Freeport NIP(2.2)-LR011214CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94011204.0066
Service Date: November 14, 2001
Client: TNA North American, Inc.
Attn: Terry Raley
1321 Valwood Parkway, Suite 440
Carrollton TX 75006
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: December 14, 2001
Project: Sales Office & Warehouse Fac.
Coppell, Texas
Project Number: 94011204
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 9:33am
Supplier: TXI
Truck No: 650
Mix I.D. No.: 9505
Plant: 31
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
6.00
71
65
Ticket No: 3023909
Sample Information
Sample Time: 10:30am Date Cast: November 14, 2001
Technician: Steve Campbell
Weather Conditions: Cloudy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Pier B.7-7.2
Placement Location: Piers B.4-7.2, B.7-7.2, B.9-7.2, C.3-7.2
Specification
Test Method
5-7 ASTM C-143
N/A
ASTM C1064
ASTM C-1064
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
1 1 6.00 28.27 11/21/2001
I 2 6.00 28.27 11/21/2001
1 3 6.00 28.27 12/12/2001
1 4 6.00 28.27 12/12/2001
Age at
Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 95,230 3,370
7 88,480 3,130
Average 3,250
28 118,380 4,190
28 124,780 4,410
Average 4,300
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Steve Campbell
Report Distribution:
(1) TNA North American, Inc.
(1) Carrell Poole & Yost Architecture
(1) R L Goodson Consulting Engineers
(1) Pacific Builders Inc
(1) FACServices Inc
(1) David Kent
(1) City of Coppell - Bldg Insp
(1) City of Coppell - Constr Insp
Reviewed by:
Inc.
Eric J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
Indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.