NEW_700RiverchaseDrive_75019_128689 BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT Name of PWS:Coppell PWS I.D.:0570040 Address:816 S.Coppell Road Coppell,Texas 75019 Phone:972-462-5150 Contact Person:Jerry Davis Catalog No: TXTCOP-22141 Test Date: 11/30/2020 Result: Failed Reason for Test: New Account Name : Riverchase Golf Club Address of Assembly : 700 Riverchase Drive : Address Type : Commercial Inspection The backflow prevention assembly detailed below has been tested as required by TCEQ regulations and is certified to be operating within acceptable parameters. Type of Assembly :Double Check Valve Frequency :Annual What does this serve? Irrigation Manufacturer :Febco ByPass : Model No :805YD ByPass : Size :1 ByPass : Serial No :B1741 ByPass : Location At:Inside underground vault by main entrance Is the assembly installed in accordance with manufacturer recommendations and/or local codes?Yes Is the assembly installed on a non-potable water supply (auxiliary)?No Reduced Pressure Principle Assembly Type II Assembly Pressure Vacuum Breaker Spilled-Resistant Vacuum BreakerDoubleCheckValveAssembly 1st check 2nd check Relief Valve Bypass Check Air Inlet Check Valve Initial Test Date:11/30/2020 Time:10:15 AM Held at 0 psid Closed Tight Leaked Held at 0 psid Closed Tight Leaked Opened at psid Did not open Held at psid Closed Tight Leaked Opened at psid Did not open Did it fully open Yes No Held at psid Leaked Repairs andMaterialsUsed ** Test After Repair Date: Time: Held at psid Closed Tight Leaked Held at psid Closed Tight Leaked Opened at psid Held at psid Closed Tight Leaked Opened at psid Held at psid ***2nd check:numeric reading required for DCVA only Test gauge used: Potable Make: Wilkins Model: TG5 Serial No.: 05092152 Date Tested for Accuracy: 3/10/2020 Remarks :11/30/2020 Tried to perform an Backflow inspection at Riverchase Golf Club in the city of Coppell.But do to the condition of the 8”control valves,the control valves would not turn to continue on with the Backflow inspection.The control valve handle and steam were wanting to turn together instead of the handle spinning freely down the steam of the 8”control valve.Didnotwanttobrakethesteamfromtheseatofthecontrolvalve.So it is recommended that the entire Backflow assembly andbothofthe8”control valves be replaced do to the condition of the entire assembly.Also this a 8"Febco 805YD maincontainmentbackflowassembly,not a 1"irrigation line as listed above. Firm Name : TDIndustries Licensed Tester : Jon Thomas Firm Address : 13850 Diplomat BPAT License # : BP0014795 Firm Phone No : 972-888-9500 License Expiration Date : 09/21/2021 The above is certified to be true at the time of testing. * Test Records must be kept for at least three years.[30 TAC §290.46(B)] ** Use only manufacturer's replacement parts.