Loading...
PA9702-LR000112 REPORT OF ULTRASONIC NSPECTION DATE OF SERVICE: 01/12/00 REPORT NO.: 0001839 CLIENT NO.: COPPELL PROJECT No,: 94991118 CLIENT: City of Coppel] PROJECT: Coppell Aquatic/Recreation Ctr. 732 DeForest 300 Block of Parkway Blvd Coppell, Texas 75019 Coppell, Texas/Prj. #96051 PAGE NO.: 1 Of 1 REPORT OF INSPECTION INSTRUMENT/SN: QTE 991132 LONG. FREQJSIZE: 2.25 MI-IZ/I" dia. CERTIFICATION DATE: 9-99 SHEAR FREQ./SIZE: 2.25 MHZ/5/8"-70° PURPOSE OF TEST: Weld Inspection CALIBRATION: IIW/DSC Block SPECIFICATION: AWE; D 1.1-98 COUPLANT: Cellulose SCAN SENSmVITY: 86DR TEST METHOD: Angle Beam ITEM QUANTITY DESCRIPTION RESULTS 1 1 Roof Level truss which will span across the indoor pool area on line 9, piece mark T2 a. Top chord splice weld Comply b. Bottom chord splice weld. Comply Technician: R. Walcker, Level II Report Distribution: I"BC ~eerill~ I!lC. (1) City of Coppell (1) City of Coppell - Engineering (1) Brinkley Sargent Architects (1) City of Coppell - Bldg. (1) Turner Engineers (1) City of Coppell - Leisure Serv. Dept. (1) Hisaw &Associates Paul D. Smith, P. E. Senior Project Engineer