Westbury Manor-LR 990507FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Ryland Homes Westbury Manor, Coppell, Texas SAMPLE DATE: April 7, 1999 Report Date: May 7, 1999 Project No.: 0781-2277 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): 70 CONCRETE TEMP. (°F) (ASTM C-1064): 80 TIME BATCHED: 1:00 pm TIME SAMPLED: 1:20 pm WEATHER CONDITION: LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTU C-~1): WATER ADDED (gal): Partly cloudy SLUMP (in.) (ASTU C-143): Brick inlay at station 10+87 - London Fog On Site CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYUNDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days), TESTED (pounds) (psi) (psi) WMC 61 7 04/14/99 67000 2370 3000/28 days WMC 62 28 05/05/99 97000 3430 WMC 63 28 05105/99 95000 3360 .., WMC 64 Hold ... Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~] [~ [~ [~ Curing: Methods: ASTM C-39 Fracture: A e c D REMARKS: Technician: Bob Shea SMH/kp Distribution: Ryland Homes - Mark Gaines City of Coppell - Larry Davis Goodwin & Marshall - David Gregory Site Concrete, Inc. - Melissa Uselding FUGRO SOUTH INC. Reviewed By: ~