q'OVER-HEAD POWER
82.33'
VOLUME PAGE
Z Z Z Z Z ti Z Z Z—Z— —Z\----Z Z---Z Z Z—Z ZZ---- 439 27
THIS CERTIFICATION DOES NOT ASPHALT %' P.P. I
TAKE INTO CONSIDERATION
BETHEL ROADADDITIONALFACTSTHATAN ASP+{At7
ACCURATE TITLE SEARCH AND OR
EXAMINATION MIGHT DISCLOSE.
BARRY S. RHODES Registered Professional Land Surveyor (972) 475-8940
This is to certify that I have, this dote, made a careful and accurate survey on the ground of property
located at No. 256 BETHEL ROAD in the city of COPPELL Texas.
Lot No. 2 Block No.
of BETHEL ROAD ESTATES an addition to the City of
COPPELL, DALLAS COUNTY Texas according to the PLAT RECORDED
in FILE PENDING at FILE PENDING of the MAP records of DALLAS COUNTY, TEXAS.
The plot hereon is true, correct, and accurate representation of the property as determined by
survey, the lines and dimensions of said property being as indicated by the plot:the size, location cfG 9F T: .
and type of building and improvements are as shown, all improvements being within the boundaries c'
Cl?•
01 g T •4 '.
of the property, set bock from property lines the distance indicated.
THERE ARE NO ENCROACHMENTS, CONFLICTS, OR PROTRUSIONS,EXCEPT AS SHOWN.
ARRY S.R e e
r
THIS SURVEY WAS PERFORMED EXCLUSIVELY FOR 3691Scale:1 " = 50'
HOLMES BUILDERS 90
Date: 4-6-2010
USE OF THIS SURVEY FOR ANY OTHER PURPOSE yp aj
G. F. No.: OR OTHER PARTIES SHALL BE AT THEIR RISK AND r.`
Job no.: 75581 UNDERSIGNED IS NOT RESPONSIBLE TO OTHERS
Drown by: JD FOR ANY LOSS RESULTING THEREFROM.