Westbury Manor-LR 990511FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes Report Date: May 11, 1999 PROJECT: wes~ury Manor, Coppelt, Texas Project NO.: 0781-2277 SAMPLE DATE: April 2, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): 70 CONCRETE TEMP. (°F) (AS?M C-10S4): 85 TIME BATCHED: 8:45 am TIME SAMPLED: 9:07 am WEATHER CONDITION: Cloudy LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPLIER: Site PLANT/TRUCK: Batch MIX ID NUMBER: 8284 AIR (%) (ASTM C-231): 4.8 WATER ADDED (gal): 0 SLUMP (in.) (ASTM C.~43): 2.9 Castlebury, alley, station 5+30 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12', 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYUNDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi), ,, WMC 49 7 04/09/99 83000 2940 3600/28 days WMC 50 28 04/30/99 1'14000 4030 WMC 51 28 04/30/99 112000 3960 WMC 52 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~] ~ ~ ~ Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: SMH/rm Distribution: Jesse Blackstone Ryland Homes - Mark Gaines / City of Coppell - Larry Davis- Goodwin & Marshall- David Gregory Site Concrete, Inc. - Metissa Uselding FUGRO SOUTH INC. Reviewed By: ~ FUGRO SOUTH, INC. 2880 Virgo Lane; Dalta~. Texa~ 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: May 11, 1999 PROJECT: Vistas of Coppelt 3, Coppell, Texas Project No.: 0781-2276 SAMPLE DATE: May 3, 1999 CONTRACTOR: Gilco TICKET NO.: 072911 AMBIENT TEMP. (°F): 75 CONCRETE TEMP. (°F) (ASTM C.1064): 71 TIME BATCHED: 10:00 TIME SAMPLED: 10:55 WEATHER CONDITION: Cloudy LOCATION OF PLACEMENT: Paving: CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: 6/941 MIX ID NUMBER: 42 AIR (%) (As'r~ c-231): 3.3 WATER ADDED (gal): 0 SLUMP (in.) (ASTM C.~43): 2.75 Eastbound turn lane into Watchers Trace Drive, sample taken at far west side of turn lane CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED, (pounds) (psi) (psi) VOC 89 7 05/10/99 121000 4280 3600/28 days .. VOC 90 28 05131/99 VOC 91 28 05/31/99 VOC 92 Hold Fracture mode i's (A) unless otherwise noi~l" ' Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~ ~'] ~'~ r--'] Cudng: Methods: ASTM C-39 Fracture: AVXI [/XJ VI LJB c D REMARKS: Technician: David Putman FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: ~ Centex Homes - Robert Poole City of Coppell- Larry Davis Gilco Contracting Inc. - Dale Gilreath