Loading...
Cottonwood Est-CS191218O’BrienEngineering, Inc. 2340 E. Trinity Mills, Ste 220, Carrollton TX 75006 972.233.2288 Ph ⋅ 972.233.2818 Fx obrieneng.com Texas Firm ID # F-3758 SDVOSB | Texas HUB | TxDOT SBE Firm | Since 1987 December 18, 2019 Mr. Kumar Gali, P.E., CFM, D.WRE Assistant Director of Public Works City of Coppell 255 Parkway Coppell, TX 75019 RE: Comments for 125 Cottonwood Drive Lot Improvements, Coppell, Texas OEI Job number: 347.003 Dear Mr. Gali: O’Brien Engineering, Inc. is providing hydraulic analysis on behalf of the Holmes Builders for the new home construction and reshaping of the existing pond at 125 Cottonwood Drive in Coppell, TX. Kimley Horn provided additional comments on behalf of the City of Coppell, dated November 25, 2019. The review comments are summarized below in bolded italics and our responses are noted in plain regular font. 1) The previous comment letter requested the pre-project and post-project HEC-RAS models to be prepared using 100-year ultimate condition flows from the City’s Storm Water Management Study by Halff Associates, Inc. dated 1991 (1991 Study). Flows in the provided HEC-RAS model are inconsistent with the 1991 Study. Per the Cottonwood Branch Plate 5- 14 in Appendix F of the 1991 Study, we assume the flows should be consistent with what is shown below. If you believe otherwise, provide justification. Once the HEC-RAS models are revised, confirm the proposed improvements adhere to the City of Coppell Floodplain Management Ordinance. The 50% AC flows have been revised; however, upon review of the HEC-2 results Master Drainage Study provided to OEI via email on 10/15/2019 (http://weblink.coppelltx.gov/WebLink8/DocView.aspx?id=158093&dbid=1), the flow change locations listed in the table above are not necessarily representative of the model data provided for Cottonwood Branch. The image below is extracted from the 1989 Master Drainage Study for City of Coppell, which OEI received in response to our data request. Also included with this response is an image of the workmap for Cottonwood Branch included in that study. Above the cross section located at River Station 8000, all the flows are the same. The first flow change occurs at River Station 8000. A second flow change occurs at River Station 6710 and that flow volume continues for the remainder of the creek. According to this information, the OEI model reflects the correct flow change locations and for the 100-year ultimate flows. Mr. Kumar Gali, P.E., CFM, D.WRE December 18, 2019 Page 2 of 2 2) There is a Manning’s “n” value of 0.65 on the left overbank of cross section 8793, which is incorrect. Revise the HEC-RAS modeling to remove this error. The 0.65 n-value was revised to 0.065 in the LOB of the pre-project geometry. The n-value of the ROB in both the pre- and post-project geometry was updated to rebalance the continuity of flow in the ROB. Report tables have been updated and valley storage loss for both FEMA and City SMS 100-year flows is reduced to 0.1% or less. The revised HEC-RAS model has been included with this submittal as well as revised tables. Sincerely, O’BRIEN ENGINEERING, INC. Stephen Bolster, P.E., MS, CFM Water Resources Task Manager Attachments HEC-RAS Model Tables Drainage Study Workmap xc: Mr. Kent Collins, Director of Public Works Mr. Terry Holmes, The Holmes Builders Post-Project WSEL - Pre-Project WSEL Post-Project Channel Vel - Pre-Project Channel Vel 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity Units ft fps ft fps ft fps ft fps Column Number ID (1) (2) (3) (4) (5) (6) (5)-(3) (6)-(4) 10130 482.35 7.51 482.35 7.51 482.35 7.51 0.00 0.00 10120 482.30 7.60 482.30 7.60 482.30 7.60 0.00 0.00 9890 479.99 11.17 479.99 11.17 479.99 11.17 0.00 0.00 Sandy Lake Road (U/S)9590 478.16 9.32 478.85 8.42 478.84 8.42 -0.01 0.00 Sandy Lake Road (D/S)9475 478.01 7.19 478.24 6.95 478.24 6.96 0.00 0.01 9233 477.45 6.44 477.83 5.73 477.82 5.74 -0.01 0.01 Immediately U/S of Pond 8863 - - 475.84 5.72 475.67 5.98 -0.17 0.26 Inside U/S edge of Pond 8836 - - 475.66 6.69 475.54 6.24 -0.12 -0.45 Inside Pond U/S of Transition 8813 - - 475.45 6.42 475.38 5.71 -0.07 -0.71 Inside Pond D/S of Transition 8793 - - 475.38 5.56 475.32 4.83 -0.06 -0.73 Inside D/S edge of Pond 8675 - - 474.77 5.50 474.77 5.50 0.00 0.00 Immediately D/S of Pond 8640 - - 474.56 5.75 474.56 5.75 0.00 0.00 8000 473.27 5.11 473.29 5.09 473.29 5.09 0.00 0.00 6710 470.13 4.87 470.13 4.87 470.13 4.87 0.00 0.00 Table 1: Comparison of 1% AC Water Surface Elevations and Channel Velocities on Cottonwood Branch FEMA Flows Description Cross Section Number Effective Pre-Project Post-Project Post-Project WSEL - Pre-Project WSEL Post-Project Channel Vel - Pre-Project Channel Vel 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity 1% AC WSEL Channel Velocity Units ft fps ft fps ft fps ft fps Column Number ID (1) (2) (3) (4) (5) (6) (5)-(3) (6)-(4) 10130 482.77 8.45 482.74 8.51 482.74 8.51 0.00 0.00 10120 482.71 8.58 482.67 8.64 482.67 8.64 0.00 0.00 9890 480.93 10.38 481.21 9.61 481.21 9.61 0.00 0.00 Sandy Lake Road (U/S)9590 478.68 10.61 479.59 9.39 479.59 9.39 0.00 0.00 Sandy Lake Road (D/S)9475 478.51 8.25 478.73 8.00 478.73 8.00 0.00 0.00 9233 477.95 6.81 478.31 6.16 478.31 6.17 0.00 0.01 Immediately U/S of Pond 8863 - - 476.24 6.06 476.09 6.31 -0.15 0.25 Inside U/S edge of Pond 8836 - - 476.07 7.16 475.96 6.73 -0.11 -0.43 Inside Pond U/S of Transition 8813 - - 475.85 6.98 475.78 6.32 -0.07 -0.66 Inside Pond D/S of Transition 8793 - - 475.78 5.91 475.73 5.22 -0.05 -0.69 Inside D/S edge of Pond 8675 - - 475.16 5.84 475.16 5.84 0.00 0.00 Immediately D/S of Pond 8640 - - 474.95 6.18 474.95 6.17 0.00 -0.01 8000 473.63 5.41 473.65 5.38 473.65 5.38 0.00 0.00 6710 470.45 5.01 470.45 5.01 470.45 5.01 0.00 0.00 Table 2: Comparison of 1% AC Water Surface Elevations and Channel Velocities on Cottonwood Branch Ultimate SMS Flows Description Cross Section Number Effective Pre-Project Post-Project