Loading...
CF-Coppell Rd SC-LR011031 (4)Hooper Inc. Engineering Laboratories, Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: Texas Unified Constructors, Inc. DATE: PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER: LOCATION OF POUR SET 1: Piers: F.1/6.5, E.5/6.5, C.7/6.5 and C.2/6.5 LOCATION OF POUR SET 2: 01.1054 31 October 2001 Lattimore SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 805 Cement Ticket No. 6163488 Flyash Time Batched 3:25pm Sand Time Sampled 4:15pm in. Concrete Temp. (ASTM C1064) 72°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA 54 414 Typel 103 1433 1850 250 Plastocrete 161 @ 15.5 oz. COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Number Inches Days Date (ASTM C143) Total Load Compressive Required Pounds Strength 28-Day psi Strength 21 5.50 7 11/07/01 22 5.50 28 11/28/01 23 5.50 28 11/28/01 24 5.50 58 12/26/01 90,100 3190 112,100 3970 105,000 3710 125,.100 4430 28-Day Average 3840 3O00 TECHNICIAN: DISTRIBUTION: CBC (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214).351-6419 Fax (214),351-5148