PA9702-LR000112 REPORT OF ULTRASONIC NSPECTION
DATE OF SERVICE: 01/12/00 REPORT NO.: 0001839
CLIENT NO.: COPPELL PROJECT No,: 94991118
CLIENT: City of Coppel] PROJECT: Coppell Aquatic/Recreation Ctr.
732 DeForest 300 Block of Parkway Blvd
Coppell, Texas 75019 Coppell, Texas/Prj. #96051
PAGE NO.: 1 Of 1
REPORT OF INSPECTION
INSTRUMENT/SN: QTE 991132 LONG. FREQJSIZE: 2.25 MI-IZ/I" dia.
CERTIFICATION DATE: 9-99 SHEAR FREQ./SIZE: 2.25 MHZ/5/8"-70°
PURPOSE OF TEST: Weld Inspection CALIBRATION: IIW/DSC Block
SPECIFICATION: AWE; D 1.1-98 COUPLANT: Cellulose
SCAN SENSmVITY: 86DR
TEST METHOD: Angle Beam
ITEM QUANTITY DESCRIPTION RESULTS
1 1 Roof Level truss which will span across the indoor
pool area on line 9, piece mark T2
a. Top chord splice weld Comply
b. Bottom chord splice weld. Comply
Technician: R. Walcker, Level II
Report Distribution: I"BC ~eerill~ I!lC.
(1) City of Coppell (1) City of Coppell - Engineering
(1) Brinkley Sargent Architects (1) City of Coppell - Bldg.
(1) Turner Engineers (1) City of Coppell - Leisure Serv. Dept.
(1) Hisaw &Associates Paul D. Smith, P. E.
Senior Project Engineer