Loading...
Woodlands-LR 950630ALPHA TESTING,, .;. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620-8911 REP(,,RT OF FIELD COMPACTION TESTS ~STEDFOR: N.O.C. [NVESTHENTS, INC. DATE: C/O FINLEY DEVELOPHENT ADDISON, TEXAS 06/30/95 NOODLANDS OF COPPELL 95230-9 PR~ECT: COPPELL, TEXAS OURREPORTNO. TEST DATA: ~STI DA~ E~LEV' IstoLID OPTmUM M~m~ ~B ~p~ m Pr. ACE PERCENT MO~ ~Y DE'N~fTY MOt~ ~Y ~ COMPACTION CO~M~''e NO.[ /DEm'H ~l NUMBER % ~F % 32 06/30 FG-4.0 2 15.3 111.3 15.6 108 97 L-A 33 06/30 FG-2.0 2 15.3 111.3 16.0 107 96 [-A 34 06/30 FG 2 15.3 111.3 16.7 107 96 35 06/30 FG-4.0 2 15.3 111.3 16.2 106 96 [-A 36 06/30 FG 2 15.3 111.3 15.9 106 95 [-A 37 06/30 FG-2.0 2 15.3 111.3 16.0 106 95 38 06/30 FG-4.0 2 15.3 111.3 16.1 108 97 TEST LOCATION: 32 SANITARY SEWER LINE "B" STATION 0+50 33 SANITARY SEWER LINE "8" STATION 1+00 34 SANITARY SEWER LINE "8" STATION 1+50 35 SANITARY SEWER LINE "B" STATION 4+60 36 SANITARY SEWER LINE "C' STATION 1+50 37 SANITARY SEWER LINE "C" STATION i+55 38 SANITARY SEWER LINE "D" STATION 0+50 1. FILL 2. NATURALSUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST