ST9302-LR011203 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 l enort
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-227
ATTN: KEN GRIFFIN Issue Date: 12/03/2001
255 PARKVVAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS
FIELD DA TA
Placement Location: PAVING, 48'N & 42'E FROM THE SW CORNER OF SANDY LAKE RD. & MCARTHUR
Date Placed: 10/24/01 Plant Number: 41-6.0 SK
Time Placed: 11:30 AM Delivery Ticket No.: 3009299
Slump (ASTM C-143): 4 Made By: ALPHA
Air Content: 5.5 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 68
Specimen Temperature: 72
Date Received: 10/25/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: JOHNSTON, ROBERT
Mix Data Submitted By: TXI
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
330 LAB C-1231 10/31/01 7 12 N/A 6 28.27 130950 4630
331 LAB C-1231 . 11/21/01 28 12 N/A 6 28.27 139510 4930
332 LAB C-1231 11/21/01 28 12 N/A 6 28.27 136620 4830
333 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3500 i
Results to Date: PASSI
Notes:
CC: CITY OF COPPELL, ED BELL CONSTRUCTION