Loading...
FEMA-EC9703257They With A Beautiful Future BUILDING PERMIT APPLICATION /-7 77. 2 C% Print or Twe in a Clear, Leaible Manner Tom% I " � _' O D D (� : ; 1 i ii 1„11 L . MAR 0 5 11997 Job Address: 322 Copperstone Trail Date: 3 -3 -- / v ' Lot: 29 Block: A Subdivision: Copperstone Phase or Section Number: Owner Drees Homes Address: 1521 N. Cooper, Suite 500 Phone #: 817/469-9991 ext 351 Contractor: Same Address: Phone #: Description of Work to be Done Class of Work: ® New ❑ Addition ❑ Alteration ❑ Repair ❑ Demolition New Single Family Residence J_ 166 r L Area 6f Building in Square Feet First Floor 2488 Garage 623 Value of Work to be Performed $284.990 Second Floor 1203 Other GRAY AREA FOR OFFICE USE ONLY NOTICE Permit Fee: Receipt Number: 7 Z, Jr This permit becomes null and void if work or construction authorized is not commenced within 180 days, or construction on work is suspended or abandoned for a period of 180 days Zoning District: Occupancy Classification: at any time after work is commenced. I hereby certify that I have read and examined this application and know the same to be true Approved By: Date: Comments:_,,,,, ZVO and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal, state or local law struction of the performance of construction. MShannon Coles Signature of Contractor or Authorized Agent Print Name Fox Lasiter Frymire Electrical Contractor PlumbingContractor Mechanical Contractor FPMC - 1 (4/94) -11-q'1 / O.M.B. NO. 3067-0077 ELEVATION CERTIFICATE Expires May 31,.996_ FEDERAL EMERGENCY MANAGEMENT AGENCY NATIONAL FLOOD INSURANCE PROGRAM ATTENTION: Use of this certificate does not provide a waiver of the flood insurance purchase requirement. This form is used only to provide elevation information necessary to ensure compliance with applicable community floodplain management ordinances, to determine the proper insurance premium rate, and/or to support a request for a Letter of Map Amendment or Revision (LOMA or LOMR). Instructions for completing this form can be found on the following pages. BUILDING OWNER'S NAME Drees Homes SECTION A PROPERTY INFORMATION I FOR INSURANCE COMPANY USE POLICY NUMBER STREET ADDRESS (Including Apt., Unit, Suite and/or Bldg. Number) OR P.O. ROUTE AND BOX NUMBER COMPANY NAIC NUMBER 322 Copperstone Trail OTHEP DESCRIPTION (Cot and Block Numbers, etc.) ifs Z2 Lot 29, Block A, Copperstone -_ _ XKXXXX CITY STATE ZIP CODE _ Coppell Texas SECTION B FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Provide the following from the proper FIRM (See Instructions): 1. COMMUNITY NUMBER 2. PANEL NUMBER 3. SUFFIX 4. DATE OF FIRM INDEX 5. FIRM ZONE 6. BASE FLOOD ELEVATION 480170 0010 E LOMB 1/25/95 X (in AO Zones, use depth) '. Indicate the elevation datum system used on the FIRM for Base Flood Elevations (BFE): FK I NGVD '29 [- I Other (describe on back) 3. For Zones A or V, where no BFE is provided on the FIRM, and the community has established a BFE for this building site, indicate the community's BFE: I I I I U. U feet NGVD (or other FIRM datum -see Section B, Item 7). SECTION C BUILDING ELEVATION INFORMATION 1. Using the Elevation Certificate Instructions, indicate the diagram number from the diagrams found on Pages 5 and 6 that best describes the subject building's reference level 2(a). FIRM Zones Ai -A30, AE, AH, and A (with BFE). The top of the reference level floor from the selected diagram is at an elevation of I __L_ I I U.0 feet NGVD (or other FIRM datum -see Section B, Item 7). (b). FIRM Zones V1430, VE, and V (with BFE). The bottom of the lowest horizontal structural member of the reference level from the selected diagram, is at an elevation of I_ _1-[ 1-1_ 1.1 1 feet NGVD (or other FIRM datum -see Section B, Item 7). (c). FIRM Zone A (without BFE). The floor used as the reference level from the selected diagram is .I feet above [ ) or below U (check one) the highest grade adjacent to the building. (d). FIRM Zone AO. The floor used as the reference level from the selected diagram is [ -j j . feet above [-) or below � (check one) the highest grade adjacent to the building. If no flood depth number is available, is the building's lowest floor (reference level) elevated in accordance with the community's floodplain management ordinance? [ I Yes [ I No [ 1 Unknown 3. Indicate the elevation datum system used in determining the above reference level elevations: I I NGVD '29 � I Other (describe under Comments on Page 2). (NOTE: If the elevation datum used in measuring the elevations is different than that used on the FIRM [see Section B, Item 7], then convert the elevations to the datum system used on the FIRM and show the conversion equation under Comments on Page 2.) 4. Elevation reference mark used appears on FIRM: F1 Yes Ll No (See Instructions on Page 4) 5. The reference level elevation is based on: 1XI actual construction 1 1 construction drawings (NOTE: Use of construction drawings is only valid if the building does not yet have the reference level floor in place, in which case this certificate will only be valid for the building during the course of construction. A post -construction Elevation Certificate will be required once construction is complete.) 6. The elevation of the lowest grade immediately adjacent to the building is: L_1_14167 1. 61 feet NGVD (or other FIRM datum -see Section B, Item 7). SECTION D COMMUNITY INFORMATION 1. If the community official responsible for verifying building elevations specifies that the reference level indicated in Section C, Item 1 is not the "lowest floor" as defined in the community's floodplain management ordinance, the elevation of the building's "lowest floor" as defined by the ordinance is: LI I -_ - _ _ .I I feet NGVD (or other FIRM datum -see Section B, Item 7). 2. Date of the start of construction or substantial improvement __ ' FEMA Form 81-31, MAY 93 REPLACES ALL PREVIOUS EDITIONS SEE REVERSE SIDE FOR CONTINUATION SECTION E CERTIFICATION This certification is to be signed by a land surveyor, engineer, or architect who is authorized by state or local law to certify elevation information when the elevation information for Zones Al—A30, AE, AH, A (with BFE),V1—V30,VE, and V (with BFE) is required. Community officials who are authorized by local law or ordinance to provide floodplain management information, may also sign the certification. In the case of Zones AO and A (without a FEMA or community issued BFE), a building official, a property owner, or an owner's representative may also sign the certification. Reference level diagrams 6, 7 and 8 - Distinguishing Features—If the certifier is unable to certify to breakaway/non-breakaway wall, enclosure size, location of servicing equipment, area use, wall openings, or unfinished area Feature(s), then list the Feature(s) not included in the certification under Comments below. The diagram number, Section C, Item 1, must still be entered. I certify that the information in Sections 8 and C on this certificate represents my best efforts to interpret the data available. 1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. CERTIFIER'S NAME LICENSE NUMBER (or Affix Seal) Richard C. Maki _ Tx. Reg. 4587 TITLE COMPANY NAME Reg. Prof. Land Surveyor Maki and Associates,nr. ADDRESS CITY STATE ZIP 3521 W. Pioneerparkway Sui E,__ArlingtonTexas 76013 ___ SIGNATOR DATE PHONE 3-25-97 (817)274-6883 Copies should be made of this Certificate for: 1) community official, 2) insurance agent/company, and 3) building owner. COMMENTS: According to the HUD Flood Insurance_ Rate MapLomm. _Panel No_____ 480170 0010E, revised to reflrct LOMR dated Jan. 25, 1995, this lot is in Clear Zone X. The recorded plat for Copperstone shows a Min. Finish Floor Elevation requirement of 464.4 feet, a vertical control survey determined the finish floor elevation of the wood forms on this lot to be468.60 . Bench Mark: RM 196, Elev. 467.22'. ON WITH ON PILES, SLAB BASEMENT PIERS, OR COLUMNS A V A A V ZONES ZONES ZONES ZONES ZONES REFERENCE REFERENCE BASE LEVEL REFERENCE LEVEL FLOOD LEVEL ELEVATION BASE .`"` ' ''` ADJACENT:'. REFERENCE BASE FLOOD FLOOD GRADE LEVEL ELEVATION REFERENCE ADJACENT ELEVATION LEVEL GRADE + ..;:-:: ADJACENT:: �!1 GRADE. The diagrams above illustrate the points at which the elevations should be measured in A Zones and V Zones. Elevations for all A Zones should be measured at the top of the reference level floor. Elevations for all V Zones should be measured at the bottom of the lowest horizontal structural member. Page 2 Q' Q' S 31'10'51"E 85.00' I Q o W Al � o 0 1 . I � � v �� * .1 `1i ' I C) Q z W AGGR. Q o o DRIVE �/ �v 17'6" mt 1 "? 35'4-1/ ,n x 25'0" 16'3-1/ CONC. N PATIO I �D Z 14'-4"1 <V 28'11"CROSLEY "C" x 3'1-3/4 PLAN #2489 0 o IONAL BAY M MARKET o 15' 11" M cD WIND W ® NOOK x ` Cv 51'11" 0 xnl AGGR. N 7' 4' o 6,11" -,,PATIO N U) x 7 CV x 21'-3" 17'1" 24'0" (MIN.) I 7 4" 11'1 � ASHBROOKE "B" �f N #2862 =*0� NETTLES RES. / i� N i � OVERALL: 61'11"x69'11" FP:467.3 FF:468.0 MIN. FF:464.4 M%A 27'10" 811" 13'5" 61'11" / COVERED PORCH 0 12'10-1/2" 7'3"X3'9-1/2" / 25'-C± `V 12'5" 15'10- 1 /2" / �y. G / y 30�'�• ' /' / N 40 t 'OD Q I - N 2.85 A 0' Vi1l.,E5M� 48 � 2� a2' �Q 52 - - - ro 8,84.33' `a pi 0, L=500'p ,Aft PROPERTY DESCRIPTION Lot 29, Block A, COPPF_RSTONE, an Addition to the City of Coppell, Dallas County, Texas, according to the Plat recored in Volume 96013, Page 87, Map Records, Dallas County, Texas. Lot 28 S 31 '10'51 " E I 1 54.7• L at 29 1 01 K) 14.2' r I 14.2' I WI O N, Z 30.7' _ _ ement10. / Utility Eos i . - 84.3 'R_500.00 _ l rRA s un R r�N f° COP nonurpent� do n{0tion. 3 ` ter llr'e oO �Ontlroiling rr° urn center ed for was used I, the undersigned, hereby certify that the survey map hereon, and the accompanying description, depicts and describes the results of o careful and accurate survey, made on the ground, and to the best of my knowledge and belief, is a true and correct depiction and description of the property surveyed, and that there are no ipparent encroachments ;,r protrusioa-.s oras:: uou.,dory lines, shortages �,f area or boundary, except as shown hereon. The only easements the undersigned has knowledge, are those as shown, however this property is subject to any and all easements, reservations, and restrictions that may be of record. Any reference to the 100 year flood plain or flood hazard zone, is an estimate based on the data stated h—eer.. and should not be interpreted as a study cr ;:eterminotion of the fiooaing propensities of this prcperly. Nc,te: This survey was performed in connection with the transaction described in: Form Survey, for Drees Homes ( Att: Andy ). JvAi 1 .JiJj) �!��J�i,17��, Jmd, P.O. BOX 14293 ARLINGTON, TEXAS 76094-1293 ( 817 ) 274-6883, Metro ( 817 ) 261-8138 Legend: 0 Iron Rod Found —x—x— Wood or Wire Fence r Iron Rod Set Z'� Control Monurnent All iron rods ore 1/2" rebor unless otherwise noted. I Scale: 1 "= 25' Lot 30 2.85' N 48'21 '41 " W r���pl fT$pj�.0 L N �° •4�ffi77 • v. k ti�•.�as�° �l SUB�� Richard C. Maki Registered Professional Land Surveyor No. 4587 Date: 3/24/97 Job No. 17679-9QV