Freeport NIP(2.2)-LR011213CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94011204.0063 '~"~'"~'"'
Servl~~~'~ 3, 2001 8~1 Ca~nter F~., Sure ~1~
Dallas, Te~s 75247
Cli~: TNANodhAmeri~nc. I''~~ PO~Date: December13,2001 (214) 6~1010
~ ~n: lor~ ~ ~ ~roje~t: 8ales Office & ~arehouse Fac.
~d ~arkway, Suite 440 ' Coppell, l~xas
~lton IX 7500~
~roject ~umb~r: 040~204
~at~ri~l Information Sam~l~ tn~orma~ion
Specified Strength: 3000 psi @ 28 Days
Batch Time: 9:42am
Supplier: TXI
Truck No: 103
Mix I.D. No.: 9505
Plant: 31
Ticket No: 3022791
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, 0 F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
6.75
76
65
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
Sample Time: 11:30am Date Cast: November 13, 2001
Technician: Steve Campbell
Weather Conditions: Cloudy, foggy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Pier C.7-7.3
Placement Location: Piers- B.4-7.2, B.7-7.2, B.9-7.2, C.3-7.3,
C.7-7.3
Specification
Test Method
5-7 ASTM C-143
N/A
ASTM C 1064
ASTM C-1064
Age at
Maximum Compressive
Date Test Load Strength
Tested (days) (lbs) (psi)
1 1 6.00 28.27 11/20/2001
1 2 6.00 28.27 11/20/2001
1 3 6.00 28.27 12/11/2001
1 4 6.00 28.27 12/11/2001
7 70,490 2,490
7 70,220 2,480
Average 2,490
28 92,430 3,270
28 91,880 3,250
Average 3,260
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Steve Campbell
Report Distribution:
(1) TNA North American, Inc.
(1) Carrell Ponle & Yost Architecture
(1) R L Goodson Consulting Engineers
(1) Pacific Builders Inc
(1) FACServices Inc
(1) David Kent
(1) City of Coppell - Bldg Insp
(1) City of Coppell - Constr Insp
Reviewed by:
c.
Eric J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 e,-~w~o~,K.y