Loading...
CF-Coppell Rd SC-LR011029 (3)Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Texas Unified Constructors, Inc. PROJECT: Field Service Offices & Maint. Fac., Coppell LOCATION OF POUR SET 1: Piers: G/7, G/6.5, G/5 and F.1/5 on service center building LOCATION OF POUR SET 2: JOB NO.: 01.1054 DATE: 29 October 2001 SUPPLIER: Lattimore SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 938 Cement Ticket No. 7109983 Flyash Time Batched 2:44pm Sand Time Sampled 3:15pm in. Concrete Temp. (ASTM C1064) 71 °F 1.0 in. Air Content IASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA 54 414 Typel 103 1433 1850 250 Plastocrete 161 @ 15.5 oz. COMPRESS/VE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Number Inches Days Date (ASTM Cl 43) Total Load Compressive Required Pounds Strength 28-Day psi Strength 17 5.25 7 11/05/01 18 5.25 28 11/26/01 19 5.25 28 11/26/01 20 5.25 56 12/24/01 106,000 3750 148,300 5250 146,100 5170 155,100: 5490. 28-Day Average 5210 3OO0 TECHNICIAN: DISTRIBUTION: EWM (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214)0351-5148