Loading...
CF-Coppell Rd SC-LR011101 (3)Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 01.1054 CLIENT: Texas Unified Constructors, Inc. DATE: 1 November 2001 PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER: Lattimore LOCATION OF POUR SET 1: Piers on service center building: C/7, E.4/7.8, C.6/7.8, F/7.8 and D/8 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 54 Truck No. 1111 Cement 414 Type I Ticket No. 3136078 Flyash 103 Time Batched 2:26pm Sand 1433 Time Sampled 3:3Opm in. Concrete Temp. {ASTM C1064) 77°F 1.0 in. 1850 Air Content (ASTM C231) Water 250 Unit Weight (ASTM C138) Admix //1 Plastocrete 161 @ 15.5 oz. Admix /12 AEA COMPRESSIVE STRENGTH TESTS (ASTM C391 (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 25 5.00 7 11/08/01 84,000 2970 26 5.00 28 11/29/01 1:[0,900 5920 27 5.00 28 11/29/01 113,900 4030 28 5.00 56 12~27~01 131,600 4660 28-Day Average 5980 3000 TECHNICIAN: DISTRIBUTION: EWM (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148