Loading...
Eckerd's-CS 981217Dear Mike: Sincerer 4 hn Maggiore Vice President 111111 NORTH AMERICAN PROPERTIES SOUTHWEST December 17, 1998 Mr. Mike Martin, P.E. Engineering Department 255 Parkway Blvd. Coppell, TX 75019 -4409 (972) 304 -3679 Re: Eckerd's Store SEC of Denton Tap Road and Parkway Boulevard Coppell, TX As per our conversation, attached is the revised Utility Plan for the Eckerd's. The sanitary sewer is now shown as a direct tie -in to the south. I already have an executed agreement with the Owners of Princeton Park and we are in the process of preparing the easement (both metes and bounds and sketch). The easement should be prepared in the next couple of days but with the holidays, execution should take place right after the first of the year. Let me know if there are any questions. 14990 Landmark Blvd. Suite 300 Dallas, TX 75240 -6729 972/866 -9555 Telephone 972/866 -9888 Fax ��II�� NORTH AMERICAN PROPERTIES SOUTHWEST December 15, 1998 Mr. Tom Wouters Coppell Monticello Partners, Ltd. C/O Realty Capital Corporation 920 South Main Street Suite 170 Grapevine, TX 76051 Re: Eckerd's Construction Adjacent to the Princeton Park Office SEC of Denton Tap Road and Parkway Boulevard Coppell, TX Dear Tom: Attached are our checks as follows: $15,000 for the cross access easement $7,900 for the perpetual use of your sanitary sewer Please sign below indicating receipt of these checks. In addition to the $7,900 for the sewer connection, our attorneys will prepare an easement for you to execute which will include a metes and bounds description and a location sketch. Our contractor, C.A. Walker is having their insurance company prepare an "additionally insured" certificate for Coppell Monticello Partners which should be faxed to you today. Once again we appreciate your cooperation. Sincerely, John N. Maggiore Vice President 14990 Landmark Blvd. Suite 300 Dallas, TX 75240 -6729 972/866 -9=,33 Telephone 972/566 -9588 Fax Accepted: Date 0' J z a SCALE :1" =30' H 1" 3' V J INSTALL co M 10' EASEMENT WILL BE RECORDED WITH CITY COUNTY PRIOR TO FINAL ACCEPTANCE BY CITY STA 0 00 EXISTING 4' DIA. SAN. SEW. MANHOLE F.L.(IN.) 459.90 0 co z J BY LIC PLUMBER N z 0 V GROUND LINE N 0 ai v J W N N 465 460 SANITARY SEWER PROFILE o STA 2 EXIST. F.L.(IN F.F. 467.00 J STA 1 14 EXIST. STD 4' DIA. MA F.L.(IN.) 460.39 7 EXIST (2) 7' X 4' BOX CULVERT EXIST 30" R C P INSTALL 62, OF 6" SAN EXIST 12' INLET EXIST 16" W NHOLE 6" SAFC SEVi .50 LEANOUT 461.19 5 L.F. SEW. r INSTALL 1" CORP. STOP 1" DOM. SERVICE 1" DETECTOR CHECK 1" METER BOX STA 2 85.50 CONN. TO EXIST. SAN. SEW. 707 N 01'00 PROPOSED cnocc ACCESS INSTALL 4"I SAN. SEW. LATERAL BY LIC. F LUMBFR TAP AND VALVE F.H. 3' TO BACK OF CURB R= 275.00\ L =50.28 CB =06 °15'14" E CL= 50.21' _t) sl, IT u STA 3 48 ONSTR. STD 4' DIA. SAN. SEW. MANHOLE SCALE N.T.S. w it $4FH SITE AREA 66289 S.F. 10' ESM'TJ w co r RELOCATE EXIST F.H. ASSEMBLY TO 3' BACK I OF CURB EXIST FH DENTON TAP ROAD DEDICATED 10' SIDEWALK AND UTILITY EASEMENT 180.00' S 01 p0'58" DEDICATED 10' SIDEWALK AND UTILITY EASEMENT SEE DTL BELOW TOWN CENFER BLVD. 4 PVC CONDUIT 2 2" PVC CONDUIT W PULL WIRES EXIST 8" W 11 irrigation meter w/ city approved backfiow preventer DRUG STORE 10,909 SF BLDG SHELL 11,200 SF STA 4 22 CONN. TO BLDG. STUBOUT F.L. 463.0 INSTALL 2 WAY CLEAN OUT 45' WYE AT STA 4 112 SS DOM, W DEDICATED 10' SIDEWALK AND UTILITY EASEMENT F.F.E. 467.0 80' LOADING rE m FIRE R= 5679.70' L= 179.26' CL= 179.25' CB =N 00'06'43" W EXIST 16" W INSTALL 8" FIRELINE ENLARGED CONN. DTL 10' X 20' UTILITY ESMNT AS PER FINAL PLAT 1 INSTALL 8" FIRE LINE TO BUILDING CONNECTION AS SHOWN INSTALL 8" X 8" TAP AND VALVE W/ DOUBLE CHECK VAULT FOR FIRE LINE 1 0 V) 28.28' S 46'00'58" w J 0 z N 1— N x w 0 1" 30'-0" 30 1 EXIST 8" W 80 120 GENERAL NOTES -Water Sanitar Sewer Servires 1 All materials and workmanship shall conform to the current edition of both the "N.C.T.C.O.G. Standard Specifications for Public V■brks Construction" and the "City of Coppell Standard Construction Details and Specifications 2. The contractor shall be responsible for protection of all public utilities included in the construction of this project. All manholes, deanouts, valve boxes, fire hydrants shall be adjusted to proper location and elevation by the contractor during the excavation of the project. 3. The contractor shall be responsible for all field surveying for the line and grade for the entire project. Contractor shall assume that all property comers shall be "pinned and flagged" and that the benchmark shall be recoverable. Surveyor will be presided wth an electronic graphic file for dimensional information. 4. The location of existing utilities indicated on these plans are taken from public records. The exact location and elevation of all public utilities (shown or not shown on the plans) shall be determined by the contractor pnor to the start of construction of any newfadlities. 5. The contractor shall provide field dimensions for underground utilities and seances adequate for preparation of an "as built" drawing. 6. All water and sanitary sewer lines installed under pavement shall be badkfilled in maximum lifts of 8' and compacted to a minimum of 95% of the maximum dry density as defined by ASTM D698 (Standard Proctor), at a moisture content within plus or sinus two (2) percent of the optimum moisture value. 7. Contractor shall be responsible for rraintaining trench safety in accordance wth City of Coppell Standards, Texas State Law and OSHA standards 8 Water mains shall be constructed of AWNA Gass 200 DR 14/ PVC pipe, blue in color. All water mains shall have a minimum cover of 42" belowfinish grade or as required to dear other utilities and obstades. Terra -tape is required 1' above water main. 9 Wien installing water mains at sanitary sewer crossings, no joint of water main shall be within 9' of the centerline of the sanitary sewer pipe. 10 Water mains shall be tested and disinfected in accordance with AVWVA 601. Bactenological Tests shall be the responsibility of the contractor on all new water mains pnor to acceptance. A minimum of one bacteriological quality test is required for every 1000' of water line. The results crust be negative with no (0 per 100 ml) colrform 11 Contractor shall provide adequate thrust blocking and retainer glands with all -thread galvanized rods at all bends and deflections greater than 10 degrees in all mains and all hydrant assemblies. 12. A minimum clearance of 24' shall be provided between water mains and storm sewer inlets. 13 All PVC water mains shall have 6" sand bedding with 6" of sand on each side and 12" of sand on top of pipe 14 Poly -wrap (minimum 8 mil thickness) all ductile iron pipe, MJ fittings, valves, risers, tapping saddles and hydrant lines. Pipe shall be double wrapped at all joints and fends Extend up each services at lease 6 inches 15 Tapping sleeves shall be stainless steel for PVC pipe and ductile iron for n_ ductile iron pipe 16 Fire hydrants shall be located 3' behind back of curb Contractor shall place blue fire lite reflector in centerline of street dosest to fire hydrant 17 Fire hydrant connection (use Meg -A -Lug) to the water main shall consist of a flat flange on the in -line tee connected to a MJ x flange resilient wedge gate valve. 18 Fire hydrants to be painted as required by Fire Marshall 19 Water services shall be located as shown herein and shall be 1" diameter Type K copper. The service shall be provided with two in -line nylon ball cutoff valves equipped with lock wings and contained inside the meter box The water service shall be equipped with a double check, back siphonage device in a separate box meeting the City of Coppell standards All tapping saddles and connection nipples to water yoke shall be bronze Water service lines shall not be spliced under paved areas 20 No compression fittings are allowed on copper service lines 21 All sanitary sewer pipe shall be SDR 35 PVC ASTM D3034 green in color 22 The sanitary sewer service shall be 4" in diameter and have a minimum of 4' of cover and a maximum of 6' of cover at the property line The 4" sanitary sewer wye connection for each lateral shall be encased in concrete per City of Coppell Standard Construction details. Contractor shall paint an "S" on the curb (after paving) indicting sewer laterals WATER AND SANITARY SEWER PLAN O cc J REVISION A CITY COMMENTS 10/02/98 A CITY COMMENTS 10/29/98 0 RELOCATE S.S. 12/16/98 C E -73 DATE 07/24/98 SHEET WATER AND SANITARY SEWER PLAN C -7 DWG FILE PLOT SCALE C E73C07 1 =30' PARKWAY BOULEVARD CONN. AT BUILDING CONN. TO EXIST. PLANNING EXIST 16" W OUT 461.50 1 4" 0 't 0 1 1 1 1 1 1 I r 1 11 SIN NM rte' MI MO Ew 6 "'.5y SLOPE 00 2 +50 EXISTING SAN SEW. L W 3 +00 3 +50 4 +00 V) PRIVATE SANITARY SEWER 0' J z a SCALE :1" =30' H 1" 3' V J INSTALL co M 10' EASEMENT WILL BE RECORDED WITH CITY COUNTY PRIOR TO FINAL ACCEPTANCE BY CITY STA 0 00 EXISTING 4' DIA. SAN. SEW. MANHOLE F.L.(IN.) 459.90 0 co z J BY LIC PLUMBER N z 0 V GROUND LINE N 0 ai v J W N N 465 460 SANITARY SEWER PROFILE o STA 2 EXIST. F.L.(IN F.F. 467.00 J STA 1 14 EXIST. STD 4' DIA. MA F.L.(IN.) 460.39 7 EXIST (2) 7' X 4' BOX CULVERT EXIST 30" R C P INSTALL 62, OF 6" SAN EXIST 12' INLET EXIST 16" W NHOLE 6" SAFC SEVi .50 LEANOUT 461.19 5 L.F. SEW. r INSTALL 1" CORP. STOP 1" DOM. SERVICE 1" DETECTOR CHECK 1" METER BOX STA 2 85.50 CONN. TO EXIST. SAN. SEW. 707 N 01'00 PROPOSED cnocc ACCESS INSTALL 4"I SAN. SEW. LATERAL BY LIC. F LUMBFR TAP AND VALVE F.H. 3' TO BACK OF CURB R= 275.00\ L =50.28 CB =06 °15'14" E CL= 50.21' _t) sl, IT u STA 3 48 ONSTR. STD 4' DIA. SAN. SEW. MANHOLE SCALE N.T.S. w it $4FH SITE AREA 66289 S.F. 10' ESM'TJ w co r RELOCATE EXIST F.H. ASSEMBLY TO 3' BACK I OF CURB EXIST FH DENTON TAP ROAD DEDICATED 10' SIDEWALK AND UTILITY EASEMENT 180.00' S 01 p0'58" DEDICATED 10' SIDEWALK AND UTILITY EASEMENT SEE DTL BELOW TOWN CENFER BLVD. 4 PVC CONDUIT 2 2" PVC CONDUIT W PULL WIRES EXIST 8" W 11 irrigation meter w/ city approved backfiow preventer DRUG STORE 10,909 SF BLDG SHELL 11,200 SF STA 4 22 CONN. TO BLDG. STUBOUT F.L. 463.0 INSTALL 2 WAY CLEAN OUT 45' WYE AT STA 4 112 SS DOM, W DEDICATED 10' SIDEWALK AND UTILITY EASEMENT F.F.E. 467.0 80' LOADING rE m FIRE R= 5679.70' L= 179.26' CL= 179.25' CB =N 00'06'43" W EXIST 16" W INSTALL 8" FIRELINE ENLARGED CONN. DTL 10' X 20' UTILITY ESMNT AS PER FINAL PLAT 1 INSTALL 8" FIRE LINE TO BUILDING CONNECTION AS SHOWN INSTALL 8" X 8" TAP AND VALVE W/ DOUBLE CHECK VAULT FOR FIRE LINE 1 0 V) 28.28' S 46'00'58" w J 0 z N 1— N x w 0 1" 30'-0" 30 1 EXIST 8" W 80 120 GENERAL NOTES -Water Sanitar Sewer Servires 1 All materials and workmanship shall conform to the current edition of both the "N.C.T.C.O.G. Standard Specifications for Public V■brks Construction" and the "City of Coppell Standard Construction Details and Specifications 2. The contractor shall be responsible for protection of all public utilities included in the construction of this project. All manholes, deanouts, valve boxes, fire hydrants shall be adjusted to proper location and elevation by the contractor during the excavation of the project. 3. The contractor shall be responsible for all field surveying for the line and grade for the entire project. Contractor shall assume that all property comers shall be "pinned and flagged" and that the benchmark shall be recoverable. Surveyor will be presided wth an electronic graphic file for dimensional information. 4. The location of existing utilities indicated on these plans are taken from public records. The exact location and elevation of all public utilities (shown or not shown on the plans) shall be determined by the contractor pnor to the start of construction of any newfadlities. 5. The contractor shall provide field dimensions for underground utilities and seances adequate for preparation of an "as built" drawing. 6. All water and sanitary sewer lines installed under pavement shall be badkfilled in maximum lifts of 8' and compacted to a minimum of 95% of the maximum dry density as defined by ASTM D698 (Standard Proctor), at a moisture content within plus or sinus two (2) percent of the optimum moisture value. 7. Contractor shall be responsible for rraintaining trench safety in accordance wth City of Coppell Standards, Texas State Law and OSHA standards 8 Water mains shall be constructed of AWNA Gass 200 DR 14/ PVC pipe, blue in color. All water mains shall have a minimum cover of 42" belowfinish grade or as required to dear other utilities and obstades. Terra -tape is required 1' above water main. 9 Wien installing water mains at sanitary sewer crossings, no joint of water main shall be within 9' of the centerline of the sanitary sewer pipe. 10 Water mains shall be tested and disinfected in accordance with AVWVA 601. Bactenological Tests shall be the responsibility of the contractor on all new water mains pnor to acceptance. A minimum of one bacteriological quality test is required for every 1000' of water line. The results crust be negative with no (0 per 100 ml) colrform 11 Contractor shall provide adequate thrust blocking and retainer glands with all -thread galvanized rods at all bends and deflections greater than 10 degrees in all mains and all hydrant assemblies. 12. A minimum clearance of 24' shall be provided between water mains and storm sewer inlets. 13 All PVC water mains shall have 6" sand bedding with 6" of sand on each side and 12" of sand on top of pipe 14 Poly -wrap (minimum 8 mil thickness) all ductile iron pipe, MJ fittings, valves, risers, tapping saddles and hydrant lines. Pipe shall be double wrapped at all joints and fends Extend up each services at lease 6 inches 15 Tapping sleeves shall be stainless steel for PVC pipe and ductile iron for n_ ductile iron pipe 16 Fire hydrants shall be located 3' behind back of curb Contractor shall place blue fire lite reflector in centerline of street dosest to fire hydrant 17 Fire hydrant connection (use Meg -A -Lug) to the water main shall consist of a flat flange on the in -line tee connected to a MJ x flange resilient wedge gate valve. 18 Fire hydrants to be painted as required by Fire Marshall 19 Water services shall be located as shown herein and shall be 1" diameter Type K copper. The service shall be provided with two in -line nylon ball cutoff valves equipped with lock wings and contained inside the meter box The water service shall be equipped with a double check, back siphonage device in a separate box meeting the City of Coppell standards All tapping saddles and connection nipples to water yoke shall be bronze Water service lines shall not be spliced under paved areas 20 No compression fittings are allowed on copper service lines 21 All sanitary sewer pipe shall be SDR 35 PVC ASTM D3034 green in color 22 The sanitary sewer service shall be 4" in diameter and have a minimum of 4' of cover and a maximum of 6' of cover at the property line The 4" sanitary sewer wye connection for each lateral shall be encased in concrete per City of Coppell Standard Construction details. Contractor shall paint an "S" on the curb (after paving) indicting sewer laterals WATER AND SANITARY SEWER PLAN O cc J REVISION A CITY COMMENTS 10/02/98 A CITY COMMENTS 10/29/98 0 RELOCATE S.S. 12/16/98 C E -73 DATE 07/24/98 SHEET WATER AND SANITARY SEWER PLAN C -7 DWG FILE PLOT SCALE C E73C07 1 =30' PARKWAY BOULEVARD CONN. AT BUILDING CONN. TO EXIST. PLANNING EXIST 16" W OUT 461.50