Loading...
Freeport NIP(2.2)-LR011214CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0066 Service Date: November 14, 2001 Client: TNA North American, Inc. Attn: Terry Raley 1321 Valwood Parkway, Suite 440 Carrollton TX 75006 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 14, 2001 Project: Sales Office & Warehouse Fac. Coppell, Texas Project Number: 94011204 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:33am Supplier: TXI Truck No: 650 Mix I.D. No.: 9505 Plant: 31 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.00 71 65 Ticket No: 3023909 Sample Information Sample Time: 10:30am Date Cast: November 14, 2001 Technician: Steve Campbell Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier B.7-7.2 Placement Location: Piers B.4-7.2, B.7-7.2, B.9-7.2, C.3-7.2 Specification Test Method 5-7 ASTM C-143 N/A ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 11/21/2001 I 2 6.00 28.27 11/21/2001 1 3 6.00 28.27 12/12/2001 1 4 6.00 28.27 12/12/2001 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 95,230 3,370 7 88,480 3,130 Average 3,250 28 118,380 4,190 28 124,780 4,410 Average 4,300 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Report Distribution: (1) TNA North American, Inc. (1) Carrell Poole & Yost Architecture (1) R L Goodson Consulting Engineers (1) Pacific Builders Inc (1) FACServices Inc (1) David Kent (1) City of Coppell - Bldg Insp (1) City of Coppell - Constr Insp Reviewed by: Inc. Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client Indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.