Loading...
FEMA-EC950320O.M.B. NO. 3067.0077 ELEVATION CERTIFICATE Expire, May 31, 1996 FEDERAL EMERGENCY MANAGEMENT AGENCY NATIONAL FLOOD INSURANCE PROGRAM ATTENTION: Use of this certificate does not provide a waiver of the flood insurance purchase requirement. This form is used only to orovlde elevation information necessary to ensure compliance with applicable community floodplain management ordinances, to determine the proper Insurance premium rate. and/or to support a request for a Letter of Map Amendment or Revision (LOMA or LOMR). Instructions for completing this form can be found on the following pages. SECTION A PROPERTY INFORMATION FOR INSURANCE COMPANY USE 3UILDING OWNER'S NAME POLICY NUMBER CENTENNIAL HOMES, INC. STREET ADDRESS (Inclucing Apt.. Unit. Suite and/or Bldg. Numberl OR P.O. ROUTE AND BOX NUMBER COMPANY NAIC NUMBER 108 Hollywood Drive OTHER DESCRIPTICN (Lot and Block Numoers. etc.) Lot 37, Block D, Lakewood Estates CIN STATE ZIP CODE City of Coppell Texas 75019 SECTION 8 FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Provide the following from the proper FIRM (See Instructions): COMMUNITY NUMBER 2. PANEL NUMBER :. SUFFIX 4, DATE OF FIRM INDEX _. FIRM ZONE 6. BASE FLCOD ELEVATION on AO Zones. use oeotn) 480170 0010 D 10/16/91 ___ --- 7. Indicate the elevation datum system used on the FIRM for Base Flood Elevations (BFE): X NGVD '29 Other (describe on back) 8. For Zones A or V. where no SFE is provided on the FIRM, and the community has established a BFE for this building site. indicate the community's BFE: 448.6 feet NGVD (or other FIRM datum–see Section B, Item 7). SECTION C BUILDING ELEVATION INFORMATION 1. Using the Elevation Certificate Instructions, indicate the diagram number from the diagrams found on Pages 5 and 6 that best describes the subject building's reference level _I_ . 2(a). FIRM Zones Al -A30, AE. AH, and A (with BFE). The top of the reference level floor from the selected diagram is at an elevation of i 450,2 feet NGVD (or other FIRM datum–see Section B. Item 7). (b). FIRM Zones V1 -V30. VE. and V (with BFE). The bottom of the lowest horizontal structural member of the reference level from the selected diagram, is at an elevation of feet NGVD (or other FIRM datum–see Section B. Item 7). (c). FIRM Zone A (without BFE). The floor used as the reference level from the selected diagram is ._ feet above:— or below _ (check one) the highest grade adjacent to the building. (d). FIRM Zone AO. The floor used as the reference level from the selected diagram is ._ feet above'— or below 7 (check one) the highest grade adjacent to the building. If no flood depth number is available, is the building's lowest floor (reference level) elevated in accordance with the community's floodplain management ordinance? '_ Yes i_ No Unknown 3. Indicate the elevation datum system used in determining the above reference level elevations: X NGVD '29 _ Other (describe under Comments on Page 2). (NOTE: If the elevation datum used in measuring the elevations is different than that used on the FIRM (see Section B. Item 77, then convert the elevations to the datum system used on the FIRM and show the conversion equation under Comments on Page 2.) 4. Elevation reference mark used appears on FIRM: Yes X No (See Instructions on Page 4) 5. The reference level elevation is based on: X actual construction _ construction drawings (NOTE: Use of construction drawings is only valid if the building does not yet have the reference level floor in place, in which case this certificate will only be valid for the building during the course of construction. A post -construction Elevation Certificate will be required once construction is complete.) 6. The elevation of the lowest grade immediately adjacent to the building is: 449.4 .feet NGVD (or other FIRM datum -see Section B. Item 7). SECTION D COMMUNITY INFORMATION 1. If the community official responsible for verifying building elevations specifies that the reference level indicated in Section C, Item 1 is not the "lowest floor" as defihed in the community's floodplain management ordinance, the elevation of the building's "lowest floor" as defined by the ordinance is: _ feet NGVD (or other FIRM datum–see Section B. Item 7). ' 2. Date of the start of construction or substantial improvement 3/1/95 FEMA Form 6 1 •31, MAY 93 REPLACES ALL PREVIOUS EDITIONS SEE REVERSE 51DE FOR CONTINUATION SECTION E CERTIFICATION This certification is to be signed by a land surveyor, engineer. or architect who is authorized by state or local law to certify elevation information when the elevation information for Zones Al—A30, AE, AH, A (with 8FE),V1—V30,VE. and V (with BFE) is required. Community officials who are authorized by local law or ordinance to provide floodplain management information. may also sign the certification. In the case of Zones AO and A (without a FEMA or community issued BFE), a building official, a property owner, or an owners representative may also sign the certification. Reference level diagrams 6. 7 and 8 - Distinguishing Features—If the certifier is unable to certify to breakaway/non-breakaway wall. enclosure size. location of servicing equipment. area use. wall openings, or unfinished area Feature(s), then list the Feature(s) not included in the certification under Comments below, The diagram number, Section C, Item 1, must still be entered. certify that the information in Sections B and C on this certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. CERTIFIER'S NAME LICENSE NUMBER (or Affix Seal) Dan B. Ramsey R.P.L.S. No. 4172 TITLE COMPANY NAME AooREss Surveying Manager Jones & Boyd, Inc clrY X00 Dalla Parkway, Suite 3010 DallasSTATE SIGNATURE n /) Texas 75248P tdmi c PHONE March 20 1995 214-248-7676 Copies should be made of this Certificate for ) community official, 2) Insurance agent/company, and 3) building owner. COMMENTS: F ^ •...................••... SU ON WrrH SLAB ON PILFS. BASEMENT PIERS. OR COLUMNS A V A ZONES ZONES A V ZONES ZONES ZONES AEFEAENCE AEFERENCE LEVEL SASE LEVEL REFERENCE FLOOD LEVEL ELEVATION SASE '�'n:'::. • .s,;�: FLOOD • "" • "' ADJACENT :;: .:;.: REFERENCE ELEVATION: '�?v. REFERENCE ADJACENT GMOE i:iAi LEVEL FLOOD LEVEL ELEVATION GRADE i::i:;e'..::i';:''•"''-AWA CENT:•. .....•.�:�::...::.:... ::..•-� :�. � �'i:r�•.`::.;: GRADE The diagrams above illustrate the points at which the elevations should be measured in A Zones and V Zones. Elevations for all A Zones should be measured at the top of the reference level floor. Elevations for all V Zones should be measured at the bottom of the lowest horizontal structural member. Page 2 SENT BY:Jones & Boyd: Inc, ; 2-23-95 : 5:12PM ; 3922999- 4901623,9 3 C _ llt Gj ..:� -I li�ti Siir�C-31 ii 'j LIQ": 3Eirja SCALE: 1 30' 1 1 I 1 za:.� SWPLAM 1 t0' IB RAIMAa[ ! SWTAW SEINER E511T.1 1 a =I II do al Isar I 117-9, toy let? 1 7CARCA�JRAGE 1 E 3 '— LOT 38 _ "1 ao 19 .7.11 r�a41 LOT 38 1 1 I 1 1 I cs 6e.2 ENA LETTER RE( WRU�7, I _ X. (a► li p+O,UF—" 1 l ` NOTE: Maximum Novation drop away from foundation Is 0.8' for 4'I sod remaining slope if steeper than 3:1. retain if steeper than 2:1. Superintendent to oseees actual field conditions. Drive Area: 1423 Sq.Ft. Walk Area: 242 Sq.Ft. Lot Area: 12390 Sq.Ft. Type 'C' Drainage Fence Length: 201' Includes 1 Got* date 02/22/95 ALL ELEVATIONS ARE FINAL OPADE UNLESS OTHERWISE NOTED. EXISTING GRADES ARE DENOTED THUS (XX.X) rev subdiv LAKEWOOD ESTATES lot blk 37 0 Trendmaker Homes address 5757 Alpha Road. Suite 700 108 HOLLYWOOD DRIVE Dallas. Texas 75240 city plan *egwrhaeuver (214) 458-9909 COPPELL, TX., 3169B RIGHT FOUNDATION FORM SURVEY TO AL_t PARTIES 'N•TERESTED IN PREMISES SURVE YEC Thic_erei, r,at �e this -trite, Ide Orr,tr (rr(l of /OB rTc�/yupoo /:re ..,E (2,,ev olero��Del/� dE .tip, /J 37, ��,r Lalewoov" Esta res ad t the („s/,(y OT (�O��e// e,e "1r 1 /v�! li / 500,!7 A e �04► L7pr,. r (1-. �1�QS Y. P*i7� 7hiS �)roperty dire- -0t lie *M tr t1t e ho,rcjar,e-� `,P year • C;a (i a,r ;i,: ccrd-r:] floodway Moi. -.480/70 OD/O ,O ettec've S 020/'I 4S"L-", &g_oo' I i I � M m Vo%:me %Lo57, RzyclooL — &o6 3 Lot 37 6/0 d- 0 3, /OS ffo�aet,✓Qrive Too of `o, -,n Reo. - 4 s0.'7 h Fi 015Ar F/mr ei, ='f�66 � Yoi. 9das� m, "Ie g. 0 a b w M 8.4 yds L r c woo vc- CERTIFICATION The ,lot lereor s a true, -arect and ac— ate -epresentat,or it I he property as determined by the survey, 'te 'ines and dimers:ors of said property being as indicated by the prat, the size, location. OF type of buildings and Improvements are shown, mprovements 'rom •.... being within the Dour doves a' the property, set DOCK tr a .•..... property lines the distances indicated, and there Ire -n encrochments o except os noted ••••••... //ot',sions, `/� 4,0_1 r.AMtit.• ... 2 - , Dan B. Ramsey / .ti. `- . 4172 C9 FESS�"rf0� Registered trot or nr:d S.rveyor No V! r JONES & BOYD, INC. CONSULTING ENGINEERS ' %300 Dallos Parkway, `�u-te �Utu--------- — C?aiiaS, Texas 7`248 - — --- - --- 214-248-766 SCALE DAT1 DRAWN PROJECT VISIONS