Loading...
Town Center L4B1-LR011211ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (9?2) 620-8911 Concrete Compression Test Report Tested For: CONSTRUCTION MANAGEMENT GROUP ATTN: MR. JEFF MILLER 5207 MCKINNEY AVENUE, SUITE 12 DALLAS, TX 75205 Projec~Desc: COPPELL TOWN CENTER, T.?..- O_OP. L , Our Report No.: 01612-40 Issue Date: 12/1112001 FIELD DATA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: SIDEWALK, 8~/V & 22'S FROM THE SW CORNER OF THE BUILDING 11/21/01 10:35 AM 4.75 5.2 (ASTM C-173) 47 11/22/01 PICKED UP BY ALPHA MALEY, DENNIS BEALL Plant Number: 13-3000 Delivery Ticket No.: 13501707 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T~/pe: Spec: T-_st_-d: (Da)m): Lenl~th Width Diameter Sq. In. Load: PSI: 68 LAB C-1231 11/28101 7 12 ' NIA 6 28.27 83670 2950 69 LAB 12/19/01 28 12 N/A 6 28.27 0 70 LAB 12/19/01 28 12 NIA 6 28.27 0 71 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: N/A Notes: CC: HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP Respectfully Submitted By: /~7'~/' of Alpha Testing, Inc. Our rest resulu and repom are for ~he exdudve use of the C..Jient (and ~elr designated receplents o~ file In our office) and shall not be reproduced and/or dimtbuted except with express approval of ALPHA. The use of our name and test resulu must receive our written approval. Test results and reper~ apply only to the samples tested and/or · observed, and are not ImJIcaflve of the qualities of apparenl~y Idenl~cal or dmlbr spedmens.