Loading...
CF-Coppell Rd SC-LR011126 (3)Hooper Engineering Laboratories, Construction Materials Testing Inc. REPORT OF CONCRETE TESTS CLIENT: Texas Unified Constructors, Inc. PROJECT: Field Service Offices & Maint. Fac., Coppell LOCATION OF POUR SET 1: Plinths for service center building: AA, AA.5 and AA.8 lines LOCATION OF POUR SET 2: JOB NO.: 01.1054 DATE: 26 November 2001 SUPPLIER: Lattimore G.1, G.2, G.3, SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 955 Cement Ticket No. 7111189 Flyash Time Batched 1:24pm Sand Time Sampled 2:15pm in. Concrete Temp. IASTM C1064) 67°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix //1 Admix //2 AEA 54 COMPRESSIVE STRENGTH TESTS (ASTM C39} (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Number Inches Days Date (ASTM C143) Total Load Compressive Required Pounds Strength 28-Day psi Strength 65 5.25 7 1 2/03/01 66 5.25 28 12/24/01 67 5.25 28 1 2/24/01 68 5.25 56 01/21/02 97,800 3460 123,000 4350 125,300 4430 28-Day Average 4390 3OOO TECHNICIAN: DISTRIBUTION: CBC (2:00pm-3:30pm) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214).351-6419 Fax (214) 351-5148