Westbury Manor-LR 990412FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Westbury Manor, Coppell, Texas Report Date: April 12, 1999 Project No.: 0781-2277 i2, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): 75 CONCRETE TEMP. (°F) (ASTM C-10M): 85 TIME BATCHED: 2:00 pm TIME SAMPLED: 2:35 pm WEATHER CONDITION: Cloudy LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASH C-23t): WATER ADDED (gal): SLUMP (in.) (ASTM C-t43): Castlebury Court, station 3+00 Site Batch 8284 4.7 0 3.0 TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) WMC 57 7 04/09/99 ,,107000 3780 3600/28days WMC 58 28 04/30/99 WMC 59 28 04/30199 WMC 60 Hold ' Fracture mode is (A) unless otheMise noted Specifications: Making & ASTM 0-31 Testing ASTM C-143, Typesof ~] [~ ~ ~ Curing: Methods: ASTM C.39 Fracture: A B C D REMARKS: Unit Weight: 147.0 lbs./cu, ft. Technician: Jesse Blackstone FUGRO SOUTH INC. SMH/rm Distribution: Ryland Homes - Mark Gaines / City of Coppell - Larry Davis- Goodwin & Marshall - David Gregory Site Concrete, Inc. - Melissa Uselding Reviewed By: ~ ~ FUGRO SOUTH, INC. 2880 Virgo Lane; Dall~. Texa~ 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Westbury Manor, Coppeil, Texas Report Date: Ap~ 12, 1999 Project No.: 0781-2277 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): 73 CONCRETE TEMP. (°F) (ASTM C-1064): 82 TIME BATCHED: 12:45 pm TIME SAMPLED: 1:14 pm WEATHER CONDITION: Cloudy LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPUER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTU C~1): WATER ADDED (gal): SLUMP (in.) (ASl'~ C.t43): Castlebury Court, station 5+00 Site Batch 48284 4.9 0 3 TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYUNDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (day~) TESTED (pound~) (l:mi) (p~i) , , WMC 53 7 04/09199 100000 3540 3600/28 da),s WMC 54 28 04130/99 WMC 55 28 04/30/99 WMC 56 Hold Fracture mode is (A) unless otherwise noted Speciflca,ons: Making & ASTM C-31 Testing ASTM C-143. Typesof [~ p~] ~ ~ Cudng: Methods: ASTM C-39 Fracture: A B C D REMARKS: Unit Weight: 148.0 lbs./cu, ft. Technician: Jesse Blackstone FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: ,~"7' Ryland Homes - Mark Gaines City of Coppell - Larry Davis Goodwin & Marshall - David Gregory Site Concrete, Inc. - Melissa Uselding