Loading...
ST9302-LR011203 ALPHA TESTING, INC. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 l enort (972) 620-8911 Tested For: CITY OF COPPELL Our Report No.: 98881-227 ATTN: KEN GRIFFIN Issue Date: 12/03/2001 255 PARKVVAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS FIELD DA TA Placement Location: PAVING, 48'N & 42'E FROM THE SW CORNER OF SANDY LAKE RD. & MCARTHUR Date Placed: 10/24/01 Plant Number: 41-6.0 SK Time Placed: 11:30 AM Delivery Ticket No.: 3009299 Slump (ASTM C-143): 4 Made By: ALPHA Air Content: 5.5 (ASTM C-173) Cured Specification: ASTM C-31 Air Temperature: 68 Specimen Temperature: 72 Date Received: 10/25/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: JOHNSTON, ROBERT Mix Data Submitted By: TXI CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 330 LAB C-1231 10/31/01 7 12 N/A 6 28.27 130950 4630 331 LAB C-1231 . 11/21/01 28 12 N/A 6 28.27 139510 4930 332 LAB C-1231 11/21/01 28 12 N/A 6 28.27 136620 4830 333 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3500 i Results to Date: PASSI Notes: CC: CITY OF COPPELL, ED BELL CONSTRUCTION Our test results and repons are for the exclusive use~of the ~ent (and ~flelr designated recepients on ltle in our ofltce) and shall not be reproduced and/or distrllm~ed except with express approval of ALPHA. The use of our name and test results mus~ receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are no~ Indkative of the qualiUes of apparenUy identical or similar specimens.