Gateway BP(2.2)-PN210623BGE PROJECT NO. 8499-00
G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_COVER SHEET.dwg Jun 22, 2021-8:29am mnietoBROWN & GAY ENGINEERS, INC.CITY OF COPPELL, DALLAS COUNTY, TEXASJUNE 2021NATERRA INTERNATIONALLOT 3R, BLOCK AGATEWAY BUSINESS PARK NO. 22595 Dallas Pkwy., Suite 101, Frisco, TX 75034BGE, Inc.TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.com112949BGE, Inc.F-1046BEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESSSUBMITTAL LOGFIRST CITY SUBMITTAL3/29/2021SECOND CITY SUBMITTAL5/6/2021THIRD CITY SUBMITTAL 05/24/2021FOURTH CITY SUBMITTAL06/03/2021FIFTH CITY SUBMITTAL06/09/2021SIXTH CITY SUBMITTAL06/22/2021NATERRA INTERNATIONAL
G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_COVER SHEET.dwg Jun 22, 2021-8:29am mnietoBGE, INC.5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TEXAS 75230ARCHITECTCONTACT: MARK PROSSTEL.: 972-759-1400EMAIL: mpross@pdgarch.net2595 Dallas Pkwy, Suite 101Frisco, TX 75034TBPE Registration No. F-1046BGE, Inc.Frisco, TX 75034TBPE Registration No. F-10461250 SOUTH FREEPORT PARKWAYSFPLP HOLDINGS MANAGEMENT LLCCOPPELL, TEXAS 75081OWNER/DEVELOPERCONTACT: JIN SONGTEL.: 817-403-0303EMAIL: jsong@naterra.comENGINEER/LANDSCAPE ARCHITECTCONTACT: NICK HOBBS l(469) 644-1664EMAIL: nhobbs@bgeinc.comBM#1"X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WESTOF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF AFIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40BM#2"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'WEST OF A POWER POLENORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65BM#3"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WESTOF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33BM#4"X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORMMANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25BENCH MARK LISTSheet List TableSheet NumberSheet TitleC0.0COVER SHEETC0.1GENERAL NOTESC1.0DEMOLITION PLANC2.0EROSION CONTROL PLANC2.1EROSION CONTROL DETAILSC3.0DIMENSION CONTROL AND PAVING PLANC4.0GRADING PLANC5.1PROPOSED DRAINAGE AREA MAPC6.0STORM PLANC6.2STORM PROFILESC6.3STORM CALCULATIONSC7.0UTILITY PLANC7.1UTILITY PROFILESC8.0CITY OF COPPELL CONSTRUCTION DETAILS635GATEWAY BLVDFRITZ DRIVEREGENT BLVDN ROYAL LNFREEPORT PKWY
AIRLINE DRSITEVICINITY MAP(NOT TO SCALE)C8.1CITY OF COPPELL CONSTRUCTION DETAILSC8.2CITY OF COPPELL CONSTRUCTION DETAILSC8.3CITY OF COPPELL CONSTRUCTION DETAILSC8.5CONSTRUCTION DETAILSC5.0EXISTING DRAINAGE AREA MAP (REF. ONLY)SPSITE PLANC6.1ROOF DRAIN PLANRPREPLATC4.1GRADING DETAILSC8.4CITY OF COPPELL CONSTRUCTION DETAILSL0.00LANDSCAPE AREA PLANL1.01TREE PRESERVATION PLANL2.01LANDSCAPE PLANL2.02LANDSCAPE NOTESL2.03LANDSCAPE SPECIFICATIONS AND DETAILSL3.01IRRIGATION PLANL3.02IRRIGATION DETAILSL3.03IRRIGATION SPECIFICATIONS AND LEGENDCITY OF COPPELLAPPROVED FOR GENERALCONFORMANCE TO THE CITY OFCOPPELL STANDARDS.THE GENERAL APPROVAL DOES NOTRELIEVE THE OWNER, ENGINEER, ORCONTRACTOR FROM COMPLYINGWITH ALL SPECIFIC REQUIREMENTSOF THE CITY OF COPPELLSUBDIVISION ORDINANCE.
7.384 Acres
321,659 Square Feet
FRITZ DRIVE
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5 FREEPORT PARKWAY
JOEL
W
I
L
S
O
N
S
U
R
V
E
Y
,
ABSTR
A
C
T
N
O
.
1
5
5
5
S. A. &
M
.
G
.
R
.
R
.
C
O
S
U
R
V
E
Y
,
ABSTR
A
C
T
N
O
.
1
4
3
9
JAME
S
A
.
S
I
M
M
O
N
S
S
U
R
V
E
Y
,
ABSTR
A
C
T
N
O
.
1
2
9
6
P.O.B.G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\SV\04_CAD\8499-00_REPLAT.dwg 2021-05-24-16:14 mpeaceREPLAT
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
BEING A REPLAT OF
LOT 3, BLOCK A, GATEWAY BUSINESS PARK NO. 2
AND BEING OUT OF THE
JAMES A. SIMMONS SURVEY, ABSTRACT NO. 1296 AND
JOEL WILSON SURVEY, ABSTRACT NO. 1555
CITY OF COPPELL, DALLAS COUNTY, TEXAS
MAY 2021
SHEET 1 OF 2
8040200
SCALE: 1" = 40'
(NOT TO SCALE)
VICINITY MAP
LEGEND
D.R.D.C.T DEED RECORDS, DALLAS
COUNTY, TEXAS
O.P.R.D.C.T.OFFICIAL PUBLIC RECORDS,
DALLAS COUNTY, TEXAS
P.O.B.POINT OF BEGINNING
PG.PAGE
VOL.VOLUME
C.M.CONTROLLING MONUMENT
INST. NO.INSTRUMENT NUMBER
GENERAL NOTES:
1.Bearings are based on the Texas State Plane Coordinate System, Texas North Central Zone 4202, North American Datum
of 1983, adjustment realization 2011.
2.The floodplain boundaries are approximate and are not depicted hereon. The subject tract lies within Zone X and Zone AE
as delineated on Flood Insurance Rate Map for Dallas County, Texas and Incorporated Areas, Map No. 48113C0135K
with Map Revised date July 7, 2014, which is the current Flood Insurance Rate Map for the community in which the
property is located.
Zone X - Areas determined to be outside the 0.2% annual chance floodplain
Zone AE (Special flood hazard areas subject to inundation by the 1% annual chance flood event) - Base flood
elevations determined
Floodway - The floodway is the channel of the stream plus any adjacent floodplain areas that must be kept free of
encroachment so that the 1% annual chance flood can be carried without substantial increases in flood heights
3.The purpose of this plat is to revise easements to facilitate new development.
PIGGY BOX LLC
1250 Freeport Parkway
Coppell, TX 75019
Contact: Mr. Jin Song
DEVELOPER / OWNER
BGE, Inc.
2595 Dallas Parkway, Suite 101, Frisco, TX 75034
Tel: 972-464-4800 ● www.bgeinc.com
TBPELS Licensed Surveying Firm No. 10193953
Copyright 2021
ENGINEER / SURVEYOR
Contact: Mark Peace, R.P.L.S.
Telephone: 972-464-4884 —Email: mpeace@bgeinc.com
G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\SV\04_CAD\8499-00_REPLAT.dwg 2021-05-24-16:14 mpeaceSURVEYOR'S CERTIFICATE
That I, Gregory Mark Peace, a Registered Professional Land Surveyor, do hereby certify that I have prepared this plat from an
actual on the ground survey of the land; and the monuments shown hereon were found and/or placed under my personal
supervision in accordance with the platting rules and regulations of the City of Coppell, Texas.
________________________________________
Gregory Mark Peace, RPLS No. 6608
STATE OF TEXAS
COUNTY OF COLLIN
BEFORE ME, the undersigned, a Notary Public in and for the State of Texas, on this day personally appeared Gregory Mark
Peace, known to me to the person whose name is subscribed to the foregoing instrument and acknowledged to me that he
executed the same for the purposes and consideration therein expressed.
GIVEN UNDER MY HAND AND SEAL OF OFFICE this ______ day of ____________________, 2021.
___________________________________________________
NOTARY PUBLIC in and for the STATE OF TEXAS
WITNESS OUR HANDS, this the ______ day of ____________________, 2021.
OWNER'S DEDICATION
STATE OF TEXAS
COUNTY OF DALLAS
NOW, THEREFORE, KNOW ALL MEN BY THESE PRESENTS:
THAT, PIGGY BOX LLC, acting herein by and through its duly authorized manager, does hereby adopt the plat designating the
hereinabove described property as LOT 3R, BLOCK A, GATEWAY BUSINESS PARK NO. 2, an addition to the City of Coppell,
Texas, and does hereby dedicate, in fee simple, to the public use forever, the streets and alleys shown thereon. The streets and
alleys are dedicated for street purposes. The easements and public use areas, as shown, are dedicated to the public use
forever, for the purposes indicated on this plat. No buildings, fences, trees, shrubs, or other improvements or growths shall be
constructed or placed upon, over, or across the easements as shown, except that landscape improvements may be placed in
landscape easements, if approved by the City of Coppell. In addition, utility easements may also be used for the mutual use and
accommodation of all public utilities desiring to use or using the same unless the easement limits the use to particular utilities,
said use by public utilities being subordinate to the public's and City of Coppell's use thereof. The City of Coppell and public utility
entities shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs, or other
improvements or growths which may in any way endanger or interfere with the construction, maintenance, or efficiency of their
respective systems in said easements. The City of Coppell and public utility entities shall at all times have the full right of ingress
and egress to or from their respective easements for the purpose of constructing , reconstructing, inspecting, patrolling,
maintaining, reading meters, and adding to or removing all or parts of their respective systems witho9ut the necessity as any time
of procuring permission from anyone.
This plat approved subject to all platting ordinances, rules, regulations, and resolutions of the City of Coppell, Texas.
WITNESS MY HAND, this ______ day of ______________________, 2021.
By:Piggy Box LLC
By:___________________________________________________
Signature
___________________________________________________
Jin Song, Manager
STATE OF TEXAS
COUNTY OF DALLAS
BEFORE ME, the undersigned, a Notary Public in and for the State of Texas, on this day personally appeared Jin Song, Manager
of Piggy Box LLC, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me
that he executed the same for the purposes and consideration therein expressed.
GIVEN UNDER MY HAND AND SEAL OF OFFICE this ______ day of ____________________, 2021.
___________________________________________________
NOTARY PUBLIC in and for the STATE OF TEXAS
WITNESS OUR HANDS, this the ______ day of ____________________, 2021.
OWNER'S CERTIFICATE
STATE OF TEXAS
COUNTY OF DALLAS
WHEREAS, Piggy Box LLC is the owner of a 7.384-acre tract of land situated in the Joel Wilson Survey, Abstract No. 1555 and
the James A. Simmons Survey, Abstract No. 1296, City of Coppell, Dallas County, Texas; said tract being all of Lot 3, Block A,
Gateway Business Park Addition No. 2, Lots 1R and 3, Block A, an addition to the City of Coppell according to the plat recorded
in Instrument No. 201700240374 of the Official Public Records of Dallas County, Texas; said tract being all of that certain tract of
land described in Special Warranty Deed to Piggy Box LLC recorded in Instrument No. 202100150850 of said Official Public
Records; said 7.384-acre tract being more particularly described by metes and bounds as follows:
BEGINNING, at a 5/8-inch iron rod with "BGE" cap set at the intersection of the south right-of-way line of Fritz Drive (a
57.50-foot-wide right-of-way) and the west right-of-way line of Freeport Parkway (an 80-foot-wide right-of-way); said point being
the northeast corner of said Lot 3, Block A;
THENCE, with the said west right-of-way line of Freeport Parkway and the east line of said Lot 3, Block A, the following three (3)
calls:
South 00 degrees 15 minutes 48 seconds East, a distance of 5.89 feet to a 5/8-inch iron rod with "BGE" cap set for corner
at the beginning of a non-tangent curve to the left;
In a southerly direction, with said curve to the left, having a central angle of 36 degrees 55 minutes 41 seconds, a radius of
306.59 feet, a chord bearing and distance of South 18 degrees 43 minutes 49 seconds East, 194.20 feet, and an arc
distance of 197.60 feet to a 5/8-inch iron rod with "BGE" cap set for corner at the end of said curve;
South 37 degrees 11 minutes 03 seconds East, a distance of 15.40 feet to a 5/8-inch iron rod with "BGE" cap set for
corner; said point being the southeast corner of said Lot 3, Block A and the north corner of Lot 1R, Block A of said
Gateway Business Park No. 2 addition;
THENCE, departing the said west right-of-way line of Freeport Parkway and with the southeast line of said Lot 3, Block A and the
northwest line of said Lot 1R, Block A, the following eight (8) calls:
South 56 degrees 38 minutes 06 seconds West, a distance of 164.39 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 68 degrees 23 minutes 11 seconds West, a distance of 160.87 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 69 degrees 26 minutes 22 seconds West, a distance of 78.87 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 70 degrees 42 minutes 31 seconds West, a distance of 56.49 feet to a 1/2-inch iron rod with illegible cap found for
corner;
South 73 degrees 54 minutes 23 seconds West, a distance of 104.98 feet to a 5/8-inch iron rod with "BGE' cap set for
corner;
South 75 degrees 29 minutes 38 seconds West, a distance of 199.75 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 37 degrees 25 minutes 01 seconds West, a distance of 60.69 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 64 degrees 33 minutes 20 seconds West, a distance of 95.81 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner in the northeast right-of-way line of Interstate Highway 635 (also known as Lyndon B. Johnson Freeway, a variable
width right-of-way); said point being the southwest corner of said Lot 3, Block A, the northwest corner of said Lot 1R, Block
A, and the southeast corner of Lot 1R, Block 1, IAAM Headquarters, an addition to the City of Coppell according to the plat
recorded in Instrument No. 202000153484 of said Official Public Records;
THENCE, North 00 degrees 18 minutes 16 seconds West, departing the said northeast right-of-way line of Interstate Highway
635, with the west line of said Lot 3, Block A and the east line of said Lot 1R, Block 1, a distance of 576.39 feet to a 1/2-inch iron
rod with "HALFF" cap found for corner in the said south right-of-way line of Fritz Drive; said point being the northwest corner of
said Lot 3, Block A and the northeast corner of said Lot 1R, Block 1;
THENCE, with the said south right-of-way line of Fritz Drive and the north line of said Lot 3, Block A, the following three (3) calls:
North 89 degrees 41 minutes 14 seconds East, a distance of 552.48 feet to a 1/2-inch iron rod with "HALFF" cap found for
corner;
South 00 degrees 39 minutes 34 seconds West, with an offset in said south right-of-way line of Fritz Drive and said north
line of Lot 3, Block A, a distance of 13.76 feet to a 1/2-inch iron rod with "HALFF" cap found for corner;
North 89 degrees 44 minutes 14 seconds East, a distance of 210.72 feet to the POINT OF BEGINNING;
CONTAINING: 7.384 acres or 321,659 square feet of land, more or less.
The Replat of LOT 3R, BLOCK A, GATEWAY BUSINESS PARK NO. 2, is hereby approved pursuant to Section 212.0065 of the
Texas Local Government Code and Section 13-1-10 of the Coppell Code of Ordinances. The Director of Community
Development may approve minor plats or replats involving four or fewer lost fronting on a existing street and not requiring the
creation of any new street of the extension of municipal facilities.
__________________________________________________
Director of Community Development Date
ATTEST:
__________________________________________________
Planning and Zoning Secretary Date
Floodplain Development Permit Application No. _____ has been filed with the City of Coppell floodplain administrator on
___________________, 2021.
__________________________________________________
Floodplain Administrator Date of Approval
City of Coppell, Texas
REPLAT
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
BEING A REPLAT OF
LOT 3, BLOCK A, GATEWAY BUSINESS PARK NO. 2
AND BEING OUT OF THE
JAMES A. SIMMONS SURVEY, ABSTRACT NO. 1296 AND
JOEL WILSON SURVEY, ABSTRACT NO. 1555
CITY OF COPPELL, DALLAS COUNTY, TEXAS
MAY 2021
SHEET 2 OF 2
PIGGY BOX LLC
1250 Freeport Parkway
Coppell, TX 75019
Contact: Mr. Jin Song
DEVELOPER / OWNER
BGE, Inc.
2595 Dallas Parkway, Suite 101, Frisco, TX 75034
Tel: 972-464-4800 ● www.bgeinc.com
TBPELS Licensed Surveying Firm No. 10193953
Copyright 2021
ENGINEER / SURVEYOR
Contact: Mark Peace, R.P.L.S.
Telephone: 972-464-4884 —Email: mpeace@bgeinc.com
SURVEYOR'S STATEMENT
I, ________________________________________, verify that all franchise utilities have each been contacted and provided a
copy of the plat and development proposal and all franchise utility easements and/or abandonments are currently shown.
15' T.X.U. ELECTRICCOMPANY EASEMENT(VOL. 99172, PG. 16)D.R.D.C.T.DRAINAGE EASEMENT(INST. NO. 201700240374)O.P.R.D.C.T.10' SANITARY SEWEREASEMENT(INST. NO. 201700240374)O.P.R.D.C.T.WATER LINE EASEMENT(INST. NO. 201700240374)O.P.R.D.C.T.WATER LINE EASEMENT(INST. NO. 201700240374)O.P.R.D.C.T.T.P. & L. EASEMENT(VOL. 71159, PG. 743)D.R.D.C.T.T.P. & L. EASEMENT(VOL. 71159, PG. 743)D.R.D.C.T.VAN NO PARKING NO PARKINGNO PARKING12121211118914141212478ZONING: LI - LIGHT INDUSTRIALLAND USE: WAREHOUSE15' LANDSCAPE SETBACKMH7.384 Acres321,659 Square FeetLOT 3R, BLOCK AGATEWAY BUSINESS PARK NO. 2(INST. NO. 201700240374)O.P.R.D.C.T.LOT 1R, BLOCK AGATEWAY BUSINESS PARK NO. 2(INST. NO. 201700240374)O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.LOT 1R, BLOCK 1IAAM HEADQUARTERS(INST. NO. 202000153484)O.P.R.D.C.T.FRITZ DRIVE(FORMERLY KNOWN AS COTTON ROAD)(57.50-FOOT WIDE RIGHT-OF-WAY)INTERSTATE HIGHWAY 635(ALSO KNOWN AS LYNDON B. JOHNSON FREEWAY)(VARIABLE WIDTH RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)BLOCK 1, LOT 2GATEWAY BUSINESS PARK(VOL. 96129, PG. 3135)D.R.D.C.T.TRACT 1SFPLP HOLDINGS MANAGEMENT, LLC(INST. NO. 201200031715)O.P.R.D.C.T.SFPLP HOLDINGSMANAGEMENT, LLC(INST. NO. 201200037650)O.P.R.D.C.T.BLOCK 1, LOT 1GATEWAY BUSINESS PARK(VOL. 96129, PG. 3135)D.R.D.C.T.S 56
°38
'06
"
W
164
.39
'S 68°23
'11"
W
160
.87
'S 69°26
'22"
W
78
.87
'S 70°42'31" W
56
.49
'S 73°54'23" W 104.98
'S 75°29'38" W 199.75'S 37°25'01" W 60.69'S 64°33'20" W 95.81'N 00°18'16" W 576.39'N 89°41'14" E 552.48'S 00°39'34" W 13.76'N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'S 37°11'03" E 15.40'ZONING: LI - LIGHT INDUSTRIALLAND USE: WAREHOUSEZONING: HC - HIGHWAY COMMERCIALLAND USE: OFFICE/WAREHOUSEZONING: HC - HIGHWAY COMMERCIALLAND USE: VACANTZONING: LI - LIGHT INDUSTRIALLAND USE: VACANT15' LANDSCAPE SETBACK60' BUILDING SETBACK30' BUILDING SETBACK30' BUILDING SETBACK10' LANDSCAPE SETBACK10' LANDSCAPE SETBACK
BFR BFR BFRBFRBFRBFRMHFDCPUMPROOMFHFHFHFHFHR30'R15'R35'R35'R
70'
R
3
0'
R32'R30'R30'R35'R35'R10'PROPOSED INDUSTRIALBUILDING135,331 SF (TOTAL)FFE = 524.0015' LANDSCAPE SETBACK5' SIDEWALK5' SIDEWALK5' SIDEWALKSTAIRSSTAIRSSTAIRSSTAIRSSTAIRSSTAIRSSTAIRSSTAIRSSTAIRSAPPROXIMATE LIMITS OFFLOODWAYPROPOSED 24' FIRELANE, ACCESS ANDUTILITY EASEMENTPROPOSED 24' FIRELANE, ACCESS ANDUTILITY EASEMENTPROPOSED 24' FIRELANE, ACCESS ANDUTILITY EASEMENTPROPOSEDELECTRIC SERVICEAPPROXIMATE LIMITS OF 1%ANNUAL CHANCE FLOOD EVENTRAMP. REF. ARCHPLANS FOR DETAILSCONCRETESCREENING BYARCHITECTGAS STRUCTURES. REF.MEP PLANS FOR DETAILSPROPOSED 8" SEWER±296.6' BETWEEN DRIVEWAYS±134.2' BETWEEN DRIVEWAYS602.5' BETWEEN DRIVEWAYS40' DRIVEWAY26'DRIVEWAY18'18'24'18'±98.7' BETWEEN DRIVEWAYS5.5'9'9'9'9'18'24'18'24'18'18'24'
9'24'9'18'24'93.4'9'9'PROPOSED MONUMENT SIGN.REF. ARCH PLANS FOR DETAILSDOUBLE CHECKBACKFLOW PREVENTORDOUBLE CHECKBACKFLOW PREVENTOREX. DRAINAGEEASEMENT3' CURB CUTAPPROXIMATE LOCATION OFEROSION HAZARD SETBACKPROPOSED BOLLARDSPROPOSED BOLLARDSAPPROXIMATELOCATION OFEROSION HAZARDSETBACKPROPOSED 22PARKING SPACESTO BE DEVELOPEDAT FUTURE DATEPROPOSED DRAINAGE EASEMENTPROPOSED 40' FIRELANE, ACCESS ANDUTILITY EASEMENTR624'VARIABLE WIDTHSIDEWALK EASEMENTR100'R100'LPLPLPLPLPLPGIGIGIGICICICICICIPROPOSED JUNCTION BOXG:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\02_Site Plan\SFLP_SITE PLAN.dwg Mar 15, 2021-2:32pm jhaleBGE, INC.BEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS5310 Harvest Hill Rd., Suite 180PROSS DESIGN GROUP INC.DALLAS, TEXAS 75230ARCHITECTCONTACT: MARK PROSSTEL.: 972-759-1400SITE PLANLOT 3R, BLOCK ANATERRA INTERNATIONALBEING 7.384 ACRES SITUATED IN THE JAMES A. SIMMONS SURVEY,ABSTRACT NO. 1296 AND THE JOEL WILSON SURVEY, ABSTRACTNO. 1555CITY OF COPPELL, DALLAS COUNTY, TEXASMARCH 15, 20212595 Dallas Pkwy, Suite 101Frisco, TX 75034TBPE Registration No. F-1046BGE, Inc.Frisco, TX 75034TBPE Registration No. F-10461250 SOUTH FREEPORT PARKWAYSFPLP HOLDINGS MANAGEMENT LLCCOPPELL, TEXAS 75081OWNER/DEVELOPERCONTACT: RALPH NOVAKTEL.: 817-851-4723ENGINEER/LANDSCAPE ARCHITECTCONTACT: NICK HOBBS l(469) 644-1664GENERAL SITE PLAN NOTES:1.ALL DIMENSIONS ARE TO THE FACE OR CURB UNLESS OTHERWISENOTED.2.ALL FIRE LANE RADII ARE 30-FEET MINIMUM.3.ALL FIRE LANES ARE 24-FEET WIDE MINIMUM.4.ALL SCREENING WILL BE PROVIDED IN ACCORDANCE WITH CITY OFCOPPELL REQUIREMENTS.5.ANY REVISION TO THIS PLAN WILL REQUIRE CITY APPROVAL ANDWILL REQUIRE REVISIONS TO ANY CORRESPONDING PLANS TOAVOID CONFLICTS BETWEEN PLANS.LEGENDPROPERTY LINEEXISTING CONTOURPROPOSED CONTOURFLPROPOSED FIRELANESSPROPOSED SANITARY SEWERWWPROPOSED WATERPROPOSED STORM LINEKEYTYPTYPICALBFRBARRIER FREE RAMPFHFIRE HYDRANTSSMHSEWER MANHOLELPLIGHT POLEPPPOWER POLEESMTEASEMENTNUMBER OF PARKING SPACESSTMHSTORM MANHOLEDIDROP INLETFDCFIRE DEPARTMENT CONNECTION520520EASEMENT LINEPROPOSED FIRE LANE EASEMENTCICURB INLET(NOT TO SCALE)VICINITY MAPPROPOSED RETAINING WALLADMINISTRATIVELY APPROVEDMarch 15, 2021
C0.1GENERAL NOTES GENERAL NOTES FOR CONSTRUCTION ACTIVITIES1.ALL CONSTRUCTION, TESTING, AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY'S CURRENT STANDARDS, DETAILS,AND SPECIFICATIONS.2.TESTING AND INSPECTION OF MATERIALS SHALL BE PERFORMED BY A COMMERCIAL TESTING LABORATORY APPROVED BYTHE CITY. CONTRACTOR SHALL FURNISH MATERIALS OR SPECIMENS FOR TESTING, AND SHALL FURNISH SUITABLEEVIDENCE THAT THE MATERIALS PROPOSED TO BE INCORPORATED INTO THE WORK ARE IN ACCORDANCE WITH THESPECIFICATIONS.3.CONTRACTOR SHALL NOTIFY THE CITY AT LEAST 48 HOURS PRIOR TO BEGINNING ANY CONSTRUCTION.4.CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND APPROVALS PRIOR TO BEGINNING ANYCONSTRUCTION.5.CONTRACTOR MUST KEEP AVAILABLE ON-SITE AT ALL TIMES APPROVED CONSTRUCTION PLANS AND COPIES OF ANYREQUIRED PERMITS ALONG WITH THE CURRENT VERSIONS OF THE FOLLOWING REFERENCES: CITY OF COPPELLENGINEERING STANDARDS, NCTCOG SPECIFICATIONS, TXDOT SPECIFICATIONS, TXDOT STANDARD DRAWINGS.6.ALL SHOP DRAWINGS, WORKING DRAWINGS OR OTHER DOCUMENTS WHICH REQUIRE REVIEW BY THE CITY SHALL BESUBMITTED BY THE CONTRACTOR SUFFICIENTLY IN ADVANCE OF SCHEDULED CONSTRUCTION TO ALLOW NO LESS THAN 14CALENDAR DAYS FOR REVIEW AND RESPONSE BY THE CITY.7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED CONSTRUCTION SURVEYING AND STAKING AND SHALLNOTIFY THE ENGINEER AND CITY OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH ANY WORK.8.CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL SURVEY MARKERS INCLUDING IRON RODS, PROPERTYCORNERS, OR SURVEY MONUMENTS WITHIN THE LIMITS OF CONSTRUCTION AND OUTSIDE ROW DURING CONSTRUCTION.ANY SURVEY MARKERS DISTURBED DURING CONSTRUCTION SHALL BE REPLACED BY THE CONTRACTOR AT NO COST TO THECITY.9.CONTRACTOR SHALL PROVIDE A CONSTRUCTION SCHEDULE WITH WEEKLY PROGRESS REPORTS.10.CONTRACTOR IS RESPONSIBLE FOR KEEPING STREETS AND DRIVEWAYS ADJACENT TO THE PROJECT FREE OF MUD ANDDEBRIS AT ALL TIMES. CONTRACTOR SHALL CLEAN UP AND REMOVE ALL LOOSE MATERIAL RESULTING FROM CONSTRUCTIONOPERATIONS. THE CONTRACTOR SHALL TAKE ALL AVAILABLE PRECAUTIONS TO CONTROL DUST.11.THE EXISTENCE AND LOCATIONS OF THE PUBLIC AND FRANCHISE UTILITIES SHOWN ON THE DRAWINGS WERE OBTAINEDFROM AVAILABLE RECORDS AND ARE APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE DEPTH AND LOCATION OFEXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATING, TRENCHING, OR DRILLING AND SHALL BE REQUIRED TO TAKEANY PRECAUTIONARY MEASURES TO PROTECT ALL LINES SHOWN AND / OR ANY OTHER UNDERGROUND UTILITIES NOT OFRECORD OR NOT SHOWN ON THE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PUBLICAGENCIES AND FRANCHISE UTILITIES 48 HOURS PRIOR TO CONSTRUCTION. (DIG-TESS 1-800-344-8377) THE CONTRACTOR MAYBE REQUIRED EXPOSE THESE FACILITIES AT NO COST TO THE CITY. THE CONTRACTOR WILL BE RESPONSIBLE FOR DAMAGESTO UTILITIES IF THE DAMAGE IS CAUSED BY NEGLIGENCE OR FAILURE TO HAVE LOCATES PERFORMED.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES OR ADJACENT PROPERTIES DURINGCONSTRUCTION. ANY REMOVAL OR DAMAGE TO EXISTING FACILITIES SHALL BE REPLACED OR REPAIRED TO EQUAL ORBETTER CONDITION BY THE CONTRACTOR.13.CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL TEMPORARY AND PERMANENT TRAFFICCONTROL IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE LATEST REVISION OF THE TEXAS MANUAL ONUNIFORM TRAFFIC CONTROL DEVICES (TMUTCD) AND TXDOT BARRICADE AND CONSTRUCTION STANDARDS.14.CONTRACTOR SHALL NOT IMPEDE TRAFFIC ON EXISTING STREETS, DRIVEWAYS, ALLEYS, OR FIRE LANES OPEN TO THEPUBLIC. IN THE EVENT THE CONSTRUCTION WORK REQUIRES THE CLOSURE OF AN EXISTING STREET, ALLEY, OR FIRE LANE,THE CONTRACTOR SHALL REQUEST THE ROAD CLOSURE THROUGH THE CITY TRAFFIC DIVISION A MINIMUM OF 48 HOURS INADVANCE OF THE REQUESTED CLOSURE.15.CONTRACTOR SHALL NOT STORE MATERIALS, EQUIPMENT OR OTHER CONSTRUCTION ITEMS ON ADJACENT PROPERTIES ORRIGHT-OF-WAY WITHOUT THE PRIOR WRITTEN CONSENT OF THE PROPERTY OWNER AND THE CITY.16.TEMPORARY FENCING SHALL BE INSTALLED PRIOR TO THE REMOVAL OF EXISTING FENCING. TEMPORARY FENCING SHALL BEREMOVED AFTER PROPOSED FENCING IS APPROVED BY THE CITY. ALL TEMPORARY AND PROPOSED FENCING LOCATIONSSHALL BE SUBJECT TO FIELD REVISIONS AS DIRECTED BY THE CITY.17.UNUSABLE EXCAVATED MATERIAL, OR CONSTRUCTION DEBRIS SHALL BE REMOVED AND DISPOSED OF OFFSITE AT ANAPPROVED DISPOSAL FACILITY BY THE CONTRACTOR AT HIS EXPENSE.18.CONTRACTOR SHALL AVOID DAMAGE TO EXISTING TREES. WHEN NECESSARY, TREES AND SHRUB TRIMMING FORCONSTRUCTION SHALL BE PERFORMED BY CERTIFIED TREE WORKER OR UNDER THE DIRECTION OF A REGISTEREDLANDSCAPE ARCHITECT OR CERTIFIED ARBORIST.19.EROSION CONTROL DEVICES SHALL BE INSTALLED ON ALL PROJECTS PRIOR TO BEGINNING CONSTRUCTION AND SHALL BEMAINTAINED THROUGHOUT THE PROJECT IN A CONDITION ACCEPTABLE TO THE CITY.20.CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING LANDSCAPE IRRIGATION SYSTEMS. DAMAGE TO EXISTINGIRRIGATION SYSTEMS AND LANDSCAPE MATERIALS SHALL BE RESTORED TO EQUAL OR BETTER CONDITION AT NO COST TOCITY.21.IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN A NEAT AND ACCURATE RECORD OF CONSTRUCTION FOR THE CITY'SRECORDS.GENERAL NOTES FOR PAVING1.ALL PAVING CONSTRUCTION, TESTING, AND MATERIALS, INCLUDING CONCRETE, REINFORCEMENT, JOINTING, AND SUBGRADEPREPARATION AND TREATMENT SHALL BE IN ACCORDANCE WITH THE CITY'S CURRENT STANDARDS, DETAILS, ANDSPECIFICATIONS UNLESS OTHERWISE NOTED.2.ABSOLUTELY NO EARTHWORK, LIME APPLICATION, OR OTHER PREPARATION OF THE SUBGRADE FOR PAVING OF STREETS,ALLEYS, OR FIRE LANES SHALL BE INITIATED WITHOUT AUTHORIZATION FROM THE CITY. THE CITY WILL AUTHORIZE THESUBGRADE WORK IN PREPARATION FOR PAVING AFTER UTILITY TRENCH BACKFILL TESTING HAS BEEN COMPLETED ANDVERIFIED TO MEET THE CITY REQUIREMENTS.3.CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL PEDESTRIAN WORK MEETS OR EXCEEDS THE CURRENT AMERICAN WITHDISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AND THE TEXAS ACCESSIBILITY STANDARDS (TAS). THE CONTRACTORSHALL REMOVE AND REPLACE ANY CONSTRUCTED OR INSTALLED ITEMS NOT MEETING THE CURRENT ADAAG AND TASREQUIREMENTS AT NO ADDITIONAL COST TO THE CITY.GENERAL NOTES FOR STORM DRAIN1.ALL STORM DRAIN CONSTRUCTION, TESTING, AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY'S CURRENTSTANDARDS, DETAILS, AND SPECIFICATIONS UNLESS OTHERWISE NOTED.2.CONTRACTOR SHALL SUBMIT A TRENCH SAFETY PLAN PRIOR TO THE PRE-CONSTRUCTION MEETING.GENERAL NOTES FOR WATER AND WASTEWATER1. ALL WATER AND WASTEWATER CONSTRUCTION, TESTING, AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY'SCURRENT STANDARDS, DETAILS, AND SPECIFICATIONS UNLESS OTHERWISE NOTED.2. CONTRACTOR SHALL SUBMIT A TRENCH SAFETY PLAN PRIOR TO THE PRE-CONSTRUCTION MEETING.3. CONTRACTOR SHALL NOT OPERATE EXISTING VALVES. CONTACT THE CITY'S PUBLIC WORKS DEPARTMENT TO REQUESTVALVE CHANGES.4.ALL FRANCHISE UTILITIES TO BE PLACED A MINIMUM OF 4-FEET FROM WATER UTILITIES.GENERAL NOTES FOR LANDSCAPING1.ALL LANDSCAPING CONSTRUCTION, INSTALLATION, TESTING, AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY'SCURRENT STANDARDS, DETAILS, AND SPECIFICATIONS UNLESS OTHERWISE NOTED.2.WHERE TRANSPLANTING OR TREE REMOVAL IS REQUIRED CONTRACTOR MUST APPLY FOR A TREE PERMIT PRIOR TOOBTAINING A GRADING PERMIT OR SCHEDULING THE PRE-CONSTRUCTION MEETING. CONTACT DEVELOPMENT SERVICESLANDSCAPE ARCHITECT FOR TREE PERMIT.3.PRIOR TO OBTAINING A GRADING PERMIT OR SCHEDULING THE PRE-CONSTRUCTION MEETING, ALL TREE MARKINGS ANDPROTECTIVE FENCING MUST BE INSTALLED BY THE CONTRACTOR AND BE INSPECTED BY THE CITY'S LANDSCAPE ARCHITECT.4.ALL TREES WHICH ARE TO REMAIN ON SITE SHALL BE PROTECTED WITH A 4' TALL BRIGHTLY COLORED PLASTIC FENCEPLACED AT THE DRIP LINE OF THE TREES.5.TREES TO BE REMOVED MAY BE CHIPPED AND USED FOR MULCH ON SITE OR HAULED OFF-SITE. BURNING OF REMOVEDTREES, STUMPS, OR FOLIAGE REQUIRES WRITTEN APPROVAL BY THE FIRE DEPARTMENT.6.PLANT MATERIALS SHALL NOT IMPEDE OR OBSTRUCT VISION OR ROUTE OF TRAVEL FOR VEHICULAR, PEDESTRIAN, ORBICYCLE TRAFFIC ALONG CITY RIGHT-OF-WAY, VISIBILITY EASEMENTS, SIDEWALKS OR OTHER EASEMENTS.7.NO SIGNS, WIRES, OR OTHER ATTACHMENTS OTHER THAN THOSE OF A PROTECTIVE NATURE SHALL BE ATTACHED TO ANYTREE TO REMAIN ON SITE.GENERAL NOTES FOR IRRIGATION1. ALL IRRIGATION CONSTRUCTION, INSTALLATION, TESTING, AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY'SCURRENT STANDARDS, DETAILS, AND SPECIFICATIONS UNLESS OTHERWISE NOTED.2. A PERMIT FROM THE BUILDING INSPECTION DIVISION IS REQUIRED FOR EACH IRRIGATION SYSTEM.3. CONTRACTOR SHALL NOTIFY THE PARKS DEPARTMENT OF ANY MODIFICATION TO THE EXISTING SYSTEM.4. CONTRACTOR SHALL SCHEDULE A MEETING WITH THE PARKS DEPARTMENT TO COORDINATE WORK PRIOR TO ANYDEMOLITION OR REMOVAL OF EXISTING IRRIGATION AND PRIOR TO ANY INSTALLATION OF NEW IRRIGATION.5. CONTRACTOR SHALL LOCATE AND PROTECT ALL EXISTING LANDSCAPE IRRIGATION SYSTEMS. DAMAGE TO EXISTINGIRRIGATION SYSTEMS AND LANDSCAPE MATERIALS SHALL BE RESTORED TO EQUAL OR BETTER CONDITION AT NO COST TOCITY.6. CONTRACTOR SHALL PROGRAM EACH CONTROLLER ZONE BASED ON SPRINKLER TYPE, PLANT VARIETY, SOILCHARACTERISTIC, SLOPE AND SOLAR ORIENTATION AS DESIGNATED ON THE PLANS. THE CONTRACTOR SHALL COORDINATEWITH THE CITY PARKS DEPARTMENT FOR APPROVAL OF THE CONTROLLER SETTINGS.7. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH FRANCHISE UTILITY PROVIDER TO PROVIDE POWER TO EACHIRRIGATION CONTROLLER. CONTRACTOR SHALL HAVE UNDERGROUND POWER LINES INSTALLED FROM POWER SOURCE UPTO THE CONTROLLER. CONTRACTOR SHALL MEET CONTROLLER SPECIFICATIONS FOR POWER REQUIREMENTS.8. CONTRACTOR SHALL SET A TEMPORARY CONTROLLER TO ESTABLISH LANDSCAPE. ONCE LANDSCAPE IS ESTABLISHED,CONTRACTOR SHALL CONTACT THE CITY'S PARKS AND RECREATION DEPARTMENT FOR ASSISTANCE ON INSTALLATION OFINTER SPEC CONTROLLER.GENERAL NOTES FOR EROSION CONTROL & STORM WATER1. STEEL POSTS SHALL NOT BE USED TO INSTALL EROSION CONTROL MEASURES WITHIN CITY ROW.2. NO EQUIPMENT SHALL BE CLEANED ON-SITE, OR OTHER LIQUIDS DEPOSITED AND ALLOWED TO FLOW OVERLAND ORSUBTERRANEAN WITHIN THE LIMITS OF THE CRITICAL ROOT ZONE OF TREES THAT REMAIN ON SITE. THIS INCLUDES PAINT,OIL, SOLVENTS, ASPHALT, CONCRETE, CONCRETE EQUIPMENT WASH WATER, MORTAR OF SIMILAR MATERIALS.3. ASPHALT BAGS SHALL BE PLACED AT CONSTRUCTION ENTRANCES TO PREVENT CURB DAMAGE.4. GEOTEXTILE FABRIC SHALL BE PLACED ON SUBGRADE PRIOR TO STONE PLACEMENT FOR CONSTRUCTION ENTRANCES.OWNER'S NOTES1. THE CITY STANDARD DETAILS ARE INCORPORATED BY REFERENCE INTO CONSTRUCTION DRAWINGS.GEOTECH REPORT BY:REED ENGINEERING GROUPPROJECT NO: 22775DATE: 9/20/2019*INCLUDES ALL REVISIONS AND ADDENDUMSAFTER LISTED DATEREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_GENERAL NOTES.dwg Jun 22, 2021-8:29am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303BM#1"X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WESTOF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF AFIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40BM#2"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'WEST OF A POWER POLENORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65BM#3"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WESTOF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33BM#4"X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORMMANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25BENCH MARK LISTBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046
LEGEND
PROPERTY LINE
EXISTING SANITARY SEWER AND MANHOLE
EXISTING WATER AND FIRE HYDRANT
EXISTING STORM LINE
SS
W W
EXISTING GAS LINEGAS
EXISTING OVERHEAD ELECTRICOHE
EXISTING UNDERGROUND ELECTRICUGE
DEMOLITION NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN. CONTRACTOR TO VERIFY LOCATION OF
EXISTING UTILITIES PRIOR TO CONSTRUCTION.
2.CONTRACTOR TO INSTALL ALL EROSION CONTROL AND TREE
PROTECTION PRIOR TO CONSTRUCTION.
3.ALL WORK AND MATERIALS SHALL COMPLY WITH CITY AND COUNTY
REGULATIONS AS WELL AS O.S.H.A. STANDARDS.
4.CONTRACTOR TO OBTAIN ANY PERMITS NECESSARY FOR
DEMOLITION.
5.THIS PLAN WAS DEVELOPED FROM INFORMATION AVAILABLE AND
SURVEY BY OTHERS. THE CONTRACTOR SHALL REVIEW THE SITE
PRIOR TO DEMOLITION AND NOTIFY ENGINEER OF ANY
DISCREPANCIES.
POWER POLE
SAWCUT LINE
REMOVE EXISTING PAVEMENT
REMOVE EXISTING TREE (55 TOTAL)
EXISTING UTILITY TO BE REMOVEDXXXXX
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54'
2
3
"
W
1
0
4
.
9
8'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'
S 37°11'03" E 15.40'
OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS GAS GASGASGASWWWWWWWWWW12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL
W6" SS 6" SS 6" SS 6" SS 8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS
12" SS12" SS12" SS12" SS12"
SS12"
SS12"
SS12" SSEX. INLET TO BE
CONVERTED TO
JUNCTION BOX
±128 LF OF
CONCRETE CURB
TO BE REMOVED±106 LF OF
CONCRETE CURB
TO BE REMOVED
±282 LF OF EX. DUAL 60" RCP TO
BE REMOVED AFTER PROPOSED
DUAL 60" RCPS ARE INSTALLED
TO MAINTAIN CONVEYANCE
ACROSS THE SITE.
EX. 6" SANITARY
SEWER TO REMAIN
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. POWER POLE
TO REMAIN
EX. OVERHEAD
POWER TO REMAIN
EX. POWER POLE
TO REMAIN
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. UNDERGROUND
COMMUNICATIONS
TO REMAIN
END REMOVAL OF
EX. DUAL 60" RCP
EX. 24" RCP TO
REMAIN
EX. HEADWALL TO
REMAIN
EX. STORM
MANHOLE TO
REMAIN
EX. 12" WATER TO
REMAIN
EX. GAS MAIN TO
REMAIN
EX. 8" SANITARY
SEWER TO REMAIN
EX. 8" STUB TO BE
REMOVED
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. SANITARY
SEWER MANHOLE
TO REMAIN
EX. STORM
MANHOLE TO
REMAIN
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)
FRITZ DRIVE
FREEPORT PARKWAY
(80
-FOOT
W
IDE
R
IGHT
-OF
-WAY
)
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)
BEGIN REMOVAL OF
EX. DUAL 60" RCP
±290 LF OF EX. DUAL 60" RCP TO
BE REMOVED AFTER PROPOSED
DUAL 60" RCPS ARE INSTALLED
TO MAINTAIN CONVEYANCE
ACROSS THE SITE.1.5'EX. 24" RCP TO BE
REMOVED
1.5'BLOCK 1, LOT 2
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
BLOCK 1, LOT 1
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
EX. CURB INLET TO
REMAIN
NORTHING: 7030161.39
EASTING: 2425282.85
NORTHING: 7030404.03
EASTING: 2425149.25
EX. DUAL 60" RCP
TO REMAIN
EX. DUAL 60" RCP
TO REMAIN
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_DEMOLITION PLAN.dwg Jun 22, 2021-8:30am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C1.0DEMOLITION PLAN
VANNO PARKINGNO PARKINGNO PARKING
T
CONCRETE WASHOUT50'30'
515
520 514
514516517518519
515
516
517
518
519 520521
522
523 52152
2
520
521
522
5205205205
2
6
52
7
52
8
529
52052552152252352452652
0
5
2
1
510
515 507508509511512513514516517518519
510
515
520
509511512513514516517518519521522525530524526527528529531532533525524526527528529 5
0
6
5075
0
6
507
508
509
505 5065
0
7
523522523522521521522519519519519519519519521520519518
517
516
515
514
516 515
517518519
516517518519520521522
523
518
519
520
521
522523 52
0
521
7' X 9' LANDING
7' X 5' LANDING
520
525
519
521522523524
526
523
523
522 522
522
503504505506507508509510511
512
513
514
515516517
514
PROPOSED SREENING WALL WITH
STEEL COLUMN PILASTERS. REF.
ARCH PLANS FOR DETAILS.
TRANSFORMER AND WATER TANK
PAD ELEVATIONS = 520.85
IP
PROPOSED STABILIZED
CONSTRUCTION ENTRANCE PER
COPPELL STANDARD DETAIL 1070.
MINIMUM 50' DEPTH AND 30' WIDE.
EX. SANITARY SEWER MANHOLE
PROPOSED JUNCTION BOX
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54
'
2
3
"
W
1
0
4
.
9
8
'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'
S 37°11'03" E 15.40'
PROPOSED
HEADWALL
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)
FRITZ DRIVE
FREEPORT PARKWAY
(80
-FOOT
W
IDE
R
IGHT
-OF
-WAY
)
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
IP
IP
IP
IP
IP
PROPOSED SANITARY SEWER MANHOLE
±1,065 SY OF ARMORMAX ARVS PER
PROPEX GEOSOLUTIONS (TO BE
PERMANENT). SEE SHEET C8.5 FOR DETAIL.
PROPOSED
CHECK DAM
PROPOSED
CHECK DAM
EXISTING
HEADWALL
IP
IP
LEGEND
PROPERTY LINE
IP
EROSION CONTROL NOTES:
1.ALL PROCEDURES AND MATERIALS USED FOR EROSION CONTROL
SHALL BE APPROVED BY THE CITY OF COPPELL WITH CONSENT OF
OWNER.
2.THE LOCATION OF EROSION CONTROL DEVICES AND INSTALLATION
SHALL BE AS SHOWN IN THESE PLANS. ADDITIONAL EROSION
CONTROL AND/OR ADJUSTMENT OF LOCATIONS FOR EROSION
CONTROL MAY OCCUR PER THE CITY OF COPPELL UPON APPROVAL
OF THE OWNER.
3.EACH CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL
EROSION CONTROL DEVICES ALREADY IN PLACE. CONTRACTOR
SHALL REMOVE AND REPLACE EROSION CONTROL AS NEEDED FOR
CONSTRUCTION OR ACCESS. ALL EROSION CONTROL MUST BE IN
PLACE AT THE END OF EACH DAY.
4.ALL PERIMETER SWALES SHALL BE GRADED PRIOR TO EXTENSIVE
ONSITE STREET AND SITE GRADING.
5.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO USE WHATEVER
MEANS ARE NECESSARY TO CONTROL AND LIMIT SILT AND SEDIMENT
LEAVING THE SITE. SPECIFICALLY, THE CONTRACTOR SHALL
PROTECT ALL PUBLIC STREETS, ALLEYS, STREAMS, STORM DRAIN
SYSTEMS AND INLETS FROM EROSION DEPOSITS.
6.EROSION CONTROL DEVICES COULD BE HAY BALES, SILT FENCE,
VEGETATIVE BUFFER STRIP, DIVERSION SWALES (WINDROWS), AND
OTHER DEVICES ALLOWED BY THE EPA. FLOW FROM DIVERSION
SWALES WILL BE FILTERED THROUGH STRUCTURAL CONTROLS SUCH
AS HAY BALES, SILT FENCES, ETC. PRIOR TO BEING RELEASED INTO
PAVED AREAS OR STORM SEWER SYSTEMS.
7.CONTROLS SHOULD BE SELECTED, INSTALLED, AND MAINTAINED IN
ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND PER THE
DETAILS ON THIS SHEET.
8.IF SEDIMENT ESCAPES THE SITE, OFF-SITE ACCUMULATIONS MUST BE
REMOVED AT A FREQUENCY SUFFICIENT TO MINIMIZE OFF-SITE
IMPACTS.
9.SEDIMENT MUST BE REMOVED FROM TRAPS AND PONDS WHEN
DESIGN CAPACITY HAS BEEN REDUCED BY 50%.
10.THIS EROSION CONTROL PLAN AND ACCOMPANYING STORM WATER
POLLUTION PREVENTION PLAN DOES NOT ADDRESS A BATCH PLANT
BEING PLACED ON THIS SITE. IF THE OPERATOR DESIRES COVERAGE
FOR A BATCH PLANT, SOME MODIFICATIONS ARE NECESSARY. A
SEPARATE BATCH PLANT EROSION CONTROL PLAN AND STORM
WATER POLLUTION PREVENTION PLAN MAY BE OBTAINED BY THE
BATCH PLANT OWNER.
11.THIS EROSION CONTROL PLAN AND ACCOMPANYING STORM WATER
PREVENTION PLAN ASSUMES NO EXCESS EXCAVATED MATERIAL WILL
BE PLACED OUTSIDE THE LIMITS OF THIS SITE. MODIFICATIONS TO
THE EROSION CONTROL PLAN AND THE STORM WATER POLLUTION
PREVENTION PLAN WILL BE NECESSARY IF EXCESS EXCAVATED
MATERIAL IS NOT KEPT ON-SITE.
12.APPROXIMATE AREA TO BE DISTURBED IS 7.34 ACRES.
13.CONSTRUCTION ENTRANCE LOCATION TO BE SELECTED BY
CONTRACTOR AND APPROVED BY OWNER.
14.SEED ALL LOTS.
530
530
EXISTING CONTOUR LINE
PROPOSED CONTOUR LINE
SILT FENCE
INLET PROTECTION
CHECK DAM
CONSTRUCTION ENTRANCE
FIRE LANE PAVEMENT
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_EROSION CONTROL PLAN.dwg Jun 22, 2021-8:30am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C2.0EROSION CONTROL PLAN
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_EROSION CONTROL DETAILS.dwg Jun 22, 2021-8:30am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C2.1EROSION CONTROL DETAILS
LEGEND
PROPERTY LINE
GEOTECH REPORT BY:
REED ENGINEERING GROUP
PROJECT NO: 22775
DATE: 9/20/2019
*INCLUDES ALL REVISIONS AND ADDENDUMS
AFTER LISTED DATE
NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN.
2.ALL WORK AND MATERIALS SHALL COMPLY WITH CITY AND COUNTY
REGULATIONS AS WELL AS O.S.H.A STANDARDS.
3.ALL DIMENSIONS ARE TO THE FACE OF CURB UNLESS OTHERWISE
NOTED.
4.ALL FIRE LANE RADII ARE 30-FEET MINIMUM.
5.ALL FIRE LANES ARE 24-FEET WIDE MINIMUM.
6.HANDICAP PARKING AND MARKING SHALL BE IN ACCORDANCE WITH
TAS STANDARDS.
7.REFER TO CITY OF COPPELL CONSTRUCTION DETAILS AND
SPECIFICATIONS.
8.ALL SCREENING SHALL BE IN ACCORDANCE WITH CITY OF COPPELL
REQUIREMENTS.
9.CONTRACTOR TO COORDINATE WITH CITY TRAFFIC ENGINEER PRIOR
TO INSTALLING ROAD SIGNS OR PAVEMENT MARKINGS.
10.REFER TO LANDSCAPE AND ARCHITECTURAL PLANS FOR FINAL
SIDEWALK LAYOUT.
11.CONTRACTOR TO COORDINATE WITH RESPECTIVE COMPANY FOR
ANY RELOCATIONS, INCLUDING POWER POLES, LIGHT POLES, AND
ELECTRICAL BOXES
12.REFERENCE GEOTECHNICAL REPORT FOR BUILDING PAD AND PAVING
SUBGRADE PREPARATION.
KEY
TYP TYPICAL
BFR BARRIER FREE RAMP
FH FIRE HYDRANT
SSMH SEWER MANHOLE
LP LIGHT POLE
PP POWER POLE
ESMT EASEMENT
NUMBER OF PARKING SPACES
STMH STORM MANHOLE
WYE WYE INLET
FDC FIRE DEPARTMENT CONNECTION
EXISTING MANHOLE
EXISTING FIRE HYDRANT
EASEMENT LINE
BARRIER FREE RAMP
PROPOSED CURB INLET
PROPOSED GATE VALVE
FIRE DEPARTMENT CONNECTION
PROPOSED FIRE HYDRANT ASSEMBLY
PROPOSED MANHOLE
PROPOSED DOMESTIC METER
PROPOSED IRRIGATION METER
PROPOSED WYE INLET
POWER POLE
BIKE RACKS
CI CURB INLET
15' T.X.U. ELECTRIC
COMPANY EASEMENT
(VOL. 99172, PG. 16)
D.R.D.C.T.
7.5' SIDEWALK & UTILITY
EASEMENT
(VOL. 99172, PG. 16)
D.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
10' SANITARY SEWER
EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54
'
2
3
"
W
1
0
4
.
9
8'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'
S 37°11'03" E 15.40'
OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPVANNO PARKINGNO PARKINGNO PARKING
12
12
12
11 11
8 9
14
14
12 12
4
7
8
T
CI
CI
CI
CI
CI
GI
GI R30'R30'R70'R 6 0 0 'R3
0'R100'R100'R35'R
3
5
'
R
15'
R10'R5 '
R
5'R 3 0 'R 3 2'R 8'R8'
R
8
'R8'R32'
FH
FH
FH
FH
FH
PROPOSED MONUMENT
SIGN. REF. ARCH PLANS
FOR DETAILS
PROPOSED
HEADWALL
PROPOSED DOMESTIC
METER
PROPOSED DOUBLE
CHECK BACKFLOW
PREVENTOR
PROPOSED DOUBLE
CHECK BACKFLOW
PREVENTOR
FDC
MH
PROPOSED JUNCTION
BOXPROPOSED 5'
SIDEWALK
EX.
MH
EX.
MHEX. CIEX. CI
EX. MH EX. MH
EX. CI EX. CI
30' BUILDING SETBACK
15' LANDSCAPE SETBACK
R 3 5 'R3
5'60'
BU
ILD
ING
SETBACK15'
LANDSCAPE
SETBACK
EX.
MH
EX.
MH
EX.
MH
EX.
MH
40' DRIVEWAY 26'
DRIVEWAY
18'18'24'18'9'9'
9'
9'
18'24'18'24'18'18'24'9'24'9'18'24'93.4'9'9'PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
PROPOSED RAMP. REF.
ARCH PLANS FOR
DETAILS
PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
PROPOSED CONCRETE
STAIRS. REF. ARCH
PLANS FOR DETAILS
5.5'PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
PROPOSED STAIRS. REF.
ARCH PLANS FOR
DETAILS
LP
LP
LP
LP
LP
LP
PROPOSED BOLLARDS
PROPOSED
TRANSFORMER
PROPOSED UTILITY
YARD. REF. MEP PLANS
FOR DETAILS
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
ADA PARKING SPACES
WITH SIGNAGE AND
WHEEL STOPS (2).
ADA PARKING SPACES
WITH SIGNAGE AND
WHEEL STOPS (4).
BFR
BFR
BFRBFRBFR
BFR
PROPOSED
IRRIGATION METER
EX.
MH 5'PROPOSED SIDEWALK
EASEMENT
EX. CI
EXISTING
HEADWALL
APPROXIMATE LIMITS OF
FLOODWAY
APPROXIMATE LIMITS OF 1%
ANNUAL CHANCE FLOOD EVENT
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
PROPOSED DRAINAGE
EASEMENT
DRAINAGE
EASEMENT (INST.
NO. 201700240374)
O.P.R.D.C.T.
LANDSCAPE AREA
LANDSCAPE AREA
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)
FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT W
IDE
R
IGHT-OF-WAY)
GI
CONNECT TO EXISTING
PAVEMENT AND CONSTRUCT
LONGITUDINAL BUTT JOINT
PER CITY OF COPPELL
STANDARD DETAIL 2050
CONNECT TO EXISTING PAVEMENT AND
CONSTRUCT LONGITUDINAL BUTT JOINT PER
CITY OF COPPELL STANDARD DETAIL 2050PROPOSED SIDEWALK
EASEMENT
BLOCK 1, LOT 2
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
BLOCK 1, LOT 1
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.8'25.3'16.4'22'±72 LF OF MAX. 4' MODULAR
CONCRETE BLOCK
RETAINING WALL BY
CONTRACTOR. REF. SHEET
C4.0 FOR DETAILS.
R8'
5.5'
PUMP ROOM
ELECTRICAL
ROOM
PATIO
PATIO
5'5' SIDEWALK
5' SIDEWALK
5'5' X 5' LANDING
5' X 5' LANDING
5' X 5' LANDING
5' SIDEWALK
13.2'10'12'10'12'
5' X 5' LANDING
5' X 5' LANDING
5'
5" REINFORCED PORTLAND
CEMENT CONCRETE, MIN.
COMPRESSIVE STRENGTH OF
3600 PSI AT 28 DAYS
REINFORCED WITH #4 BARS
@ 18" O.C.E.W. WITH
CONSTRUCTION JOINTS NOT
TO EXCEED 15 FEET IN ANY
DIRECTION
LIGHT DUTY
PAVEMENT SECTION
6" REINFORCED PORTLAND
CEMENT CONCRETE, MIN.
COMPRESSIVE STRENGTH OF
4000 PSI AT 28 DAYS
REINFORCED WITH #4 BARS
@ 18" O.C.E.W. WITH
CONSTRUCTION JOINTS NOT
TO EXCEED 15 FEET IN ANY
DIRECTION
FIRE LANE
PAVEMENT SECTION
5"8"6"8"7" REINFORCED PORTLAND
CEMENT CONCRETE, MIN.
COMPRESSIVE STRENGTH OF
4000 PSI AT 28 DAYS
REINFORCED WITH #3 BARS
@ 18" O.C.E.W. WITH
CONSTRUCTION JOINTS NOT
TO EXCEED 15 FEET IN ANY
DIRECTION
HEAVY DUTY
PAVEMENT SECTION
7"8"PARKING FIRE LANE TRUCK COURT
8" REINFORCED PORTLAND
CEMENT CONCRETE, MIN.
COMPRESSIVE STRENGTH OF
3600 PSI AT 28 DAYS
8" SUBGRADE COMPACTED TO A MINIMUM 95%
OF STANDARD PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698) AND STABILIZED WITH
6% MINIMUM BY WEIGHT OF HYDRATED LIME.
REINFORCED WITH #4 BARS
@ 18" O.C.E.W. WITH
CONSTRUCTION JOINTS NOT
TO EXCEED 15 FEET IN ANY
DIRECTION
RIGHT-OF-WAY
PAVEMENT SECTION
8"8"ROW
8" SUBGRADE COMPACTED TO A MINIMUM 95%
OF STANDARD PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698) AND STABILIZED WITH
6% MINIMUM BY WEIGHT OF HYDRATED LIME.
8" SUBGRADE COMPACTED TO A MINIMUM 95%
OF STANDARD PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698) AND STABILIZED WITH
6% MINIMUM BY WEIGHT OF HYDRATED LIME.
8" SUBGRADE COMPACTED TO A MINIMUM 95%
OF STANDARD PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698) AND STABILIZED WITH
6% MINIMUM BY WEIGHT OF HYDRATED LIME.
PROPOSED SIDEWALK PER CITY OF
COPPELL STANDARD DETAIL 2170. SEE
SECTION THIS SHEET.
PAVING LEGEND
PROPOSED PARKING PAVEMENT.
SEE SECTION THIS SHEET.
PROPOSED FIRE LANE PAVEMENT.
SEE SECTION THIS SHEET.
PROPOSED HEAVY DUTY PAVEMENT.
SEE SECTION THIS SHEET.
PROPOSED R.O.W. PAVEMENT PER
CITY OF COPPELL STANDARD DETAILS.
SEE SECTION THIS SHEET.
4" REINFORCED PORTLAND
CEMENT CONCRETE, MIN.
COMPRESSIVE STRENGTH OF
3000 PSI AT 28 DAYS
5" SUBGRADE COMPACTED TO A MINIMUM 95%
OF STANDARD PROCTOR MAXIMUM DRY
DENSITY (ASTM D 698).
REINFORCED WITH #3 BARS
@ 18" O.C.E.W. WITH
CONSTRUCTION JOINTS NOT
TO EXCEED 15 FEET IN ANY
DIRECTION
SIDEWALK
PAVEMENT SECTION
4"5"SIDEWALK
*WIRE MESH REINFORCEMENT IS NOT PERMITTED
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_DIMENSION CONTROL AND PAVING PLAN.dwg Jun 22, 2021-8:31am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C3.0DIMENSION CONTROL ANDPAVING PLANSTOP
R1-1
TYPICAL
STOP SIGN DETAIL
VAN NO PARKING NO PARKINGNO PARKINGT5155205145
1
4
516517518519
515516517518519520 521522523521522 520521522520520520
5265275285295
2
0
525
521
522
523
524526
520521510515507508509511512513514516517518519510515520509511512513514516517518519521522 525 530524 526 527528 529531532533525 524526527528529
506507506507508509505506507523522 523522521521
522FFE: 524.00519519519519519519519521520519
5185175165155145165157.384 Acres321,659 Square FeetLOT 3R, BLOCK AGATEWAY BUSINESS PARK NO. 2(INST. NO. 201700240374)O.P.R.D.C.T.FRITZ DRIVE(FORMERLY KNOWN AS COTTON ROAD)(57.50-FOOT WIDE RIGHT-OF-WAY)INTERSTATE HIGHWAY 635(ALSO KNOWN AS LYNDON B. JOHNSON FREEWAY)(VARIABLE WIDTH RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)SFPLP HOLDINGSMANAGEMENT, LLC(INST. NO. 201200037650)O.P.R.D.C.T.CIEXISTING HEADWALLAPPROXIMATE LIMITS OFFLOODWAY4:1 MAX517518
4:1 MAXCICICICIGIGIGI519-1.00%-1.00%-1.00%-2.70%-2.10-2.50-2.40
-2.00%516517518519520521522523518519520521522523DETAIL ASEE SHEET C4.15205214' MAX HEIGHTMODULARCONCRETE BLOCKRETAINING WALLWITH RAIL520525519521522523524526523523522522522DETAIL DSEE SHEET C4.1PROPOSED MANHOLE TOMATCH FINISHED GRADEPROPOSED STORM JUNCTIONBOX TO MATCH FINISHED GRADEPROPOSED HEADWALL.SLOPES NOT TO EXCEED 4:1503504505
506
507
508 50
9
5
1
0
5115125135145155
1
6
5
1
7±1,065 SF OF ARMORMAXARVS PER PROPEXGEOSOLUTIONS. SEESHEET C8.5 FOR DETAIL.520.95520.29518.89 TG518.89 TG518.89 TG519.50515.48514.95514.35515.57515.38516.12515.95517.52514.43518.07514.88514.48513.39513.52520.36520.36520.29520.74520.00524.00 TOPOF STAIRS520.00521.87 ME522.53 ME522.42 ME522.17 ME520.64 TC521.72520.86521.54520.58521.64521.31519.84519.66519.75521.82521.73521.48521.48521.42 ME521.22 ME521.14 TC521.00521.18521.25521.32521.82521.75519.91520.00524.00 TOPOF STAIRS524.00 TOPOF STAIRS524.00 TOPOF RAMP519.91519.91522.15522.16513.54 TC515.50 TC520.30523.95FFE = 524.00514.66516.00515.12514.53FFE = 524.00FFE = 524.00523.95518.00522.50522.73521.98521.95522.06522.19522.33521.28522.07521.44521.73 ME521.48 ME521.26 ME521.00 ME521.23 ME521.33 ME521.46 ME521.60 ME521.55 ME521.34 MEFFE = 524.00FFE = 524.00FFE = 524.00FFE = 524.00FFE = 524.00521.63FFE = 524.00TOP = 522.43522.88521.98523.95523.95523.95523.95523.95FFE = 524.00517.00FFE = 524.00FFE = 524.00TOP = 516.10FFE = 524.00FFE = 524.00TOP = 518.00FFE = 524.00523.90523.90519.70522.65521.71522.66504.17519.33 TC514APPROXIMATE LIMITS OF 1%ANNUAL CHANCE FLOOD EVENTDETAIL CSEE SHEET C4.1DETAIL BSEE SHEET C4.1LEGENDPROPERTY LINENOTES:1.CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES FORUTILITY RELOCATIONS AND/OR ADJUSTMENTS.2.CONTRACTOR TO ADJUST RIMS AND OTHER ABOVE GROUNDUTILITIES TO PROPOSED GRADE.3.GRADING FOR ALL ACCESSIBLE ROUTES SHALL MEET ADASTANDARDS.4.PRIOR TO PLACING PAVEMENT, CONTRACTOR TO TEST FOR PONDING.ALL AREAS SHALL DRAIN TOWARDS THE INTENDED STORMCOLLECTION STRUCTURE.5.CONTRACTOR TO VERIFY LOCATION OF EXISTING UTILITIES PRIOR TOCONSTRUCTION. NOTIFY ENGINEER OF ANY CONFLICTS THAT AREDISCOVERED IN THE FIELD.6.CONTRACTOR TO PROTECT EXISTING UTILITIES.7.CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS PRIORTO CONSTRUCTION.8.REFERENCE DIMENSION CONTROL PLAN FOR HORIZONTALDIMENSIONS.9.CONTRACTOR TO ENSURE THERE IS POSITIVE DRAINAGE AWAY FROMBUILDINGS.10.REFERENCE GEOTECHNICAL REPORT FOR BUILDING PAD AND PAVINGSUBGRADE PREPARATION.11.CONTRACTOR TO REFER TO ARCHITECTURAL PLANS FOR EXACTBUILDING DIMENSIONS.12.RUNNING SLOPE SHALL NOT EXCEED 5.00%.13.CONTRACTOR TO CONTROL EROSION ALONG PROPERTY LINE DURINGCONSTRUCTION.14.OWNER IS RESPONSIBLE FOR PERIODIC INSPECTION ANDMONITORING OF EROSION PROTECTION SYSTEMS AND SHALL NOTIFYENGINEER IF EVIDENCE OF FAILURE HAS OCCURRED.PROPOSED STORM LINE750750EXISTING CONTOUR LINEPROPOSED CONTOUR LINEEXISTING STORM LINEMATCH EXISTING ELEVATION726.25 ME726.25 TOP726.25 TC726.25 TWPROPOSED TOP OF WALL726.25 EWPROPOSED END OF WALL726.25 TGPROPOSED TOP OF GRATE726.25PROPOSED TOP OF SIDEWALKMATCH EXISTING ELEVATIONPROPOSED TOP OF CURBPROPOSED SPOT ELEVATION726.25 BWPROPOSED BOTTOM OF WALLREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_GRADING PLAN.dwg Jun 22, 2021-8:31am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303BM#1"X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WESTOF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF AFIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40BM#2"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'WEST OF A POWER POLENORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65BM#3"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WESTOF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33BM#4"X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORMMANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25BENCH MARK LISTBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046GRADING PLAN
C4.0
NO PARKING52051
8
519 520.10519.89519.36518.28518.01518.10517.84FFE = 524.00518.62519.93FFE = 524.00TOP = 522.35519.75519.58TW = 522.35BW = 519.88518.88TW = 523.91BW = 518.557' X 9' LANDING7' X 5' LANDING519.75519.58520.00520.00TW = 522.35BW = 519.88TW = 523.91BW = 519.28VANNO PARKINGNO PARKING52352
2 522.94522.76522.78522.60522.48522.30522.32522.14522.17521.99522.06521.88522.45522.63522.67522.40522.56522.71523.28523.15FFE = 524.00519517519.27519.03521.50FFE = 524.00523.95FFE = 524.00TOP = 523.61TW: 523.42BW: 520.50TW: 523.95BW: 520.00TW: 524.00BW: 521.50TW: 523.17BW: 520.60520.82520521EW / TW: 522.59BW: 521.10523.47523.22TW: 523.56BW: 520.00FFE = 524.00T520.00519.47521.29FFE = 524.00FFE = 524.00520.50FFE = 524.00523.32520.59PROPOSED SREENING WALL WITHSTEEL COLUMN PILASTERS. REF.ARCH PLANS FOR DETAILS.TRANSFORMER AND WATER TANKPAD ELEVATIONS = 520.85520.85520.85REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_GRADING PLAN.dwg Jun 22, 2021-8:31am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303BM#1"X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WESTOF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF AFIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40BM#2"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'WEST OF A POWER POLENORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65BM#3"X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WESTOF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33BM#4"X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORMMANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25BENCH MARK LISTBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046GRADING DETAILS
C4.1DETAIL ADETAIL BDETAIL DDETAIL C
C5.0EXISTING DRAINAGE AREAMAPREVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_EXISTING DRAINAGE AREA MAP.dwg Jun 22, 2021-8:31am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
VANNO PARKINGNO PARKINGNO PARKING
T
515
520
514
514516517518519
515
516
517
518
519 520521
522
523 52152
2
520
521
522
5205205205
2
6
52
7
52
8
529
52052552152252352452652
0
5
2
1
510
515 507508509511512513514516517518519
510
515
520
509511512513514516517518519521522525530524526527528529531532533525524526527528529 5
0
6
5075
0
6
507
508
509
505506507
523522523522521521522519519519519519519519521520519518
517
516
515
514
516 515
517518519
516517518519520521522
523
518
519
520
521
522523 52
0
521
7' X 9' LANDING
7' X 5' LANDING
520
525
519
521522523524
526
523
523
522 522
522
503504505506507508509510511
512
513
514
515516517
514
PROPOSED SREENING WALL WITH
STEEL COLUMN PILASTERS. REF.
ARCH PLANS FOR DETAILS.
TRANSFORMER AND WATER TANK
PAD ELEVATIONS = 520.85
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)
FRITZ DRIVE
PROPOSED JUNCTION BOX
INLET A-2
INLET A-1
INLET B-1
INLET B-2
INLET B-3
INLET B-4
INLET B-5
PROPOSED STORM
PROPOSED STORMPROPOSED STORM
7.2
BLDG-2
0.90
6.5
OS-2
0.81
3.1
A-2
0.39
1.2
A-1
0.15
4.4
OS-1
0.55
2.1
B-4
0.26
1.6
B-2
0.20
7.2
B-1
0.89
2.8
B-3
0.35
5.4
B-5
0.68 5.7
BLDG-3
0.71
11.9
BLDG-1
1.49
EXISTING
DRAINAGE
EASEMENT
APPROXIMATE LIMITS OF
FLOODWAY
APPROXIMATE LIMITS OF 1%
ANNUAL CHANCE FLOOD EVENT
PROPOSED HEADWALL
EXISTING HEADWALL
EXISTING 60" RCP
EXISTING 60" RCP
PROPOSED STORM
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54'
2
3
"
W
1
0
4
.
9
8
'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'S 37°11'03" E 15.40'
PRE-PROJECT FLOW: 0 CFS
POST-PROJECT FLOW: 230.33 CFS
PRE-PROJECT FLOW: 226.08 CFS
POST-PROJECT FLOW: 42.90 CFS
DOWNSTREAM FLOWS FROM
SITE DEVELOPMENT:
PRE-PROJECT FLOW: 257.30 CFS
POST-PROJECT FLOW: 279.82 CFS
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)LEGEND
PROPERTY LINE
FLOOD NOTES:
1.ACCORDING TO THE FLOOD INSURANCE RATE MAPS (FIRM) MAP NO.
48113C0155K, DATED 07/07/2014, PREPARED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY (FEMA) FOR DALLAS COUNTY,
TEXAS, THIS PROPERTY IS WITHIN ZONE X AND ZONE AE.
Q = CIA
Q - FLOW IN CUBIC FEET PER SECOND = CFS
C - RUNOFF COEFFICIENT
I - INTENSITY WITH TIME OF CONCENTRATION OF
10 MINUTES
A - DRAINAGE AREA = AREA IN ACRES
DRAINAGE DESIGN CRITERIA
RATIONAL METHOD
100 YEAR DESIGN
RUNOFF IN C.F.S.
DRAINAGE AREA IN ACRES
DRAINAGE AREA NUMBER
4.480.57
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM LINE
750
750
EXISTING STORM LINE
DRAINAGE AREA BOUNDARY
DRAINAGE FLOW DIRECTION
DRAINAGE AREA TABLE
DRAINAGE
AREA NO.
A-1
A-2
B-1
B-2
B-3
B-4
B-5
BLDG-1
BLDG-2
BLDG-3
OS-1
OS-2
AREA
(AC)
0.15
0.39
0.89
0.20
0.35
0.26
0.68
1.49
0.90
0.71
0.55
0.81
C
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
TIME OF
CONCENTRATION (Tc)
10
10
10
10
10
10
10
10
10
10
10
10
INTENSITY 100 YR
(IN/HR)
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
8.88
Q100 (CFS)
1.23
3.13
7.15
1.57
2.76
2.06
5.42
11.90
7.23
5.70
4.41
6.46
COLLECTION POINT
INLET B
INLET A
INLET C
INLET D
INLET E
IINLET F
INLET H
ROOF DRAINS
ROOF DRAINS
ROOF DRAINS
OFFSITE
OFFSITE
C5.1PROPOSED DRAINAGE AREAMAPREVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_PROPOSED DRAINAGE AREA MAP.dwg Jun 22, 2021-8:32am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
LEGEND
PROPERTY LINE
EXISTING SANITARY SEWER AND MANHOLE
EXISTING WATER AND FIRE HYDRANT
SS PROPOSED SANITARY SEWER
W PROPOSED WATER
PROPOSED STORM LINE
EASEMENT LINE
EXISTING STORM LINE
SS
W W
EXISTING GAS LINEGAS
EXISTING OVERHEAD ELECTRICOHE
PROPOSED GATE VALVE
FIRE DEPARTMENT CONNECTION
PROPOSED FIRE HYDRANT ASSEMBLY
PROPOSED MANHOLE
PROPOSED DOMESTIC METER
PROPOSED IRRIGATION METER
PROPOSED GRATE INLET
PROPOSED WYE INLET
EXISTING UNDERGROUND ELECTRICUGE
PROPOSED GAS LINEGAS
PROPOSED CURB INLET
POWER POLE
STORM NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN.
2.REFER TO MEP AND ARCHITECTURAL PLANS FOR CONNECTION TO
DOWNSPOUTS AT BUILDINGS AND FLOWLINES.
3.CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING FLOWLINE
ELEVATIONS DO NOT MATCH THOSE SHOWN ON THE PLAN.
4.CONTRACTOR TO ADJUST MANHOLE RIM ELEVATIONS TO MATCH
FINISH GRADE.
5.CONTRACTOR TO REMOVE SILT AND DEBRIS FROM END OF EXISTING
STORM SEWER PRIOR TO MAKING CONNECTION.
6.REFER TO CITY OF COPPELL CONSTRUCTION DETAILS AND
SPECIFICATIONS.
7.ALL UTILITY STUBS SHOWN SHALL BE PLUGGED 5' PAST PROPOSED
PAVEMENT EDGE OR 5' OUTSIDE THE BUILDING.
8.REFER TO TCEQ DESIGN GUIDELINES FOR ALL UTILITY CROSSINGS.
7.5' SIDEWALK & UTILITY
EASEMENT
(VOL. 99172, PG. 16)
D.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
BLOCK 1, LOT 2
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
BLOCK 1, LOT 1
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54'
2
3
"
W
1
0
4
.
9
8'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'
S 37°11'03" E 15.40'
OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS GAS GASGASGASWWWWWWWWW12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL
6" SS 6" SS 6" SS 6" SS 8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS
12" SS12" SS12" SS12" SS12"
SS12"
SS12"
SS12" SSWWWWWWWWWWWWWWW W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W WWWWWWWWWWSSSSSSSSSSSSSSSSW
W
W W W
W W W WWWW W SSVANNO PARKINGNO PARKINGNO PARKING
T
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)
FRITZ DRIVE
FREEPORT PARKWAY(80-FOOT WIDE
R
IGHT-OF-WAY)
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)1+001+481+002+003+004+005+006+00
6+
3
3
1+001+541+00
1+39
1+34
1+007+691+0
0
2+00
3+004+005+006+007+00PC: 1+48.36
PT: 3+54.92
STA: 1+39.32 STORM LINE A-1
INSTALL:
1 - 5' CURB INLET
TC: 519.33
FL 18" OUT: 514.83
STA: 1+00.00 STORM LINE A
INSTALL:
1 - DOUBLE WINGED
HEADWALL
FL 60" IN: 504.17
STA: 1+03.78 STORM LINE A
STA: 1+00.00 STORM LINE A-1
INSTALL:
1 - 60" X 18" WYE
FL 60" IN: 504.18
FL 18" IN: 505.68
FL 60" OUT: 504.18
STA: 2+27.65 STORM LINE A
STA: 1+00.00 STORM LINE A-2
INSTALL:
1 - 60" X 18" WYE
FL 60" IN: 504.55
FL 18" IN: 506.05
FL 60" OUT: 504.55
STA: 1+53.89 STORM LINE A-2
INSTALL:
1 - 5' CURB INLET
TC: 520.64
FL 18" OUT: 516.14
STA: 3+47.60 STORM LINE A
INSTALL:
2 - 60° BEND
FL 60" IN: 504.94
FL 60" OUT: 504.91
STA: 6+20.50 STORM LINE A
INSTALL:
2 - 50° BEND
FL 60" IN: 505.76
FL 60" OUT: 505.76
STA: 6+33.31 STORM LINE A
CONNECT TO EX. DUAL 60" RCP
INSTALL:
2 - 3' x 5' FORTERRA PRECAST
JUNCTION BOX WITH RISER AND
MANHOLE FOR DUAL 60" RCP.
FL 60" OUT: 505.80
STA: 1+00.00 STORM LINE B
CONNECT TO EXISTING
60". CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION PRIOR
TO CONSTRUCTION.
FL 36" IN: 504.96
STA: 1+48.36 STORM LINE B
INSTALL:
1 - 45° BEND
FL 36" IN: 505.32
FL 36" OUT: 505.32
STA: 3+00.44 STORM LINE B
STA: 1+00.00 STORM LINE B-1
INSTALL:
1 - 36" X 24" WYE
FL 36" IN: 506.46
FL 24" IN: 506.96
FL 36" OUT: 506.46
STA: 1+05.00 STORM LINE B-2
INSTALL:
1 - 45° BEND
FL 18" IN: 509.12
FL 18" OUT: 509.12
STA: 1+48.17 STORM LINE B-2
INSTALL:
1 - 5' CURB INLET
TC: 515.50
FL 18" OUT: 510.23
STA: 5+74.00 STORM LINE B
INSTALL:
1 - 45° BEND
FL 18" IN: 512.37
FL 18" OUT: 512.37
STA: 6+15.71 STORM LINE B
INSTALL:
1 - 3' X 3' GRATE INLET
TOP: 518.89
FL 18" IN: 513.04
FL 18" OUT: 513.04
STA: 6+92.21 STORM LINE B
INSTALL:
1 - 3' X 3' GRATE INLET
TOP: 518.89
FL 18" IN: 514.27
FL 18" OUT: 514.27
STA: 7+68.71 STORM LINE B
INSTALL:
1 - 3' X 3' GRATE INLET
TOP: 518.89
FL 18" OUT: 515.50
STA: 1+33.83 STORM LINE B-1
INSTALL:
1 - 5' CURB INLET
TC: 513.54
FL 24" OUT: 508.39
STA: 3+79.80 STORM LINE B
STA: 1+00.00 STORM LINE B-2
INSTALL:
1 - 24" X 18" WYE
FL 24" IN: 508.74
FL 18" IN: 508.99
FL 24" OUT: 508.74
STA: 5+39.15 STORM LINE B
INSTALL:
1 - 45° BEND
FL 18" IN: 511.81
FL 18" OUT: 511.81
STA: 1+44.93 STORM LINE C
INSTALL:
1 - 10' CURB INLET
TC: 521.14
FL 24" OUT: 516.80
1+001+45
STA: 1+00.00 STORM LINE C
CONNECT TO EXISTING 10' CURB
INLET. INSTALL TRAFFIC
RATED JUNCTION BOX. CONTRACTOR
TO VERIFY HORIZONTAL AND VERTICAL
LOCATION PRIOR TO CONSTRUCTION.
FL 24" IN: 516.70
FL 24" OUT: 516.70
STA: 2+53.06 STORM LINE B
STA: 1+00.00 STORM DRAIN 1
INSTALL:
1 - 36" X 18" WYE
FL 18" IN: 506.86
FL 36" IN: 506.11
FL 36" OUT: 506.11
STA: 3+84.80 STORM LINE B
PIPE SIZE CHANGE
FL 18" IN: 509.32
FL 24" OUT: 508.82
STA: 3+05.44 STORM LINE B
PIPE SIZE CHANGE
FL 24" IN: 507.54
FL 36" OUT: 506.54
SEE ROOF DRAIN PLAN. SHEET C6.1
SEE ROOF DRAIN PLAN. SHEET C6.1
SEE ROOF DRAIN
PLAN. SHEET C6.1
0.22%
0.30%0.30%0.30%18.72%0.30%
23.27%1.61%1.61%1.61%1
.
6
1%
1.61%
1.6 1%4.22%0 .7 5 %
0 .7 5 %0.7
5
%
2.00%2.00%2.00%2.00%
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_STORM PLAN.dwg Jun 22, 2021-8:32am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C6.0STORM PLAN
LEGEND
PROPERTY LINE
EXISTING SANITARY SEWER AND MANHOLE
EXISTING WATER AND FIRE HYDRANT
SS PROPOSED SANITARY SEWER
W PROPOSED WATER
PROPOSED STORM LINE
EASEMENT LINE
EXISTING STORM LINE
SS
W W
EXISTING GAS LINEGAS
EXISTING OVERHEAD ELECTRICOHE
PROPOSED GATE VALVE
FIRE DEPARTMENT CONNECTION
PROPOSED FIRE HYDRANT ASSEMBLY
PROPOSED MANHOLE
PROPOSED DOMESTIC METER
PROPOSED IRRIGATION METER
PROPOSED GRATE INLET
PROPOSED WYE INLET
EXISTING UNDERGROUND ELECTRICUGE
PROPOSED GAS LINEGAS
PROPOSED CURB INLET
POWER POLE
STORM NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN.
2.REFER TO MEP AND ARCHITECTURAL PLANS FOR CONNECTION TO
DOWNSPOUTS AT BUILDINGS AND FLOWLINES.
3.CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING FLOWLINE
ELEVATIONS DO NOT MATCH THOSE SHOWN ON THE PLAN.
4.CONTRACTOR TO ADJUST MANHOLE RIM ELEVATIONS TO MATCH
FINISH GRADE.
5.CONTRACTOR TO REMOVE SILT AND DEBRIS FROM END OF EXISTING
STORM SEWER PRIOR TO MAKING CONNECTION.
6.REFER TO CITY OF COPPELL CONSTRUCTION DETAILS AND
SPECIFICATIONS.
7.ALL UTILITY STUBS SHOWN SHALL BE PLUGGED 5' PAST PROPOSED
PAVEMENT EDGE OR 5' OUTSIDE THE BUILDING.
8.REFER TO TCEQ DESIGN GUIDELINES FOR ALL UTILITY CROSSINGS.
7.5' SIDEWALK & UTILITY
EASEMENT
(VOL. 99172, PG. 16)
D.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
BLOCK 1, LOT 2
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
BLOCK 1, LOT 1
GATEWAY BUSINESS PARK
(VOL. 96129, PG. 3135)
D.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54'
2
3
"
W
1
0
4
.
9
8'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'
S 37°11'03" E 15.40'
OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCUGCGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS GAS GASGASGASWWWWWWWWW12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL 12" WL
6" SS 6" SS 6" SS 6" SS 8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS
12" SS12" SS12" SS12" SS12"
SS12"
SS12"
SS12" SSWWWWWWWWWWWWWWW W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W WWWWWWWWWWSSSSSSSSSSSSSSSSW
W
W W W
W W W WWWW W SSVANNO PARKINGNO PARKINGNO PARKING
T
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)
FRITZ DRIVE
FREEPORT PARKWAY(80-FOOT WIDE
R
IGHT-OF-WAY)
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)
1+00
2+00
3
+
0
0
1+002+00
STA: 1+04.85 STORM DRAIN 3
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 513.00
STA: 1+94.70 STORM DRAIN 4
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 513.00
STA: 1+03.05 STORM DRAIN 4-A
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 513.00
STA: 1+93.53 STORM DRAIN 4
INSTALL:
1 - 45° BEND
FL 10" IN: 512.91
FL 10" OUT: 512.91
STA: 1+91.65 STORM DRAIN 4
INSTALL:
1 - 45° BEND
FL 10" IN: 512.77
FL 10" OUT: 512.77
STA: 1+05.77 STORM DRAIN 1-D
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 512.00
STA: 3+03.36 STORM DRAIN 1
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 511.60
STA: 3+00.86 STORM DRAIN 1
INSTALL:
1 - 45° BEND
FL 10" IN: 511.55
FL 10" OUT: 511.55
STA: 2+97.32 STORM DRAIN 1
INSTALL:
1 - 45° BEND
FL 10" IN: 511.48
FL 10" OUT: 511.48
STA: 1+03.28 STORM DRAIN 1-D
INSTALL:
1 - 45° BEND
FL 10" IN: 511.34
FL 10" OUT: 511.34
STA: 1+01.88 STORM DRAIN 4-A
INSTALL:
1 - 45° BEND
FL 10" IN: 511.28
FL 10" OUT: 511.28
STA: 1+06.01 STORM DRAIN 1-C
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 511.00
STA: 2+67.98 STORM DRAIN 1
PIPE SIZE CHANGE
FL 10" IN: 510.90
FL 18" OUT: 510.23
STA: 2+62.98 STORM DRAIN 1
STA: 1+00.00 STORM DRAIN 1-D
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 510.13
FL 10" IN: 510.46
FL 18" OUT: 510.13
STA: 1+03.51 STORM DRAIN 1-C
INSTALL:
1 - 45° BEND
FL 10" IN: 510.32
FL 10" OUT: 510.32
STA: 1+06.01 STORM DRAIN 1-B
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 1+06.01 STORM DRAIN 1-A
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 2+51.45 STORM DRAIN 2
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 1+06.11 STORM DRAIN 2-C
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 1+06.11 STORM DRAIN 2-B
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 1+06.12 STORM DRAIN 2-A
END 10" PVC 5' FROM BLDG.
REF. MEP PLANS FOR
CONTINUATION.
FL 10" OUT: 510.00
STA: 2+48.95 STORM DRAIN 2
INSTALL:
1 - 45° BEND
FL 10" IN: 509.93
FL 10" OUT: 509.93
STA: 2+45.41 STORM DRAIN 2
INSTALL:
1 - 45° BEND
FL 10" IN: 509.83
FL 10" OUT: 509.83
STA: 2+07.56 STORM DRAIN 1
STA: 1+00.00 STORM DRAIN 1-C
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 509.02
FL 10" IN: 509.35
FL 18" OUT: 509.02
STA: 1+03.82 STORM DRAIN 2-C
INSTALL:
1 - 45° BEND
FL 10" IN: 509.41
FL 10" OUT: 509.41
STA: 1+03.51 STORM DRAIN 1-B
INSTALL:
1 - 45° BEND
FL 10" IN: 509.31
FL 10" OUT: 509.31
STA: 1+45.07 STORM DRAIN 4
PIPE SIZE CHANGE
FL 18" OUT: 508.57
STA: 1+03.51 STORM DRAIN 1-A
INSTALL:
1 - 45° BEND
FL 10" IN: 508.93
FL 10" OUT: 508.93
STA: 1+40.07 STORM DRAIN 4
STA: 1+00.00 STORM DRAIN 4-A
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 508.20
FL 10" IN: 508.53
FL 18" OUT: 508.20
STA: 1+03.82 STORM DRAIN 2-B
INSTALL:
1 - 45° BEND
FL 10" IN: 508.79
FL 10" OUT: 508.79
STA: 1+57.31 STORM DRAIN 1
STA: 1+00.00 STORM DRAIN 1-B
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 508.01
FL 10" IN: 508.34
FL 18" OUT: 508.01
STA: 1+95.54 STORM DRAIN 2
STA: 1+00.00 STORM DRAIN 2-C
INSTALL:
1 - 10" X 10" WYE
FL 10" IN: 508.42
FL 10" IN: 508.42
FL 10" OUT: 508.42
STA: 1+03.83 STORM DRAIN 2-A
INSTALL:
1 - 45° BEND
FL 10" IN: 508.35
FL 10" OUT: 508.35
STA: 1+11.84 STORM DRAIN 1
STA: 1+00.00 STORM DRAIN 1-A
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 507.10
FL 10" IN: 507.43
FL 18" OUT: 507.10
STA: 1+11.12 STORM DRAIN 1
INSTALL:
1 - 45° BEND
FL 18" IN: 507.08
FL 18" OUT: 507.08
STA: 1+54.71 STORM DRAIN 2
PIPE SIZE CHANGE
FL 10" IN: 507.26
FL 18" OUT: 506.59
STA: 1+49.71 STORM DRAIN 2
STA: 1+00.00 STORM DRAIN 2-B
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 506.45
FL 10" IN: 506.78
FL 18" OUT: 506.45
STA: 1+03.39 STORM DRAIN 4
INSTALL:
1 - 45° BEND
FL 18" IN: 505.42
FL 18" OUT: 505.42
STA: 1+07.68 STORM DRAIN 2
STA: 1+00.00 STORM DRAIN 2-A
INSTALL:
1 - 18" X 10" WYE
FL 18" IN: 505.26
FL 10" IN: 505.59
FL 18" OUT: 505.26
STA: 1+00.00 STORM DRAIN 4
CONNECT TO EXISTING
60". CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION PRIOR
TO CONSTRUCTION.
FL 18" IN: 505.16
STA: 1+03.85 STORM DRAIN 2
INSTALL:
1 - 45° BEND
FL 18" IN: 505.15
FL 18" OUT: 505.15
STA: 1+00.00 STORM DRAIN 2
CONNECT TO EXISTING
60". CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION PRIOR
TO CONSTRUCTION.
FL 18" IN: 505.04
STA: 1+00.00 STORM DRAIN 3
CONNECT TO EXISTING
60". CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION PRIOR
TO CONSTRUCTION.
FL 10" IN: 505.16
STA: 2+53.06 STORM LINE B
STA: 1+00.00 STORM DRAIN 1
INSTALL:
1 - 36" X 18" WYE
FL 18" IN: 506.86
FL 36" IN: 506.11
FL 36" OUT: 506.11 REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_ROOF DRAIN PLAN.dwg Jun 22, 2021-8:33am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C6.1ROOF DRAIN PLAN
STORM LINE A
490
495
500
505
510
515
520
525
530
490
495
500
505
510
515
520
525
530
0+50 1+00 2+00 3+00 4+00 5+00 6+00 6+50
STORM LINE A-1
495
500
505
510
515
520
525
530
535
495
500
505
510
515
520
525
530
535
0+50 1+00 1+50
STORM LINE A-2
495
500
505
510
515
520
525
530
535
495
500
505
510
515
520
525
530
535
0+50 1+00 2+00FL 60" (IN)=504.17FL 60" (OUT)=504.18FL 60" (IN)=504.18FL 18" (IN)=505.68DUAL 60" RCP @ 0.30%FL 60" (IN)=504.55FL 18" (IN)=506.05FL 60" (OUT)=504.55FL 60" (IN)=505.76FL 60" (OUT)=505.76FL 60" (OUT)=505.80FL 60" (IN)=504.94FL 60" (OUT)=504.9118" RCP @ 23.27%FL 18" (OUT)=514.83FL 60" (IN)=504.18FL 18" (IN)=505.68FL 60" (OUT)=504.1818" RCP @ 18.72%FL 18" (OUT)=516.14FL 60" (IN)=504.55FL 18" (IN)=506.05FL 60" (OUT)=504.55STA: 6+20.50 STORM LINE AINSTALL:2 - 50° BENDSTA: 6+33.31 STORM LINE ACONNECT TO EX. DUAL 60" RCPINSTALL:2 - 3' x 5' FORTERRA PRECASTJUNCTION BOX WITH RISER ANDMANHOLE FOR DUAL 60" RCP.STA: 3+47.60 STORM LINE AINSTALL:2 - 60° BENDSTA: 2+27.65 STORM LINE ASTA: 1+00.00 STORM LINE A-2INSTALL:1 - 60" X 18" WYESTA: 1+00.00 STORM LINE AINSTALL:1 - DOUBLE WINGEDHEADWALLSTA: 1+03.78 STORM LINE ASTA: 1+00.00 STORM LINE A-1INSTALL:1 - 60" X 18" WYEDUAL 60" RCP @ 0.30%18" RCP @ 23.27%STA: 1+39.32 STORM LINE A-1INSTALL:1 - 5' CURB INLETSTA: 1+03.78 STORM LINE ASTA: 1+00.00 STORM LINE A-1INSTALL:1 - 60" X 18" WYE18" RCP @ 18.72%STA: 1+53.89 STORM LINE A-2INSTALL:1 - 5' CURB INLETSTA: 2+27.65 STORM LINE ASTA: 1+00.00 STORM LINE A-2INSTALL:1 - 60" X 18" WYEFLOW
PARTIAL
FLOW
PARTIAL
Q100=3.12 cfs
Qcap=45.45 cfs
V100=1.76 fps
Sf=0.0009 ft/ft Q100=1.20 cfs
Qcap=50.67 cfs
V100=0.68 fps
Sf=0.0001 ft/ft
Q100=226.08 cfs
Qcap=285.30 cfs
V100=5.76 fps
Sf=0.0075 ft/ft
Q100=226.08 cfs
Qcap=285.30 cfs
V100=5.76 fps
Sf=0.0075 ft/ft
Q100=229.20 cfs
Qcap=285.30 cfs
V100=5.84 fps
Sf=0.0077 ft/ft
Q100=226.08 cfs
Qcap=285.30 cfs
V100=5.76 fps
Sf=0.0075 ft/ft
Q100=230.40 cfs
Qcap=285.30 cfs
V100=5.87 fps
Sf=0.0078 ft/ft
WATER CROSSING
STA:2+67.29
FL:517.00
6.81'PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
HGL
HGL
PROPOSED GRADE
CL OF PIPE
HGL
EXISTING GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
PROPOSED GRADE
CL OF PIPE
HGLHGL: 512.50HGL: 512.51HGL: 512.61HGL: 512.85HGL: 513.19HGL: 513.42HGL: 513.68HGL: 514.19HGL: 514.37HGL: 514.39HGL: 512.61HGL: 512.61HGL: 513.19HGL: 513.24STORM LINE B
495
500
505
510
515
520
525
530
535
495
500
505
510
515
520
525
530
535
0+50 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00FL 18" (IN)=511.81FL 18" (OUT)=511.81FL 18" (IN)=512.37FL 18" (OUT)=512.37FL 18" (IN)=513.04FL 18" (OUT)=513.04FL 18" (IN)=514.27FL 18" (OUT)=514.27FL 36" (IN)=504.96FL 36" (IN)=505.32FL 36" (OUT)=505.3236" RCP @ 0.75%FL 36" (IN)=506.46FL 24" (IN)=506.96FL 36" (OUT)=506.4618" RCP @
1
.
6
1
%FL 24" (IN)=508.74FL 18" (IN)=508.99FL 24" (OUT)=508.74FL 18" (OUT)=515.50STA: 5+39.15 STORM LINE BINSTALL:1 - 45° BENDSTA: 5+74.00 STORM LINE BINSTALL:1 - 45° BENDSTA: 6+15.71 STORM LINE BINSTALL:1 - 3' X 3' GRATE INLETSTA: 6+92.21 STORM LINE BINSTALL:1 - 3' X 3' GRATE INLETSTA: 1+00.00 STORM LINE BCONNECT TO EXISTING60". CONTRACTOR TOVERIFY HORIZONTAL ANDVERTICAL LOCATION PRIORTO CONSTRUCTION.STA: 1+48.36 STORM LINE BINSTALL:1 - 45° BENDPC36" RCP @ 0.75%STA: 3+00.44 STORM LINE BSTA: 1+00.00 STORM LINE B-1INSTALL:1 - 36" X 24" WYESTA: 3+79.80 STORM LINE BSTA: 1+00.00 STORM LINE B-2INSTALL:1 - 24" X 18" WYESTA: 7+68.71 STORM LINE BINSTALL:1 - 3' X 3' GRATE INLETSTA: 3+54.92 STORM LINE BPT Q100=5.43 cfs
Qcap=13.33 cfs
V100=3.08 fps
Sf=0.0027 ft/ft
Q100=6.13 cfs
Qcap=13.33 cfs
V100=3.47 fps
Sf=0.0034 ft/ft
Q100=8.92 cfs
Qcap=13.33 cfs
V100=5.05 fps
Sf=0.0072 ft/ft
Q100=8.92 cfs
Qcap=13.33 cfs
V100=5.05 fps
Sf=0.0072 ft/ft
Q100=10.52 cfs
Qcap=28.70 cfs
V100=3.35 fps
Sf=0.0022 ft/ft
Q100=29.54 cfs
Qcap=57.76 cfs
V100=4.18 fps
Sf=0.0020 ft/ft
Q100=29.54 cfs
Qcap=57.76 cfs
V100=4.18 fps
Sf=0.0020 ft/ft
WATER CROSSING
STA:1+34.01
FL:510.56
2.00'18" RCP @ 1
.
6
1
%
Q100=8.92 cfs
Qcap=13.33 cfs
V100=5.05 fps
Sf=0.0072 ft/ft
PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
FL 18" (IN)=506.86FL 36" (IN)=506.11FL 36" (OUT)=506.11 Q100=17.64 cfs
Qcap=57.76 cfs
V100=2.49 fps
Sf=0.0007 ft/ftSTA: 2+53.06 STORM LINE BSTA: 1+00.00 STORM DRAIN 1INSTALL:1 - 36" X 18" WYESTA: 3+05.44 STORM LINE BPIPE SIZE CHANGEFL 36" (OUT)=506.54FL 24" (IN)=507.54FL 24" (OUT)=508.82FL 18" (IN)=509.32STA: 3+84.80 STORM LINE BPIPE SIZE CHANGEFLOW
PARTIAL
HGL
HGLHGL: 512.50HGL: 512.59HGL: 512.73HGL: 512.93HGL: 513.17HGL: 513.20HGL: 513.30HGL: 513.48HGL: 513.74HGL: 514.88HGL: 515.08HGL: 515.33HGL: 515.47HGL: 515.77HGL: 515.91HGL: 516.16HGL: 516.28HGL: 516.3224" RCP @
1
.
6
1
%
STORM LINE B-1
490
495
500
505
510
515
520
525
530
490
495
500
505
510
515
520
525
530
0+50 1+00 1+50
24" R
C
P
@
4.
2
2
%FL 24" (OUT)=508.39FL 36" (IN)=506.46FL 24" (IN)=506.96FL 36" (OUT)=506.46STA: 1+33.83 STORM LINE B-1INSTALL:1 - 5' CURB INLETTC: 513.54STA: 3+00.44 STORM LINE BSTA: 1+00.00 STORM LINE B-1INSTALL:1 - 36" X 24" WYE Q100=7.11 cfs
Qcap=46.47 cfs
V100=2.26 fps
Sf=0.0010 ft/ft 2.00'WATER CROSSING
STA:1+11.53
FL:504.51
PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
HGL HGL: 513.30HGL: 513.34STORM LINE B-2
495
500
505
510
515
520
525
530
535
495
500
505
510
515
520
525
530
535
0+50 1+00 2+00
18" RCP
@
2
.
5
8
%FL 18" (OUT)=509.12FL 18" (IN)=509.12FL 18" (OUT)=510.23FL 24" (IN)=508.74FL 18" (IN)=508.99FL 24" (OUT)=508.74STA: 1+05.00 STORM LINE B-2INSTALL:1 - 45° BENDSTA: 1+48.17 STORM LINE B-2INSTALL:1 - 5' CURB INLETTC: 515.50STA: 3+79.80 STORM LINE BSTA: 1+00.00 STORM LINE B-2INSTALL:1 - 24" X 18" WYE Q100=1.60 cfs
Qcap=16.87 cfs
V100=0.90 fps
Sf=0.0002 ft/ft
WATER CROSSING
STA:1+10.67
FL:506.352.02' Q100=1.60 cfs
Qcap=16.87 cfs
V100=0.90 fps
Sf=0.0002 ft/ft
PROPOSED GRADE
CL OF PIPE
EXISTING GRADE
CL OF PIPE
HGL HGL: 513.74HGL: 513.74HGL: 513.84HGL: 513.85REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_STORM PROFILES.dwg Jun 22, 2021-8:33am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C6.2STORM PROFILES1:4 V
1:40 H
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_STORM CALCULATIONS.dwg Jun 22, 2021-8:33am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C6.3STORM CALCULATIONSCURB INLET CALCULATIONS
WYE INLET CALCULATIONS
DUAL285.30
285.30
285.30
285.30
285.30
DUAL
DUAL
DUAL
DUAL
226.08
226.08
226.08
229.20
230.40
LEGEND
PROPERTY LINE
EXISTING SANITARY SEWER AND MANHOLE
EXISTING WATER AND FIRE HYDRANT
SS PROPOSED SANITARY SEWER
W PROPOSED WATER
PROPOSED STORM LINE
EASEMENT LINE
EXISTING STORM LINE
SS
W W
EXISTING GAS LINEGAS
EXISTING OVERHEAD ELECTRICOHE
PROPOSED GATE VALVE
FIRE DEPARTMENT CONNECTION
PROPOSED FIRE HYDRANT ASSEMBLY
PROPOSED MANHOLE
PROPOSED DOMESTIC METER
PROPOSED IRRIGATION METER
PROPOSED GRATE INLET
PROPOSED WYE INLET
EXISTING UNDERGROUND ELECTRICUGE
PROPOSED GAS LINEGAS
PROPOSED CURB INLET
POWER POLE
UTILITY NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN.
2.REFER TO MEP AND ARCHITECTURAL PLANS FOR CONNECTION TO
DOWNSPOUTS AT BUILDINGS AND FLOWLINES.
3.CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING FLOWLINE
ELEVATIONS DO NOT MATCH THOSE SHOWN ON THE PLAN.
4.CONTRACTOR TO ADJUST MANHOLE RIM ELEVATIONS TO MATCH
FINISH GRADE.
5.CONTRACTOR TO REMOVE SILT AND DEBRIS FROM END OF EXISTING
STORM SEWER PRIOR TO MAKING CONNECTION.
6.REFER TO CITY OF COPPELL CONSTRUCTION DETAILS AND
SPECIFICATIONS.
7.ALL UTILITY STUBS SHOWN SHALL BE PLUGGED 5' PAST PROPOSED
PAVEMENT EDGE OR 5' OUTSIDE THE BUILDING.
8.REFER TO TCEQ DESIGN GUIDELINES FOR ALL UTILITY CROSSINGS.
9.A 5-FOOT CLEARANCE SHALL BE MAINTAINED AROUND ALL FIRE
HYDRANTS.
10.FIRE SPRINKLER LINE SHALL BE SIZED AND INSTALLED BY A STATE
LICENSED FIRE SPRINKLER CONTRACTOR.
11.ALL WATER METERS SHALL BE LOCATED IN LANDSCAPE AREAS.
12.WATER TO HAVE A MINIMUM 4' OF COVER.
15' T.X.U. ELECTRIC
COMPANY EASEMENT
(VOL. 99172, PG. 16)
D.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
10' SANITARY SEWER
EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.VANNO PARKINGNO PARKINGNO PARKING
TWWW
WWWWWWWWWWWW W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W WWWWWWWWWWSSSSSSSSSSSSSSSSGASGASGASGASGASGASW
W
W W W
W W W WWWW W SS7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54
'
2
3
"
W
1
0
4
.
9
8
'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'S 37°11'03" E 15.40'
LP
LP
LP
LP
LP
LP
IRR. WM
WM
1
2
EXISTING
HEADWALL
PROPOSED
HEADWALL
EXISTING
60" RCP
EX. STORM
EX. STORMEX. STORM
EX. STORM
EXISTING
60" RCP
PROPOSED
TRANSFORMER1+002+003+004+005+006+00 7+00 8+00
9+00
10+00
11+00 12+0013+0014+0015+0015+37PC: 7+70.34
PT: 9+97.71
FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT
W
IDE
R
IGHT-OF-WAY
)
(
A
L
S
O
K
N
OW
N
A
S
L
Y
N
D
O
N
B
.
J
O
H
N
S
O
N
F
R
E
EW
A
Y
)
(
V
A
R
I
A
B
L
E
W
I
D
T
H
R
I
G
H
T
-
O
F
-W
A
Y
)
I
N
T
E
R
S
T
A
T
E
H
I
G
HW
A
Y
6
3
5
1+00
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
PROPOSED
GAS METER
PROPOSED GAS
LINE
1+00
2+00 3+00 4+00 5+00 5+76
±55 LF OF BORE
UNDER FRITZ
DRIVE
!!!CAUTION!!!
WATER AND STORM
CROSSING PER TCEQ
STANDARDS
±75 LF OF BORE
UNDER FRITZ
DRIVE
±65 LF OF BORE
UNDER FRITZ
DRIVE
FDC (REF. CITY OF
COPPELL STD.
DTL. 4170)
8 "W A T E R L I N E A
8" WATER LINE A8" WATER LINE A8" WATER LINE A8" WA
T
E
R
L
I
N
E
A
WATER LINE A STA: 1+00
CONNECT TO EXISTING 12"
WATER. CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION.
INSTALL:
1 - 12" X 8" TAPPING
SLEEVE AND VALVE
WATER LINE A STA: 15+37.42
CONNECT TO EXISTING 12"
WATER. CONTRACTOR TO
VERIFY HORIZONTAL AND
VERTICAL LOCATION.
INSTALL:
1 - 12" X 8" TAPPING
SLEEVE AND VALVE
WATER LINE A STA: 14+49.63
INSTALL:
1 - DOUBLE DETECTOR
CHECK VALVE. REF.
CITY OF COPPELL
STD. DTL. 4165
WATER LINE A STA: 1+79.58
INSTALL:
1 - 2" DOMESTIC SERVICE
1 - 2" DOMESTIC METER
2 - 45° BENDS
REF. CITY OF COPPELL
STD. DTL. 4150
±139 LF OF 2" SERVICE. END 5'
FROM BLDG. REF. MEP PLANS FOR
CONTINUATION.
WATER LINE A STA: 2+07.18
INSTALL:
1 - 8" X 8" TEE
2 - 8" GATE VALVE
±137 LF OF 8" FIRE
SERVICE
END 8" FIRE SERVICE 5'
FROM BLDG. REF. MEP
PLANS FOR CONTINUATION.
WATER LINE A STA: 2+15.11
INSTALL:
1 - 8" X 6" TEE
1 - 8" GATE VALVE
1 - FH ASSEMBLY
REF. CITY OF COPPELL
STD. DTL. 4120 (TYP.)
WATER LINE A STA: 2+26.80
INSTALL:
1 - 45° BEND
WATER LINE A STA: 2+78.68
INSTALL:
1 - 45° BEND
WATER LINE A STA: 4+68.42
INSTALL:
1 - 8" X 6" TEE
1 - 8" GATE VALVE
1 - FH ASSEMBLY
REF. CITY OF COPPELL
STD. DTL. 4120 (TYP.)
WATER LINE A STA: 5+42.75
INSTALL:
1 - 45° BEND
WATER LINE A STA: 5+71.27
INSTALL:
1 - 45° BEND
WATER LINE A STA: 7+53.45
INSTALL:
1 - 8" X 6" TEE
1 - 8" GATE VALVE
1 - FH ASSEMBLY
REF. CITY OF COPPELL
STD. DTL. 4120 (TYP.)
WATER LINE A STA: 10+38.55
INSTALL:
1 - 8" X 6" TEE
1 - 8" GATE VALVE
1 - FH ASSEMBLY
REF. CITY OF COPPELL
STD. DTL. 4120 (TYP.)
WATER LINE A STA: 11+83.08
INSTALL:
1 - 22.5° BEND
WATER LINE A STA: 12+48.65
INSTALL:
1 - 45° BEND
WATER LINE A STA: 13+32.71
INSTALL:
1 - 8" X 6" TEE
1 - 8" GATE VALVE
1 - FH ASSEMBLY
REF. CITY OF COPPELL
STD. DTL. 4120 (TYP.)
STA: 1+90.61 SEWER LINE A
STA: 1+00.00 SEWER LINE A-1
INSTALL:
1 - 4' DIA MH
REF. CITY OF COPPELL
STD. DTL. 5020 OR 5030
RIM: 524.00
FL 8" (IN) (E): 515.85
FL 8" (IN) (S): 515.85
FL 8" (OUT) (W): 515.65
SEWER LINE A-1 STA: 1+04.37
END 8" SEWER WITH CLEANOUT
5' FROM BLDG. REF. MEP
PLANS FOR CONTINUATION
FL 8" (OUT) (N): 516.00
SEWER LINE A STA: 5+76.09
END 8" SEWER WITH CLEANOUT
5' FROM BLDG. REF. MEP
PLANS FOR CONTINUATION
FL 8" (OUT) (W): 519.32
WATER LINE A STA: 1+87.42
INSTALL:
1 - 2" IRRIGATION METER
1 - 2" IRRIGATION PD METER
WITH BACKFLOW PREVENTION
REF. CITY OF COPPELL STD. DTL. 4155
WATER LINE A STA: 1+98.68
INSTALL:
1 - 8" DOUBLE DETECTOR
CHECK VALVE. REF.
CITY OF COPPELL
STD. DTL. 4165
SEWER LINE A STA: 1+00
CONNECT TO EXISTING
4' DIA MH. ADJUST TO FINISH
GRADE. CONTRACTOR TO
FIELD VERIFY HORIZONTAL
AND VERTICAL LOCATION PRIOR
TO CONSTRUCTION.
FL 8" (OUT) (N): 514.70
FL 8" (IN) (E): 514.80
8" SEWER @ 0.94%8" SEWER @ 0.90%
8" SEWER @ 3.43%
WATER METER SCHEDULE
SIZE NO.TYPEID NO.
IRRIGATION (PD METER)
2"
1
2
1
1
PROPOSED
PROPOSED
2"
DOMESTIC (PD METER)
C7.0UTILITY PLANREVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_UTILITY PLAN.dwg Jun 22, 2021-8:34am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST
OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A
FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN.
NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40
BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45'
WEST OF A POWER POLE
NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65
BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150'
WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST
OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN.
NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33
BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY,
±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM
MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL.
NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25
BENCH MARK LIST
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
!!WARNING!!
EXISTING UNDERGROUND UTILITIES. CONTRACTOR
SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES
AND COORDINATE WITH CORRESPONDING COMPANY
PRIOR TO CONSTRUCTION.
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
SEWER LINE A
500
505
510
515
520
525
530
535
540
500
505
510
515
520
525
530
535
540
0+50 1+00 2+00 3+00 4+00 5+00 6+00
8" SDR-35 @ 0.90%FL 8" (OUT)=519.328" SDR-35 @ 0.90%FL 8" (IN)=515.85FL 8" (IN)=515.85FL 8" (OUT)=515.65STA: 5+76.09 SEWER LINE AEND 8" SEWER WITH CLEANOUT5' FROM BLDG. REF. MEPPLANS FOR CONTINUATIONRIM: 520.05STA: 1+90.61 SEWER LINE AINSTALL:1 - 4' DIA MHREF. CITY OF COPPELLSTD. DTL. 5020 OR 5030RIM: 524.008" SDR-35 @ 0.90%
EXISTING GRADE
CL OF PIPE
PROPOSED GRADE
CL OF PIPE
FL 8" (IN)=514.80FL EX 6" (IN)=514.80FL EX 8" (OUT)=514.708" SDR-35 @ 0.94%STA: 1+00.00 SEWER LINE ACONNECT TO EXISTING4' DIA MH. ADJUST TO FINISHGRADE. CONTRACTOR TOFIELD VERIFY HORIZONTALAND VERTICAL LOCATION PRIORTO CONSTRUCTION.RIM: 523.00SEWER LINE A-1
500
505
510
515
520
525
530
535
540
500
505
510
515
520
525
530
535
540
0+50 1+00 1+50
8" SDR-35 @ 3.43%FL 8" (OUT)=516.00FL 8" W(OUT)=515.65FL 8"E(IN)=515.85FL 8"S(IN)=515.85STA: 1+04.37 SEWER LINE A-1END 8" SEWER WITH CLEANOUT5' FROM BLDG. REF. MEPPLANS FOR CONTINUATIONRIM: 516.73STA: 1+90.61 SEWER LINE AINSTALL:1 - 4' DIA MHREF. CITY OF COPPELLSTD. DTL. 5020 OR 5030RIM: 524.00EXISTING GRADE
CL OF PIPE
PROPOSED GRADE
CL OF PIPE
REVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2021
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SFLP HOLDINGSLOT 3R, BLOCK A!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
JTH
JUNE 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_UTILITY PROFILES.dwg Jun 22, 2021-8:34am mnietoBGE, INC.NATERRA INTERNATIONALNKH
1250 S. FREEPORT PKWY.
SFPLP HOLDINGS MANAGMENT LLC
COPPELL, TEXAS 75019
OWNER/DEVELOPER
Contact: Jin Song
Tel: 817-403-0303
ARCHITECT
5310 HARVEST HILL RD., SUITE 180
PROSS DESIGN GROUP INC.
DALLAS, TX 75230
Contact: Mark Pross
Tel: 972-759-1400
BGE, Inc.
F-1046
C7.1UTILITY PROFILES1:4 V
1:40 H
C8.0CITY OF COPPELL CONSTRUCTION
DETAILSREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:34am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:34am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400C8.1CITY OF COPPELL CONSTRUCTION
DETAILS
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:34am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046C8.2CITY OF COPPELL CONSTRUCTION
DETAILS
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:34am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046C8.3CITY OF COPPELL CONSTRUCTION
DETAILS
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:34am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046C8.4CITY OF COPPELL CONSTRUCTION
DETAILS
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2021CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SFLP HOLDINGS
LOT 3R, BLOCK A!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesJTHJUNE 2021CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:8499-00G:\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_CITY STANDARD DETAILS.dwg Jun 22, 2021-8:35am mnietoBGE, INC.
NATERRA INTERNATIONAL
NKH1250 S. FREEPORT PKWY.SFPLP HOLDINGS MANAGMENT LLCCOPPELL, TEXAS 75019OWNER/DEVELOPERContact: Jin SongTel: 817-403-0303ARCHITECT5310 HARVEST HILL RD., SUITE 180PROSS DESIGN GROUP INC.DALLAS, TX 75230Contact: Mark ProssTel: 972-759-1400BGE, Inc.F-1046C8.5CONSTRUCTION DETAILS
138 s.f.
24,059 s.f.
14,665 s.f.
160 s.f.
141 s.f.
141 s.f.
305 s.f.
160 s.f.1,196 s.f.
109 s.f.
141 s.f.302 s.f.
161 s.f.
9.989 s.f.
309 s.f.
592 s.f.
116 s.f.
586 s.f.
157 s.f.
107 s.f.
166 s.f.
131 s.f.
148 s.f.
117 s.f.156 s.f.
253 s.f.
955 s.f.
843 s.f.
287 s.f.
158 s.f.
50 s.f.
681 s.f.
127 s.f.
199 s.f.
184 s.f.
429 s.f.
14,636 s.f.
1,241 s.f.
23 s.f.
310 s.f.
54 s.f.
2,939 s.f.
2,093 s.f.
136 s.f.
146 s.f.
3,219 s.f.
3,825 s.f.VANNO PARKINGNO PARKINGNO PARKING
12
12
12
11 11
8 9
14
14
12 12
4
7
8
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
T
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
10' SANITARY SEWER
EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
40' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.515520 511
511512513514516517518519515
512
513
514
516
517
518
519 519520
521
522
523 5215
2
2
520
5205205205
2
6
52
7
52
8
529
52052552152252352452652
0
5
2
1
510515 507508509511512513514516517518519
520
525
519
521522523524
526
510
515
520
509511512513514516517518519521522525530524526527528529531532533525524526527528529 5
0
6
5075
0
6
507
508
509
505506507 519517523522523522521520521522519519519519521520519518518
517
516
515
514
513
5165155145135125115115
1
0 512L0.00
LANDSCAPE AREA PLAN
N 0 15 30 60
SCALE: 1" = 30'-0"
TOTAL SITE AREA: 321,659 S.F.
NET SITE AREA: 186,422 S.F.
TOTAL LANDSCAPE AREA: 87,015 S.F. (27%)
REQUIRED PROVIDED
PERIMETER LANDSCAPE 24,745 S.F.
INTERIOR LANDSCAPE 2,422 S.F. (10%)3,827 S.F. (16%)
OPEN SPACE 27,963 S.F. (15%)58,468 S.F. (31%)
LANDSCAPE AREA LEGEND
INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
VANNO PARKINGNO PARKINGNO PARKING
12
12
12
11 11
8 9
14
14
12 12
4
7
8
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
LOT 1R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.LOT 1R, BLOCK 1
IAAM HEADQUARTERS
(INST. NO. 202000153484)
O.P.R.D.C.T.
FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)TRACT 1
SFPLP HOLDINGS MANAGEMENT, LLC
(INST. NO. 201200031715)
O.P.R.D.C.T.
SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
T
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
10' SANITARY SEWER
EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
40' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.515520 511
511512513514516517518519515
512
513
514
516
517
518
519 519520
521
522
523 5215
2
2
520
5205205205
2
6
52
7
52
8
529
52052552152252352452652
0
5
2
1
510515 507508509511512513514516517518519
520
525
519
521522523524
526
510
515
520
509511512513514516517518519521522525530524526527528529531532533525524526527528529 5
0
6
5075
0
6
507
508
509
505506507 519517523522523522521520521522519519519519521520519518518
517
516
515
514
513
5165155145135125115115
1
0 5121
2
3
4
5
6
7 1
8
9
10
11
12 13
14
15 16
17
18
20 22
23
24
25 26
27
28
29
30
31
32
19 XX
X
X
X
XXXX
X
X
XXXX XXXXXXXXEXISTING TREE
TO REMAIN, TYP.
EXISTING TREE
TO REMAIN, TYP.
TREE PROTECTION FENCING TO
REMAIN DURING CONSTRUCTION, TYP.
REFER TO 01/L1.02
TREE PROTECTION FENCING TO
REMAIN DURING CONSTRUCTION, TYP.
REFER TO 01/L1.02
EXISTING TREE TO BE
REMOVED, TYP.
EXISTING TREE TO BE
REMOVED, TYP.
EXISTING TREE
TO REMAIN, TYP.INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
L1.01
TREE PRESERVATION PLAN
N 0 15 30 60
SCALE: 1" = 30'-0"
X
EXISTING TREE
TO BE REMOVED
TREE PROTECTION FENCING
TO REMAIN DURING CONSTRUCTION
REFER TO 01/L1.02
EXISTING TREE
TO REMAIN
EXISTING TREE LEGEND
TREE PRESERVATION NOTES
1.EXISTING TREES TO REMAIN SHALL BE PROTECTED
DURING CONSTRUCTION FROM TREE STRUCTURE
DAMAGE AND COMPACTION OF SOIL UNDER AND
AROUND DRIP LINE (CANOPY) OF TREE.
2.IF ANY ROOT STRUCTURE IS DAMAGED DURING
ADJACENT EXCAVATION / CONSTRUCTION, NOTIFY
OWNER'S AUTHORIZED REPRESENTATIVE
IMMEDIATELY. IT IS RECOMMENDED THAT A LICENSED
ARBORIST BE SECURED FOR THE TREATMENT OF ANY
POSSIBLE TREE WOUNDS.
3.NO DISTURBANCE OF THE SOIL GREATER THAN 4"
SHALL BE LOCATED CLOSER TO THE TREE TRUNK
THAN 1/2 THE DISTANCE OF THE DRIP LINE TO THE
TREE TRUNK. A MINIMUM OF 75% OF THE DRIP LINE
AND ROOT ZONE SHALL BE PRESERVED AT NATURAL
GRADE.
4.ANY FINE GRADING DONE WITHIN THE CRITICAL ROOT
ZONES OF THE PROTECTED TREES MUST BE DONE
WITH LIGHT MACHINERY SUCH AS A BOBCAT OR
LIGHT TRACTOR. NO EARTH MOVING EQUIPMENT
WITH TRACKS IS ALLOWED WITHIN THE CRITICAL
ROOT ZONE OF THE TREES.
5.NO MATERIALS INTENDED FOR USE IN CONSTRUCTION
OR WASTE MATERIALS ACCUMULATED DUE TO
EXCAVATION OR DEMOLITION SHALL BE PLACED
WITHIN THE LIMITS OF THE DRIP LINE OF ANY TREE.
6.NO EQUIPMENT MAY BE CLEANED OR TOXIC
SOLUTIONS, OR OTHER LIQUID CHEMICALS, SHALL BE
DEPOSITED WITHIN THE LIMITS OF THE DRIP LINE OF A
TREE, INCLUDING BUT NOT LIMITED TO: PAINT, OIL,
SOLVENTS, ASPHALT, CONCRETE, MORTAR, PRIMERS,
ETC.
7.NO SIGNS, WIRES OR OTHER ATTACHMENTS, OTHER
THAN THOSE OF A PROTECTIVE NATURE, SHALL BE
ATTACHED TO ANY TREE.
8.NO VEHICULAR / CONSTRUCTION EQUIPMENT TRAFFIC
OR PARKING IS ALLOWED WITHIN THE LIMITS OF THE
DRIP LINE OF TREES.
9.BORING OF UTILITIES MAY BE PERMITTED UNDER
PROTECTED TREES IN CERTAIN CIRCUMSTANCES. THE
MINIMUM LENGTH OF THE BORE SHALL BE THE WIDTH
OF THE TREE'S CANOPY AND SHALL BE A MINIMUM
DEPTH OF FORTY-EIGHT (48") INCHES.
10.IRRIGATION TRENCHING WHICH MUST BE DONE WITHIN
THE CRITICAL ROOT ZONE OF A TREE SHALL BE DUG
BY HAND AND ENTER THE AREA IN A RADIAL MANNER.
11.ALL TREES TO BE REMOVED FROM THE SITE SHALL BE
FLAGGED BY THE CONTRACTOR WITH BRIGHT RED
VINYL TAPE (3" WIDTH) WRAPPED AROUND THE MAIN
TRUNK AT A HEIGHT OF FOUR (4') FEET ABOVE GRADE.
FLAGGING SHALL BE APPROVED BY OWNER'S
AUTHORIZED REPRESENTATIVE PRIOR TO ANY TREE
REMOVAL. CONTRACTOR SHALL CONTACT OWNER'S
AUTHORIZED REPRESENTATIVE WITH 72 HOURS
NOTICE TO SCHEDULE ON-SITE MEETING.
12.ALL TREES TO REMAIN, AS NOTED ON DRAWINGS,
SHALL HAVE PROTECTIVE FENCING LOCATED AT THE
TREE'S DRIP LINE. THE PROTECTIVE FENCING MAY BE
COMPRISED OF SNOW FENCING, ORANGE VINYL
CONSTRUCTION FENCING, CHAIN LINK FENCE OR
OTHER SIMILAR FENCING WITH A FOUR (4') FOOT
APPROXIMATE HEIGHT. THE PROTECTIVE FENCING
SHALL BE LOCATED AS INDICATED ON THE TREE
PROTECTION DETAIL.
13.WHEN A LOW HANGING LIMB IS BROKEN DURING THE
COURSE OF CONSTRUCTION, THE CONTRACTOR SHALL
NOTIFY THE OWNER'S AUTHORIZED REPRESENTATIVE
IMMEDIATELY. UNDER NO CIRCUMSTANCE SHALL THE
CONTRACTOR PRUNE ANY PORTION OF THE DAMAGED
TREE WITHOUT THE PRIOR APPROVAL BY THE
OWNER'S AUTHORIZED REPRESENTATIVE.4'-0" MIN.3'-0"LIMITS OF DRIPLINE
01TREE PROTECTIVE FENCING
NOT TO SCALE
REFER TO PLAN FOR
EXISTING TREE TO REMAIN
EXISTING GRADE TO
REMAIN UNDISTURBED
METAL T-POST PLACED NO
FURTHER THAN 8' APART
SNOW FENCE, ORANGE VINYL
CONSTRUCTION FENCE, OR
CHAINLINK FENCE
INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
L1.01
TREE PRESERVATION NOTES
TREE MITIGATION TABULATIONS
CITY OF COPPELL, TEXAS
LESS THAN 12"
GROSS RETRIBUTION 82.5 cal. in.
minus (-)
PRESERVATION CREDIT:
Trees Preserved on Site 211.5 cal. in.
divided by (÷)
Total Trees on Site 376.5 cal. in.
equals (=)
Preservation Percentage 56%
times (x)
Gross Retribution 82.5 cal. in.
equals (=)
PRESERVATION CREDIT 46.2 cal. in.
minus (-)
LANDSCAPE CREDIT -48 cal. in.
equals (=)
48 trees, 4" cal.
48*1 = 48
NET RETRIBUTION 0 times (x)
$100.00x $100.00
equals (=)
CONTRIBUTION TO CITY OF $0.00
COPPELL REFORESTATION
AND NATURAL AREAS FUND
TREE MITIGATION TABULATIONS
CITY OF COPPELL, TEXAS
12" OR GREATER
GROSS RETRIBUTION 85.5 cal. in.
minus (-)
PRESERVATION CREDIT:
Trees Preserved on Site 211.5 cal. in.
divided by (÷)
Total Trees on Site 376.5 cal. in.
equals (=)
Preservation Percentage 56%
times (x)
Gross Retribution 85.5 cal. in.
equals (=)
PRESERVATION CREDIT 47.88 cal. in.
minus (-)
LANDSCAPE CREDIT -48 cal. in.
equals (=)
12 trees, 4" cal.
12*1 = 12
9 trees, 4" cal.
9*4 = 36
NET RETRIBUTION 0
times (x) $200.00x $200.00
equals (=)
CONTRIBUTION TO CITY OF $0.00
COPPELL REFORESTATION
AND NATURAL AREAS FUND
TOTAL COMBINED
CONTRIBUTION TO CITY OF $0.00
COPPELL REFORESTATION
AND NATURAL AREAS FUND
VANNO PARKINGNO PARKINGNO PARKING
12
12
12
11 11
8 9
14
14
12 12
4
7
8
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.10' BUILDING & PARKINGSETBACK(VOL. 99172, PG. 16)D.R.D.C.T.FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
S 56°
3
8'
0
6"
W
1
6
4.
3
9'
S 68°2
3'
1
1
"
W
1
6
0
.
8
7'
S 69°2
6'
2
2
"
W
7
8
.
8
7'
S 70°4
2'
3
1
"
W
5
6
.
4
9'
S 73°54'
2
3
"
W
1
0
4
.
9
8
'
S 75°29'
3
8
"
W
1
9
9
.
7
5
'S 37°25'01" W 60.69'
S 64°
3
3'
2
0
"
W
9
5.
8
1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'
S 00°39'34" W 13.76'
N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60'S 37°11'03" E 15.40'
T
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
DRAINAGE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
10' SANITARY SEWER
EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
WATER LINE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
20' HIKE AND BIKE
TRAIL EASEMENT
(VOL. 98043, PG. 1)
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
10' UTILITY EASEMENT
(VOL. 82137, PG. 690)
D.R.D.C.T.
SIDEWALK EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
T.P. & L. EASEMENT
(VOL. 71159, PG. 743)
D.R.D.C.T.
EXISTING 10' DRAINAGE
EASEMENT
24' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.
40' FIRE LANE EASEMENT
(INST. NO. 201700240374)
O.P.R.D.C.T.515520 511
511512513514516517518519515
512
513
514
516
517
518
519 519520
521
522
523 5215
2
2
520
5205205205
2
6
52
7
52
8
529
52052552152252352452652
0
5
2
1
510515 507508509511512513514516517518519
520
525
519
521522523524
526
510
515
520
509511512513514516517518519521522525530524526527528529531532533525524526527528529 5
0
6
5075
0
6
507
508
509
505506507 519517523522523522521520521522519519519519521520519518518
517
516
515
514
513
5165155145135125115115
1
0 5121
2
3
4
5
6
7 1
8
9
10
11
14
22
26
31
32
19
EXISTING TREE
TO REMAIN, TYP.
EXISTING TREE
TO REMAIN, TYP.
EXISTING TREE
TO REMAIN, TYP.
12
TS
3
SO
1
CP
1
CP
3
CP
2
SO
46
TS
3
SO
3
LO
1
CP
1
CP
1
CP
1
CP
1
LO
1
SO
1
CP
3
LO
1
CP
3
SO
1
LO
24" MULCH BED
, TYP. AT B.O.C.
UTILITY GRAVEL,4" DEPTH
WITH WEED BARRIER FABRIC, TYP.
LAWN HYDROMULCH
BERMUDAGRASS, TYP.
LAWN HYDROMULCH
BERMUDAGRASS, TYP.
LAWN HYDROMULCH
BERMUDAGRASS, TYP.
4
CO
4
CO
4
SO
2
CO
2
CP
12
CP
1
CP
LAWN SOLID SOD
BERMUDAGRASS, TYP.
LAWN SOLID SOD
BERMUDAGRASS, TYP.
UTILITY GRAVEL,4" DEPTH
WITH WEED BARRIER FABRIC, TYP.
24" MULCH BED,
TYP. AT B.O.C.
sidewalk connections
changed
1
CO
1
CP
INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
L2.01
LANDSCAPE PLAN
N 0 15 30 60
SCALE: 1" = 30'-0"
Planning Administrative
Approval
06/23/2021
INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
L2.02
LANDSCAPE NOTES
LANDSCAPE NOTES
1.CONTRACTOR SHALL VERIFY ALL EXISTING AND
PROPOSED SITE ELEMENTS AND NOTIFY LANDSCAPE
ARCHITECT OF ANY DISCREPANCIES. SURVEY DATA
OF EXISTING CONDITIONS WAS SUPPLIED BY OTHERS.
2.CONTRACTOR SHALL LOCATE ALL EXISTING
UNDERGROUND UTILITIES AND NOTIFY LANDSCAPE
ARCHITECT OF ANY CONFLICTS. CONTRACTOR SHALL
EXERCISE CAUTION WHEN WORKING IN THE VICINITY
OF UNDERGROUND UTILITIES.
3.CONTRACTOR SHALL PROVIDE A MINIMUM 2% SLOPE
AWAY FROM ALL STRUCTURES.
4.CONTRACTOR SHALL FINE GRADE AREAS TO ACHIEVE
FINAL CONTOURS AS INDICATED. LEAVE AREAS TO
RECEIVE TOPSOIL 3" BELOW FINAL FINISHED GRADE IN
PLANTING AREAS AND 1" BELOW FINAL FINISHED
GRADE IN LAWN AREAS.
5.ALL PLANTING BEDS AND LAWN AREAS SHALL BE
SEPARATED BY STEEL EDGING. NO STEEL EDGING
SHALL BE INSTALLED ADJACENT TO BUILDINGS,
WALKS, OR CURBS. CUT STEEL EDGING AT 45 DEGREE
ANGLE WHERE IT INTERSECTS WALKS AND CURBS.
6.TOP OF MULCH SHALL BE 1/2" MINIMUM BELOW THE
TOP OF WALKS AND CURBS.
7.ALL LAWN AREAS SHALL BE HYDROMULCH
BERMUDAGRASS, UNLESS OTHERWISE NOTED ON THE
DRAWINGS.
8.ALL REQUIRED LANDSCAPE AREAS SHALL BE
PROVIDED WITH AN AUTOMATIC UNDERGROUND
IRRIGATION SYSTEM WITH RAIN AND FREEZE SENSORS
AND EVAPOTRANSPIRATION (ET) WEATHER-BASED
CONTROLLERS AND SAID IRRIGATION SYSTEM SHALL
BE DESIGNED BY A QUALIFIED PROFESSIONAL AND
INSTALLED BY A LICENSED IRRIGATOR.
9.CONTRACTOR SHALL PROVIDE BID PROPOSAL LISTING
UNIT PRICES FOR ALL MATERIAL PROVIDED.
10.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING
ALL REQUIRED LANDSCAPE AND IRRIGATION PERMITS.
MAINTENANCE NOTES
1.THE OWNER, TENANT AND THEIR AGENT, IF ANY,
SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR
THE MAINTENANCE OF ALL LANDSCAPE.
2.ALL LANDSCAPE SHALL BE MAINTAINED IN A NEAT
AND ORDERLY MANNER AT ALL TIMES. THIS SHALL
INCLUDE MOWING, EDGING, PRUNING, FERTILIZING,
WATERING, WEEDING AND OTHER SUCH ACTIVITIES
COMMON TO LANDSCAPE MAINTENANCE.
3.ALL LANDSCAPE AREAS SHALL BE KEPT FREE OF
TRASH, LITTER, WEEDS AND OTHER SUCH MATERIAL
OR PLANTS NOT PART OF THIS PLAN.
4.ALL PLANT MATERIAL SHALL BE MAINTAINED IN A
HEALTHY AND GROWING CONDITION AS IS
APPROPRIATE FOR THE SEASON OF THE YEAR.
5.ALL PLANT MATERIAL WHICH DIES SHALL BE
REPLACED WITH PLANT MATERIAL OF EQUAL OR
BETTER VALUE.
6.CONTRACTOR SHALL PROVIDE SEPARATE BID
PROPOSAL FOR ONE YEAR'S MAINTENANCE TO BEGIN
AFTER FINAL ACCEPTANCE.
GENERAL LAWN NOTES
1.CONTRACTOR SHALL COORDINATE OPERATIONS AND
AVAILABILITY OF EXISTING TOPSOIL WITH ON-SITE
CONSTRUCTION MANAGER.
2.CONTRACTOR SHALL LEAVE LAWN AREAS 1" BELOW
FINAL FINISHED GRADE PRIOR TO TOPSOIL
INSTALLATION.
3.CONTRACTOR SHALL FINE GRADE AREAS TO ACHIEVE
FINAL CONTOURS AS INDICATED ON CIVIL PLANS.
ADJUST CONTOURS TO ACHIEVE POSITIVE DRAINAGE
AWAY FROM BUILDINGS. PROVIDE UNIFORM
ROUNDING AT TOP AND BOTTOM OF SLOPES AND
OTHER BREAKS IN GRADE. CORRECT IRREGULARITIES
AND AREAS WHERE WATER MAY STAND.
4.ALL LAWN AREAS SHALL BE FINE GRADED, IRRIGATION
TRENCHES COMPLETELY SETTLED AND FINISH GRADE
APPROVED BY THE OWNER'S CONSTRUCTION
MANAGER OR LANDSCAPE ARCHITECT PRIOR TO LAWN
INSTALLATION.
5.CONTRACTOR SHALL REMOVE ALL ROCKS 3/4"
DIAMETER AND LARGER, DIRT CLODS, STICKS,
CONCRETE SPOILS, ETC. PRIOR TO PLACING TOPSOIL
AND LAWN INSTALLATION.
6.CONTRACTOR SHALL MAINTAIN ALL LAWN AREAS
UNTIL FINAL ACCEPTANCE. THIS SHALL INCLUDE, BUT
NOT BE LIMITED TO: MOWING, WATERING, WEEDING,
CULTIVATING, CLEANING AND REPLACING DEAD OR
BARE AREAS TO KEEP PLANTS IN A VIGOROUS,
HEALTHY CONDITION.
7.CONTRACTOR SHALL GUARANTEE ESTABLISHMENT OF
ACCEPTABLE TURF AREA AND SHALL PROVIDE
REPLACEMENT FROM LOCAL SUPPLY IF NECESSARY.
SOLID SOD NOTES (ALTERNATE BID)
1.PLANT SOD BY HAND TO COVER INDICATED AREAS
COMPLETELY. ENSURE EDGES OF SOD ARE TOUCHING.
TOP DRESS JOINTS BY HAND WITH TOPSOIL TO FILL
VOIDS.
2.ROLL GRASS AREAS TO ACHIEVE A SMOOTH, EVEN
SURFACE, FREE FROM UNNATURAL UNDULATIONS.
3.WATER SOD THOROUGHLY AS SOD OPERATION
PROGRESSES.
4.IF INSTALLATION OCCURS BETWEEN SEPTEMBER 1
AND MARCH 1, OVER-SEED BERMUDAGRASS SOD
WITH WINTER RYEGRASS, AT A RATE OF FOUR (4)
POUNDS PER ONE THOUSAND (1000) SQUARE FEET.
HYDROMULCH NOTES (BASE BID)
1.CONTRACTOR SHALL SCARIFY, RIP AND LOOSEN ALL
AREAS TO BE HYDROMULCHED TO A MINIMUM DEPTH
OF 4" PRIOR TO TOPSOIL AND HYDROMULCH
INSTALLATION.
2.BERMUDAGRASS SEED SHALL BE EXTRA HULLED AND
TREATED LAWN TYPE, SHALL BE DELIVERED TO THE
SITE IN ITS ORIGINAL UNOPENED CONTAINER AND
SHALL MEET STATE LAW REQUIREMENTS.
3.FIBER SHALL BE ONE HUNDRED PERCENT (100%)
WOOD CELLULOSE FIBER, DELIVERED TO THE SITE IN
ITS ORIGINAL UNOPENED CONTAINER AS
MANUFACTURED BY 'CONWEB' OR EQUAL.
4.FIBER TACK SHALL BE DELIVERED TO THE SITE IN ITS
ORIGINAL UNOPENED CONTAINER AND SHALL BE
'TERRO-TACK ONE', AS MANUFACTURED BY
GROWERS, INC. OR EQUAL.
5.HYDROMULCH WITH BERMUDAGRASS SEED AT A RATE
OF TWO (2) POUNDS PER ONE THOUSAND (1000)
SQUARE FEET.
6.USE A 4'X8' BATTER BOARD AGAINST ALL BED AREAS.
7.IF INSTALLATION OCCURS BETWEEN SEPTEMBER 1
AND MAY 1, ALL HYDROMULCH AREAS TO BE WINTER
RYEGRASS, AT A RATE OF FOUR (4) POUNDS PER ONE
THOUSAND (1000) SQUARE FEET. CONTRACTOR
SHALL BE REQUIRED TO RE-HYDROMULCH WITH
BERMUDAGRASS THE FOLLOWING GROWING SEASON
AS PART OF THIS CONTRACT.
8.ALL LAWN AREAS TO BE HYDROMULCHED SHALL
HAVE ONE HUNDRED PERCENT (100%) COVERAGE
PRIOR TO FINAL ACCEPTANCE.
9.NOTE: PROVIDE ALTERNATE BID WITH UNIT PRICING
FOR ALL LAWN AREAS WITH HYDROMULCH
BERMUDAGRASS TO BE SOLID SOD BERMUDAGRASS.
LANDSCAPE TABULATIONS
CITY OF COPPELL, TEXAS
PERIMETER LANDSCAPE
1.Street Frontage: 15' landscape buffer with one (1) tree,
3" cal., per 50 l.f.
2.Perimeter Landscape: 10' landscape buffer along property
lines with one (1) tree, 3" cal., per 50 l.f.
3.30" ht. parking lot screen: hedge or berm.
FRITZ DRIVE: 763 l.f.
Required Provided
15' landscape buffer 15' landscape buffer
(15) trees, 3" cal.(15) trees, 4" cal.*
30" ht. screen 30" ht. evergreen hedge
FREEPORT PARKWAY: 213 l.f.
Required Provided
15' landscape buffer 15' landscape buffer
(4) trees, 3" cal.(4) trees, 4" cal.*
30" ht. parking screen 30" ht. evergreen hedge
SOUTH PROPERTY LINE: 922 l.f.
Required Provided
10' landscape buffer 10' landscape buffer
(18) trees, 3" cal.(13) existing trees, 3"+ cal.
(6) trees, 4" cal.*
WEST PROPERTY LINE: 576 l.f.
Required Provided
10' landscape buffer 10' landscape buffer
(12) trees, 3" cal.(4) existing trees, 3"+ cal.
(8) trees, 4" cal.*
INTERIOR LANDSCAPE
1.10% of gross parking area to be landscape.
2.One (1) tree per 400 s.f. of required landscape area.
3.12% of total number parking spaces shall be planting
islands with trees.
Parking Lot: 24,217 s.f.
Parking Spaces: 146
Required Provided
2,422 (10%)3,827 s.f. (16%)
(6) trees (18) trees, 4" cal.*
(18) parking islands (22) parking islands
OPEN SPACE
1.Requirements: 15% of lot not covered by buildings to be
landscape open space.
2.50% of open space shall be in the front yard.
3.One (1) tree per 2500 s.f. of open space.
Total Lot Area (Exclusive of building): 186,422 s.f.
Required Provided
27,963 s.f. (15%)58,443 (31%)
13,982 s.f. (50%)14,807 s.f. (53%)
(10) trees (11) trees, 4" cal.*
SUMMARY
Required Provided
(65) trees (17) existing trees, 3"+ cal.
(60) trees, 4" cal.*
* additional 1" to be counted towards mitigation
INTERNATIONAL INC.SURVV GHVLJQ JURXS, LQFRUSRUDWHG5310 HDUYHVW HLOO RRDG, SXLWH 180, DDOODV, TH[DV 75230. 972759-1400STA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT422 6KORINH
A
UGA N
06/21/21
L2.03
LANDSCAPE SPECIFICATIONS
AND DETAILS
PREPARED SOIL MIX PER
SPECIFICATIONS; TILL 6" MINIMUM
OF PREPARED SOIL MIX INTO
6" DEPTH OF EXISTING SOIL
3/16" X 4" BLACK EDGING,
STAKES ON INSIDE; EDGING SHALL
BE 1/2" MAXIMUM HEIGHT
ABOVE FINISH GRADE
TOP OF MULCH 1/2"
MINIMUM BELOW TOP OF
CONCRETE WALK / CURB
CONCRETE WALK LAWN / FINISH GRADE
NOTE:
NO STEEL EDGING SHALL
BE INSTALLED ALONG
SIDEWALKS OR CURBS
ROOTBALL,
DO NOT DISTURB
NATIVE SOIL
POCKET PLANTING
NOT ALLOWED
SHRUBS / GROUNDCOVER;
REFER TO LANDSCAPE PLAN
TOPDRESS MULCH PER
SPECIFICATIONS; 2" MINIMUM
SETTLED THICKNESS
SCARIFY SIDES
REFER TO LANDSCAPE PLAN
FOR SPACING6"
A.
E.
C.B.
I.
H.
F.
G.
D.
TREE PLANTING DETAIL LEGEND
AND NOTES
A.TREE: TREES SHALL CONFORM WITH
LATEST AMERICAN STANDARD FOR
NURSERY STOCK. www.anla.org
B.TREE PIT: WIDTH TO BE AT LEAST TWO
(2) TIMES THE DIAMETER OF THE ROOT
BALL CENTER TREE IN HOLE & REST
ROOT BALL ON UNDISTURBED NATIVE
SOIL.
C.ROOT BALL: REMOVE TOP 13 BURLAP
AND ANY OTHER FOREIGN OBJECT;
CONTAINER GROWN STOCK TO BE
INSPECTED FOR GIRDLING ROOTS.
D.ROOT FLARE: ENSURE THAT ROOT
FLARE IS EXPOSED, FREE FROM MULCH,
AND AT LEAST TWO INCHES ABOVE
GRADE. TREES SHALL BE REJECTED
WHEN GIRDLING ROOTS ARE PRESENT &
ROOT FLARE IS NOT APPARENT.
E.ROOTBALL ANCHOR RING: REFER TO
MANUFACTURER'S GUIDELINES FOR
SIZING. PLACE ROOTBALL ANCHOR
RING ON BASE OF ROOTBALL, TRUNK
SHOULD BE IN THE CENTER OF THE
RING.
F.ROOT ANCHOR BY TREE STAKE
SOLUTIONS.
G.NAIL STAKE: REFER TO
MANUFACTURER'S GUIDELINES FOR
SIZING. INSTALL NAIL STAKES WITH
HAMMER OR MALLET FIRMLY INTO
UNDISTURBED GROUND. DRIVE NAIL
STAKES FLUSH WITH "U" BRACKET
ADJACENT TO ROOTBALL (DO NOT
DISTURB ROOTBALL).
H.BACKFILL: USE EXISTING NATIVE SOIL
(no amendments) WATER THOROUGHLY
TO ELIMINATE AIR POCKETS.
I.MULCH: DOUBLE SHREDDED
HARDWOOD MULCH 2 INCH SETTLED
THICKNESS, WITH 2" HT. WATERING
RING; ENSURE THAT ROOT FLARE IS
EXPOSED. BELOW GROUND STAKE
SHOULD NOT BE VISIBLE.
J.TREE STAKES:
TREE STAKE SOLUTIONS 'SAFETY
STAKE' BELOW GROUND MODEL
AVAILABLE FROM:
Tree Stake Solutions
ATTN: Jeff Tuley
(903) 676-6143
jeff@treestakesolutions.com
www.treestakesolutions.com
OR APPROVED EQUAL. TREES SHALL BE
STAKED BELOW GROUND WHERE
NECESSARY; ABOVE GROUND STAKING
IS EXPRESSLY PROHIBITED.
K.IT SHALL BE THE RESPONSIBILITY OF
THE CONTRACTOR TO OBTAIN A COPY
OF THE MANUFACTURER'S
SPECIFICATIONS PRIOR TO
INSTALLATION OF TREE STAKES.
CONTRACTOR SHALL ADHERE TO
MANUFACTURER'S INSTALLATION
GUIDELINES, SPECIFICATIONS, AND
OTHER REQUIREMENTS FOR TREE STAKE
INSTALLATION.
01TREE PLANTING DETAIL
NOT TO SCALE 02SHRUB / GROUNDCOVER DETAIL
NOT TO SCALE
SECTION 32 9300 - LANDSCAPE
PART 1 - GENERAL
1.1 REFERENCED DOCUMENTS
A.Refer to Landscape Plans, notes, details, bidding requirements,
special provisions, and schedules for additional requirements.
1.2 DESCRIPTION OF WORK
A.Work included: Furnish all supervision, labor, materials, services,
equipment and appliances required to complete the work covered
in conjunction with the landscaping covered in these
specifications and landscaping plans, including:
1. Planting (trees, shrubs and grasses)
2. Bed preparation and fertilization
3. Notification of sources
4. Water and maintenance until final acceptance
5. Guarantee
1.3 REFERENCE STANDARDS
A.American Standard for Nursery Stock published by American
Association of Nurserymen: April 14, 2014 Edition; by American
National Standards Institute, Inc. (Z60.1) – plant material
B.American Joint Committee on Horticultural Nomenclature: 1942
Edition of Standardized Plant Names.
C.Texas Association of Nurserymen, Grades and Standards
D.Hortis Third, 1976 - Cornell University
1.4 NOTIFICATION OF SOURCES AND SUBMITTALS
A.Samples: Provide representative quantities of sandy loam soil,
mulch, bed mix material, gravel, crushed stone, steel edging and
tree stakes. Samples shall be approved by Owner's Authorized
Representative before use on the project.
1.5 JOB CONDITIONS
A.General Contractor to complete the following punch list: Prior to
Landscape Contractor initiating any portion of landscape
installation, General Contractor shall leave planting bed areas
three (3") inches below final finish grade of sidewalks, drives and
curbs as shown on the drawings. All lawn areas to receive solid
sod shall be left one (1") inch below the final finish grade of
sidewalks, drives and curbs. All construction debris shall be
removed prior to Landscape Contractor beginning any work.
B.Storage of materials and equipment at the job site will be at the
risk of the Landscape Contractor. The Owner cannot be held
responsible for theft or damage.
1.6 MAINTENANCE AND GUARANTEE
A.Maintenance:
1.The Landscape Contractor shall be held responsible for the
maintenance of all work from the time of planting until final
acceptance by the Owner. No trees, shrubs, groundcover or
grass will be accepted unless they show healthy growth and
satisfactory foliage conditions.
2.Maintenance shall include watering of trees and plants,
cultivation, weeding spraying, edging, pruning of trees,
mowing of grass, cleaning up and all other work necessary
of maintenance.
3.A written notice requesting final inspection and acceptance
should be submitted to the Owner at least seven (7) days
prior to completion. An on-site inspection by the Owner's
Authorized Representative will be completed prior to written
acceptance.
B.Guarantee:
1.Trees, shrubs and groundcover shall be guaranteed for a
twelve (12) month period after final acceptance. The
Contractor shall replace all dead materials as soon as
weather permits and upon notification of the Owner. Plants,
including trees, which have partially died so that shape, size,
or symmetry have been damaged, shall be considered
subject to replacement. In such cases, the opinion of the
Owner shall be final.
a.Plants used for replacement shall be of the same size
and kind as those originally planted and shall be planted
as originally specified. All work, including materials,
labor and equipment used in replacements, shall carry a
twelve (12) month guarantee. Any damage, including
ruts in lawn or bed areas, incurred as a result of making
replacements shall be immediately repaired.
b.At the direction of the Owner, plants may be replaced
at the start of the next year's planting season. In such
cases, dead plants shall be removed from the premises
immediately.
c.When plant replacements are made, plants, soil mix,
fertilizer and mulch are to be utilized as originally
specified and re-inspected for full compliance with the
contract requirements. All replacements are to be
included under "Work" of this section.
2.The Owner agrees that for the guarantee to be effective, he
will water plants at least twice a week during dry periods
and cultivate beds once a month after final acceptance.
3.The above guarantee shall not apply where plants die after
acceptance because of injury from storms, hail, freeze,
insects, diseases, injury by humans, machines or theft.
4.Acceptance for all landscape work shall be given after final
inspection by the Owner provided the job is in a complete,
undamaged condition and there is a stand of grass in all
lawn areas. At that time, the Owner will assume
maintenance on the accepted work.
C.Repairs: Any necessary repairs under the Guarantee must be
made within ten (10) days after receiving notice, weather
permitting. In the event the Landscape Contractor does not
make repairs accordingly, the Owner, without further notice to
Contractor, may provide materials and men to make such repairs
at the expense to the Landscape Contractor.
1.7 QUALITY ASSURANCE
A.General: Comply with applicable federal, state, county and local
regulations governing landscape materials and work.
B.Personnel: Employ only experienced personnel who are familiar
with the required work. Provide full time supervision by a
qualified foreman acceptable to Landscape Architect.
C.Selection of Plant Material:
1.Make contact with suppliers immediately upon obtaining
notice of contract acceptance to select and book materials.
Develop a program of maintenance (pruning and fertilization)
which will ensure the purchased materials will meet and / or
exceed project specifications.
2.Substitutions: Do not make plant material substitutions. If
the specified landscape material is not obtainable, submit
proof of non-availability to Landscape Architect, together
with proposal for use of equivalent material. At the time
bids are submitted, the Contractor is assumed to have
located the materials necessary to complete the job as
specified.
3.Landscape Architect will provide a key identifying each tree
location on site. Written verification will be required to
document material selection, source and delivery schedules
to site.
4.Measurements: Measure trees with branches and trunks or
canes in their normal position. Do not prune to obtain
required sizes. Take caliper measurements six inches above
ground for trees up to and including 4" caliper size, and
twelve inches above ground for larger sizes. Measure main
body of all plant material of height and spread dimensions,
do not measure from branch or root tip-to-tip.
5.Owner's Authorized Representative shall inspect all plant
material with requirements for genus, species, cultivar /
variety size and quality.
6.Owner's Authorized Representative retains the right to
further inspect all plant material upon arrival to the site and
during installation for size and condition of root balls and
root systems, limbs, branching habit, insects, injuries and
latent defects.
7.Owner's Authorized Representative may reject
unsatisfactory or defective material at any time during the
process work. Remove rejected materials immediately from
the site and replace with acceptable material at no additional
cost to the Owner. Plants damaged in transit or at job site
shall be rejected.
1.8 PRODUCT DELIVERY, STORAGE AND HANDLING
A.Preparation:
1.Balled and Burlapped (B&B) Plants: Dig and prepare
shipment in a manner that will not damage roots, branches,
shape and future development.
2.Container Grown Plants: Deliver plants in rigid container to
hold ball shape and protect root mass.
B.Delivery:
1.Deliver packaged materials in sealed containers showing
weight, analysis and name of manufacturer. Protect
materials from deterioration during delivery and while stored
on site.
2.Deliver only plant materials that can be planted in one day
unless adequate storage and watering facilities are available
on job site.
3.Protect root balls by heeling in with sawdust or other
approved moisture retaining material if not planted within 24
hours of delivery.
4.Protect plants during delivery to prevent damage to root
balls or desiccation of leaves. Keep plants moist at all
times. Cover all materials during transport.
5.Notify Owner's Authorized Representative of delivery
schedule 72 hours in advance job site.
6.Remove rejected plant material immediately from job site.
7.To avoid damage or stress, do not lift, move, adjust to
plumb, or otherwise manipulate plants by trunk or stems.
PART 2 - PRODUCTS
2.1 PLANTS
A.General: Well-formed No. 1 grade or better nursery grown stock.
Listed plant heights are from tops of root balls to nominal tops of
plants. Plant spread refers to nominal outer width of the plant,
not to the outer leaf tips. Plants will be individually approved by
the Owner's Authorized Representative and his decision as to
their acceptability shall be final.
B.Quantities: The drawings and specifications are complementary.
Anything called for on one and not the other is as binding as if
shown and called for on both. The plant schedule is an aid to
bidders only. Confirm all quantities on plan.
C.Quality and size: Plant materials shall conform to the size given
on the plan, and shall be healthy, symmetrical, well-shaped, full
branched and well rooted. The plants shall be free from injurious
insects, diseases, injuries to the bark or roots, broken branches,
objectionable disfigurements, insect eggs and larvae, and are to
be of specimen quality.
D.Approval: All plants which are found unsuitable in growth, or are
in any unhealthy, badly shaped or undersized condition will be
rejected by the Owner's Authorized Representative either before
or after planting and shall be removed at the expense of the
Landscape Contractor and replaced with acceptable plant as
specified at no additional cost to the Owner.
E.Trees shall be healthy, full-branched, well-shaped, and shall meet
the minimum trunk and diameter requirements of the plant
schedule. Balls shall be firm, neat, slightly tapered and well
wrapped in burlap. Any tree loose in the ball or with a broken
root ball at time of planting will be rejected. Balls shall be ten
(10") inches in diameter for each one (1") inch of trunk diameter,
measured six (6") inches above ball. (Nomenclature confirms to
the customary nursery usage. For clarification, the term
"multi-trunk" defines a plant having three (3) or more trunks of
nearly equal diameter.)
F.Pruning: All pruning of trees and shrubs, as directed by the
Landscape Architect prior to final acceptance, shall be executed
by the Landscape Contractor at no additional cost to the Owner.
2.2 SOIL PREPARATION MATERIALS
A.Sandy Loam:
1.Friable, fertile, dark, loamy soil, free of clay lumps, subsoil,
stones and other extraneous material and reasonably free of
weeds and foreign grasses. Loam containing Dallasgrass or
Nutgrass shall be rejected.
2.Physical properties as follows:
a.Clay – between 7-27 percent
b.Silt – between 15-25 percent
c.Sand – less than 52 percent
3.Organic matter shall be 3%-10% of total dry weight.
4.If requested, Landscape Contractor shall provide a certified
soil analysis conducted by an approved soil testing
laboratory verifying that sandy loam meets the above
requirements.
B.Organic Material: Compost with a mixture of 80% vegetative
matter and 20% animal waste. Ingredients should be a mix of
course and fine textured material.
C.Premixed Bedding Soil as supplied by Vital Earth Resources,
Gladewater, Texas; Professional Bedding Soil as supplied by
Living Earth Technology, Dallas, Texas or Acid Gro Municipal Mix
as supplied by Soil Building Systems, Dallas, Texas or approved
equal.
D.Sharp Sand: Sharp sand must be free of seeds, soil particles and
weeds.
E.Mulch: Double Shredded Hardwood Mulch, partially decomposed,
dark brown. Living Earth Technologies or approved equal.
F.Organic Fertilizer: Fertilaid, Sustane, or Green Sense or equal as
recommended for required applications. Fertilizer shall be
delivered to the site in original unopened containers, each
bearing the manufacturer's guaranteed statement of analysis.
G.Commercial Fertilizer: 10-20-10 or similar analysis. Nitrogen
source to be a minimum 50% slow release organic Nitrogen
(SCU or UF) with a minimum 8% sulfur and 4% iron, plus
micronutrients.
H.Peat: Commercial sphagnum peat moss or partially decomposed
shredded pine bark or other approved organic material.
2.3 MISCELLANEOUS MATERIALS
A.Steel Edging: All steel edging shall be 3/16" thick x 4" deep x
16' long with 6 stakes per section, painted black at the factory
as manufactured by The J.D. Russell Company and under its
trade name DURAEDGE Heavy Duty Steel.
B.Staking Material for Shade Trees: refer to details.
C.Gravel: Washed native pea gravel, graded 1 inch to 1-1/2 inch.
D.Filter Fabric: 'Mirafi Mirascape' by Mirafi Construction Products
available at Lone Star Products, Inc., (469) 523-0444 or
approved equal.
E.River Rock: 'Colorado' or native river rock, 2" - 4" dia.
F.Decomposed Granite: Base material shall consist of a natural
material mix of granite aggregate not to exceed 1/8" diameter in
size and shall be composed of various stages of decomposed
earth base.
PART 3 - EXECUTION
3.1 BED PREPARATION & FERTILIZATION
A.Landscape Contractor to inspect all existing conditions and
report any deficiencies to the Owner.
B.All planting areas shall be conditioned as follows:
1.Prepare new planting beds by scraping away existing grass
and weeds as necessary. Till existing soil to a depth of six
(6") inches prior to placing compost and fertilizer. Apply
fertilizer as per Manufacturer's recommendations. Add six
(6") inches of compost and till into a depth of six (6") inches
of the topsoil. Apply organic fertilizer such as Sustane or
Green Sense at the rate of twenty (20) pounds per one
thousand (1,000) square feet.
2.All planting areas shall receive a two (2") inch layer of
specified mulch.
3.Backfill for tree pits shall be as follows: Use existing top soil
on site (use imported topsoil as needed) free from large
clumps, rocks, debris, caliche, subsoils, etc., placed in nine
(9") inch layers and watered in thoroughly.
C.Grass Areas:
1.Blocks of sod should be laid joint to joint (staggered joints)
after fertilizing the ground first. Roll grass areas to achieve
a smooth, even surface. The joints between the blocks of
sod should be filled with topsoil where they are evidently
gaped open, then watered thoroughly.
3.2 INSTALLATION
A.Maintenance of plant materials shall begin immediately after each
plant is delivered to the site and shall continue until all
construction has been satisfactorily accomplished.
B.Plant materials shall be delivered to the site only after the beds
are prepared and areas are ready for planting. All shipments of
nursery materials shall be thoroughly protected from the drying
winds during transit. All plants which cannot be planted at once,
after delivery to the site, shall be well protected against the
possibility of drying by wind and Balls of earth of B & B plants
shall be kept covered with soil or other acceptable material. All
plants remain the property of the Contractor until final
acceptance.
C.Position the trees and shrubs in their intended location as per
plan.
D.Notify the Owner's Authorized Representative for inspection and
approval of all positioning of plant materials.
E.Excavate pits with vertical sides and horizontal bottom. Tree
pits shall be large enough to permit handling and planting
without injury to balls of earth or roots and shall be of such
depth that,when planted and settled, the crown of the plant shall
bear the same relationship to the finish grade as it did to soil
surface in original place of growth.
F.Shrub and tree pits shall be no less than twenty-four (24")
inches wider than the lateral dimension of the earth ball and six
(6") inches deeper than it's vertical dimension. Remove and haul
from site all rocks and stones over three-quarter (3 4") inch in
diameter. Plants should be thoroughly moist before removing
containers.
G.Dig a wide, rough sided hole exactly the same depth as the
height of the ball, especially at the surface of the ground. The
sides of the hole should be rough and jagged, never slick or
glazed.
H.Percolation Test: Fill the hole with water. If the water level does
not percolate within 24 hours, the tree needs to move to another
location or have drainage added. Install a PVC stand pipe per
tree planting detail as approved by the Landscape Architect if the
percolation test fails.
I.Backfill only with 5 parts existing soil or sandy loam and 1 part
bed preparation. When the hole is dug in solid rock, topsoil from
the same area should not be used. Carefully settle by watering
to prevent air pockets. Remove the burlap from the top 13 of the
ball, as well as all nylon, plastic string and wire. Container trees
will usually be root bound, if so follow standard nursery practice
of ‘root scoring’.
J.Do not wrap trees.
K.Do not over prune.
L.Mulch the top of the ball. Do not plant grass all the way to the
trunk of the tree. Leave the area above the top of the ball and
mulch with at least two (2") inches of specified mulch.
M.All plant beds and trees to be mulched with a minimum settled
thickness of two (2") inches over the entire bed or pit.
N.Obstruction below ground: In the event that rock, or
underground construction work or obstructions are encountered
in any plant pit excavation work to be done under this section,
alternate locations may be selected by the Owner. Where
locations cannot be changed, the obstructions shall be removed
to a depth of not less than three (3') feet below grade and no
less than six (6") inches below the bottom of ball when plant is
properly set at the required grade. The work of this section shall
include the removal from the site of such rock or underground
obstructions encountered at the cost of the Landscape
Contractor.
O.Trees and large shrubs shall be staked as site conditions require.
Position stakes to secure trees against seasonal prevailing winds.
P.Pruning and Mulching: Pruning shall be directed by the
Landscape Architect and shall be pruned in accordance with
standard horticultural practice following Fine Pruning, Class I
pruning standards provided by the National Arborist Association.
1.Dead wood, suckers, broken and badly bruised branches
shall be removed. General tipping of the branches is not
permitted. Do not cut terminal branches.
2.Pruning shall be done with clean, sharp tools.
3.Immediately after planting operations are completed, all tree
pits shall be covered with a layer of organic material two
(2") inches in depth. This limit of the organic material for
trees shall be the diameter of the plant pit.
Q.Steel Curbing Installation:
1.Curbing shall be aligned as indicated on plans. Stake out
limits of steel curbing and obtain Owners approval prior to
installation.
2.All steel curbing shall be free of kinks and abrupt bends.
3.Top of curbing shall be 12" maximum height above final
finished grade.
4.Stakes are to be installed on the planting bed side of the
curbing, as opposed to the grass side.
5.Do not install steel edging along sidewalks or curbs.
6.Cut steel edging at 45 degree angle where edging meets
sidewalks or curbs.
3.3 CLEANUP AND ACCEPTANCE
A.Cleanup: During the work, the premises shall be kept neat and
orderly at all times. Storage areas for all materials shall be so
organized so that they, too, are neat and orderly. All trash and
debris shall be removed from the site as work progresses. Keep
paved areas clean by sweeping or hosing them at end of each
work day.
END OF SECTION
VANNO PARKINGNO PARKINGNO PARKING
7.384 Acres
321,659 Square Feet
LOT 3R, BLOCK A
GATEWAY BUSINESS PARK NO. 2
(INST. NO. 201700240374)
O.P.R.D.C.T.
FRITZ DRIVE
(FORMERLY KNOWN AS COTTON ROAD)
(57.50-FOOT WIDE RIGHT-OF-WAY)FREEPORT PARKWAY(80-FOOT WIDE RIGHT-OF-WAY)SFPLP HOLDINGS
MANAGEMENT, LLC
(INST. NO. 201200037650)
O.P.R.D.C.T.
T
(2) 4" SLEEVES
(2) 4" SLEEVES
(2) 4" SLEEVES
ESP-50LXD WALLMOUNT CONTROLLER
(LOCATE IN ELECTRICAL ROOM)
(110 VOLT POWER BY GENERAL CONTRACTOR)
WITH WR2 RAIN/FREEZE SENSOR BY LIC
(2) 4" SLEEVES
64.0
2" V
21
50.0
2" V
25
39.0
1-1/2"V
26
64.0
2" V
1
48.0
2" V
4
64.0
2" V
5
63.0
2" V
7
53.8
2" V
13
58.0
2" V
15
60.0
2" V
17
52.0
2" V
18
27.0
1" V
23
40.0
2" V
20
31.0
1-1/2"V
19
40.0
2" V
16
60.0
2" V
11
62.0
2" V
9
52.0
2" V
6
10's 10's 10's 10's
12's
15's
15's
10's
18's
8's
10's
10's
8's
8's
8's
15's
18's
15's
8's
8's
8's
15's15's
15's
8's
18's
18's
12's
15's
15's
18's
8's
8's
18's
18's
12's 10's
1.50
1" DV
22
1.10
1" DV
8
2.60
1" DV
10
14.0
1" V
24
1" V
13.0
1" V
3
1" V
19.0
1" V
12
1" V
16.0
1" V
14
1" V
4" SLEEVE
4" SLEEVE
4" SLEEVE
15's
8's
10's
15's
4" SLEEVE
(2) 4" SLEEVES
18's
15's
10's
8's
15's
15's 4" SLEEVE15's
8's
1/2"
1/2"
1/2"
1/2"
1/2"1/2"
3/4"
1/2"
3/4"3/4"
3/4"
3/4"
3/4"
3/4"
3/4"3/4"
3/4"
3/4"
3/4"
3/4"
1"1"1-1/4"1-1/4"
2"
3/4"
2-1/2"
3/4"
3/4"
3/4"
3/4"
1-1/4"
1-1/4"
1-1/4"
3/4"
2"
1/2"1/2"3/4"
3/4"
3/4"
1"
1-1/4"
1-1/4"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
1"
1-1/4"
1-1/4"
3/4"
1/2"
1/2"
1/2"
3/4"
3/4"
1"
1-1/4"
1/2"
3/4"
1/2"
1/2"
1/2"
3/4"
1-1/4"
1-1/4"
1-1/4"1-1/2"
1/2"3/4"3/4"
1/2"1/2"
1/2"1/2"3/4"
3/4"3/4"
3/4"1"1"
1"1"
1-1/4"
1-1/4"
3/4"3/4"
3/4"3/4"
3/4"
3/4"3/4"
3/4"1"
1"
1/2"
1/2"
1/2"
1/2"3/4"
3/4"
3/4"
3/4"1"
1"1"
1"1-1/4"
1-1/4"1-1/4"
1-1/4"1/2"1/2"
1/2"1/2"
3/4"
3/4"3/4"
3/4"1"
1"1"
1"1-1/4"
1-1/4"1-1/4"
2-1/2"
2-1/2"
3/4"3/4"
3/4"3/4"3/4"
3/4"3/4"
3/4"
1"
1"1"
1"1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1/2"1/2"
1/2"1/2"
1/2"
3/4"
1-1/4"
1-1/4"
1-1/4"
1/2"
1/2"
3/4"
1/2"1/2"
3/4"1"
1/2"
1/2"
3/4"
3/4"
1"
1"
1/2"
1/2"1/2"3/4"
3/4"
1"
1"
1-1/4"
1-1/4"
2"
1/2"
1/2"
1/2"
3/4"
1/2"
1/2"
1/2"
1/2"
3/4"3/4"
3/4"3/4"
1-1/4"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
1"
1"
1-1/4"1-1/4"
1/2"
1/2"
3/4"1/2"
1/2"1/2"
3/4"
1/2"
1-1/4"
1-1/4"
1/2"
1/2"3/4"
3/4"3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1-1/4"
1-1/4"1/2"1/2"3/4"3/4"
1/2"1/2"
3/4"
1"
1"
1"1-1/4"1-1/4"
1/2"1/2"
3/4"1"
3/4"
3/4"
3/4"
3/4"
1"
1-1/4"
1-1/4"
3/4"
3/4"
1"
1"
1-1/4"
1-1/4"3/4"
3/4"
3/4"
3/4"
1"
1"
1-1/4"
1-1/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1-1/4"
1-1/4"
3/4"
3/4"3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1-1/4"
1-1/2"
3/4"
3/4"
3/4"
1-1/4"
1/2"
1/2"
3/4"
3/4"
1"
1-1/4"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
1-1/4"
1-1/4"1/2"3/4"
1/2"1/2"
3/4"
1/2"
1/2"
3/4"
3/4"
1/2"
1/2"
3/4"
1-1/4"
1/2"1/2"1/2"1/2"3/4"3/4"
1"
1/2"
1/2"
3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
3/4"
1/2"
1/2"
3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
1/2"
1"
1"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1-1/4"
1"
1/2"
1/2"
1/2"
3/4"
3/4"
1"
W
2" TAP & SERVICE, IMPACT
FEES, & METER BOX BY GC
2" WYE STRAINER BY LIC
2" WATER METER BY GC
2" DOUBLE CHECK ASSY BY LIC
2" MASTER VALVE BY LIC
2" ISOLATION VALVE BY LIC
1-1/4"
1-1/4"
32.0
1-1/2"V
2
1"
1"
3/4"3/4"
3/4"
3/4"
1-1/4"
1-1/4"
1"
1"
1/2"
5Q
4" SLEEVE
4" SLEEVE
INTERNATIONAL INC.pross design group, incorporated5310 Harvest Hill Road, Suite 180, Dallas, Texas 75230. 972/759-140006/21/21
Irrigation in Texas is regulated by the Texas Commission of Environmental
Quality (TCEQ), MC-178, P.O. Box 13087, Austin, Texas, 78711-3087.
TCEQ website is: www.tceq.state.tx.us
L3.01
IRRIGATION PLAN
N 0 15 30 60
SCALE: 1" = 30'-0"
INTERNATIONAL INC.pross design group, incorporated5310 Harvest Hill Road, Suite 180, Dallas, Texas 75230. 972/759-140006/21/21
Irrigation in Texas is regulated by the Texas Commission of Environmental
Quality (TCEQ), MC-178, P.O. Box 13087, Austin, Texas, 78711-3087.
TCEQ website is: www.tceq.state.tx.us
L3.02
IRRIGATION DETAILS
BALL VALVE
10" RAINBIRD VB VALVE BOX W/
PURPLE LID, SET 1/4" ABOVE
FINISH GRADE
HANDLE
BALL VALVE
S X MPT PVC ADAPTER
WALLMOUNT CONTROLLER
NOTES:
1. REFER TO MANUFACTURER'S MANUAL
FOR MOUNTING INSTRUCTIONS
2. INSTALL WIRING (PER LOCAL CODE)
3. INSTALL CONDUIT W/ SWEEP FITTINGS
AND PULL WIRE
CONTROLLER
JUNCTION BOX
2" PVC CONDUIT FOR VALVE WIRING
120 VOLT WIRE CONDUIT PER
LOCAL CODE
EXTENSIONS AS REQ'D
FINISH GRADE
TYPE "K" COPPER FROM WATER METER,
45 DEGREE ELL TO REQUIRED DEPTH
CLASS 200 PVC, 45 DEGREE
(KEEP TEST COCKS CLEAR
PER LOCAL CODE)
DOUBLE CHECK ASSEMBLY
ELL TO REQ. DEPTH
VALVE BOX (PER LOCAL CODE) SET
DOUBLE-CHECK ASSEMBLY
1/4" ABOVE FINISH GRADE
18" OR 24"
WIRING
INTERVALS.
1. TAPE & BUNDLE WIRING AT 10'-0"
TRENCHING DETAIL
PVC MAINLINE
12"
MAINLINE, LATERAL, AND WIRING
SPEC.
REF
PVC LATERAL LINE, 45 DEGREE ELL
TO REQUIRED DEPTH
REMOTE CONTROL VALVE
6" VALVE BOX EXTENSIONS AS
PVC MAINLINE
REQURED DEPTH
WATERPROOF WIRE CONNECTORS
1" DIA. WIRE COIL - 24" LONG
LAWN SPRAY HEAD
RAINBIRD SPX 1/2" X 12" SWING PIPE
LAWN POP-UP HEAD, INSTALL
1/4" ABOVE FINISH GRADE
PVC LATERAL PIPE (SIZE
AROUND BODY
TAMP SOIL FIRMLY AROUND BODY
1/4" ABOVE FINISH GRADE
NOTED ON PLAN)
LASCO UNITIZED O-RING SWING JOINT ASSY.
SIZED TO MATCH INLET SIZE OF THE HEAD
ROTARY HEAD
INSTALL ROTARY HEAD, SET
BRICK WALL
WIRELESS RAIN/FREEZE SENSOR
FINISH GRADE
FINISH GRADEFINISH GRADE
10" RAINBIRD VB VALVE BOX W/ PURPLE
LID SET 1/4" ABOVE FINISH GRADE
WALLMOUNT SENSOR
M x F.I.P.S. COUPLING
PVC LATERAL LINE
BRICK SUPPORT
(1 - EA. CORNER)
24" MIN.
PVC MAINLINE
SCH. 80 UNION
CONTROL ZONE KIT W/ DECODER
SCH. 80 UNION
DISC FILTER
PRESSURE REGULATING VALVE
REMOTE CONTROL DRIP ZONE KIT
12" MIN.
FINISH GRADE
AIR RELIEF VALVE KIT:
DRIPLINE TUBING
AIR RELIEF VALVE
RAINBIRD X1700 AR VALVE KIT
18" MIN.
36" MAX.
2" DOUBLE CHECK ASSEMBLY INSTALLED
2" WATER METER INSTALLED PER CODE
2" ISOLATION VALVE INSTALLED BY L.I.C.
2" WYE "Y" STRAINER INSTALLED BY L.I.C.
WATER SOURCE LAYOUT
BRICK SUPPORT CONT. 2
LAYERS MIN.(PER LOCAL
WYE "Y" STRAINER
CODE)
WYE "Y" STRAINER
6" WASHED PEA GRAVEL
(1" DIAMETER GRAVEL)
6" WASHED PEA GRAVEL
(1" DIAMETER GRAVEL)
FINISH GRADE
PER CITY CODE BY L.I.C.
12"x17" RAINBIRD VB VALVE
BOX WITH PURPLE LID SET
1/4" ABOVE FINISH GRADE
12"x17" RAINBIRD VB VALVE BOX W/ PURPLE
LID SET 1/4" ABOVE FINISH GRADE
FINISH GRADE
6" RAINBIRD PVB VALVE BOX W/
PURPLE LID SET 1/4" ABOVE
FINISH GRADE
FINISH GRADE
MASTER VALVE
FINISH GRADE
WATERPROOF WIRE CONNECTIONS
1" DIA. WIRE COIL - 24" LONG
2" MASTER VALVE INSTALLED BY L.I.C.
BY GENERAL CONTRACTOR
EMITTERDRIPLINE
DRIPLINE
EMITTER
QF DRIPLINE HEADER
PER MANUFACTURER
CLASS 200 PVC
PVC HEADER
TYPICAL DRIPLINE LAYOUT
ROW SPACING PER
MANUFACTURER
ISOLATION VALVE
BRASS CROSS HANDLE
S X MPT PVC ADAPTER
GATE VALVE
PVC MAINLINE
FINISH GRADE
PVC LATERAL
WASHED PEA GRAVEL (PER
LOCAL DEPTH CODE)
WASHED PEA GRAVEL (PER
LOCAL DEPTH CODE)
BRICK SUPPORT CONT. 2
LAYERS MIN.(PER LOCAL
CODE)
BRICK SUPPORT CONT. 2
LAYERS MIN.(PER LOCAL
CODE)
BRICK SUPPORT CONT. 2
LAYERS MIN.(PER LOCAL
CODE)
MAINLINE
WASHED PEA GRAVEL (PER
LOCAL DEPTH CODE)
PVC MAINLINE
CUT SIDES OF VALVE BOX SECTION
TO ALLOW BOX TO EXTEND TO THE
BOTTOM OF TRENCH
6" VALVE BOX EXTENSIONS
AS REQ'D
6" VALVE BOX EXTENSIONS
AS REQ'D
18" ROW
SPACING
DRIPLINE EMITTER
4" MIN.
FINISH GRADE
CLASS 200 PVC HEADER
TYPICAL SUBSURFACE DRIPLINE LAYOUT
SIDE VIEW
CONTROL ZONE KIT
DRIPILINE TUBING
LINE FLUSHING VALVE
AIR RELIEF VALVE
CLASS 200
EMITTER
DRIPLINE
PVC HEADER
CLASS 200
PVC HEADER
CLASS 200
PVC HEADER
1" REMOTE CONTROL
DRIP VALVE
CLASS 200 PVC HEADER
6" WASHED PEA GRAVEL
(1" DIAMETER GRAVEL)
TYPICAL DRIPLINE LAYOUT TYPICAL DRIPLINE LAYOUT
CLASS 200 PVC
PVC HEADER CLASS 200 PVC
PVC HEADER
EMITTER
DRIPLINE
DRIP INDICATOR HEAD
ROW SPACING PER
MANUFACTURER
ROW SPACING PER
MANUFACTURER
ROW SPACING PER
MANUFACTURER
FLUSH
VALVE
WASHED PEA GRAVEL (PER
LOCAL DEPTH CODE)WASHED PEA GRAVEL (PER
LOCAL DEPTH CODE)
18" MIN.
36" MAX.
18" MIN.
36" MAX.
18" MIN.
36" MAX.
NOT TO SCALE C SHIDC
NOT TO SCALE C SHIDC NOT TO SCALE C SHIDC
NOT TO SCALE C SHIDC C SHIDC
NOT TO SCALE C SHIDC NOT TO SCALE C SHIDC NOT TO SCALE C SHIDC
FINISH GRADE
FINISH GRADE
SET 1/4" ABOVE
6" VALVE BOX,
COMPRESSION TEE
6" WASHED PEA GRAVEL
(1" DIAMETER GRAVEL)
FINISH GRADE
6" RAINBIRD PVB VALVE BOX W/
PURPLE LID SET 1/4" ABOVE
DRIPLINE TUBING
EASY FIT FLUSH CAP
NOT TO SCALE C SHIDC
FLOW/GPM:
0 - 4.0
4.1 - 9.5
9.6 - 14.5
14.6 - 27.0
1/2"
3/4"
1"
1-1/4"
PIPE SIZE:
55.1 - 70.0
35.1 - 55.0
27.1 - 35.0
2-1/2"
1-1/2"
2"
NOT TO SCALE C SHIDC
NOT TO SCALE C SHIDC
NOT TO SCALE C SHIDCNOT TO SCALE C SHIDC NOT TO SCALE C SHIDC NOT TO SCALE C SHIDC
NOT TO SCALE C SHIDC NOT TO SCALE C SHIDC
AIR RELIEF
VALVE
FLUSH
VALVE
FLUSH
VALVEFLUSH
VALVE
FLUSH
VALVE
AIR RELIEF
VALVE
PER MANUFACTURER PER MANUFACTURER
NOT TO SCALE C SHIDC
DRIP FLUSH VALVE
NOT TO SCALE
C SHIDCNOT TO SCALE
12"x17" RAINBIRD VB VALVE BOX W/ PURPLE
LID SET 1/4" ABOVE FINISH GRADE 12"x17" RAINBIRD VB VALVE BOX W/ PURPLE
LID SET 1/4" ABOVE FINISH GRADE
REMOTE CONTROL VALVE W/ DECODER
PVC PIPE SIZE CHART
NOT TO SCALE C SHIDC
AIR RELIEF
VALVE
QF DRIPLINE HEADER
SUPPLY/
EXHAUST
HEADER
6" MAX.
DRIP INDICATOR HEAD
DRIP INDICATOR HEAD
DRIP INDICATOR HEAD
USE BOTTOM INLET ONLY
PVC LATERAL PIPE (SIZE
AS NOTED ON DRAWING)
OPERATION INDICATOR HEAD, INSTALL
1/4" ABOVE FINISH GRADE
FINISH GRADE
NOT TO SCALE C SHIDC
MASTER VALVE W/ DECODER
PVC LATERAL PIPE (SIZE
NOTED ON PLAN)
70.1 - 110.0 3"
RAINBIRD SPX 1/2" X 12" SWING PIPE
QF DRIPLINE HEADER QF DRIPLINE HEADER QF DRIPLINE HEADER
QF DRIPLINE HEADER
QF DRIPLINE HEADER
PVC PIPE
1804 W/ PLASTIC SPRAY
SPX SWING PIPE INSTALLED
NOZZLE ON 1/2" RAINBIRD
TREE SPRAY HEAD
ABOVE FINISH GRADE
NOT TO SCALE C SHIDC
CLASS 200 PVC, 45 DEGREE
ELL TO REQ. DEPTH
INTERNATIONAL INC.pross design group, incorporated5310 Harvest Hill Road, Suite 180, Dallas, Texas 75230. 972/759-140006/21/21
Irrigation in Texas is regulated by the Texas Commission of Environmental
Quality (TCEQ), MC-178, P.O. Box 13087, Austin, Texas, 78711-3087.
TCEQ website is: www.tceq.state.tx.us
L3.03
IRRIGATION SPECIFICATIONS
AND LEGEND
NOTES:
1.ALL VALVE WIRING SHALL BE PAIGE P7072D 14-2UF DOUBLE JACKETED. REFER TO MANUFACTURER'S RECOMMENDATIONS
FOR PROPER WIRE SIZE. WIRE SPLICES SHALL BE RAINBIRD DBRY20 PERMANENT AND WATERPROOF PER THE
SPECIFICATIONS.
2.COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH LANDSCAPE CONTRACTOR TO ENSURE ALL PLANT MATERIAL WILL
BE WATERED IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS.
3. PIPING AND VALVES IN PAVING SHOWN FOR CLARITY, INSTALL IN ADJACENT PLANTING BED OR LAWN AREA.
4. LATERAL PIPING SHALL HAVE A MINIMUM OF 12" OF COVER. MAINLINE AND PIPING UNDER PAVING SHALL HAVE A MINIMUM
OF 18" OF COVER. ALL FITTINGS TO BE SCHEDULE 40 PVC. USE WELD-ON #705 SOLVENT AND #P-68 PRIMER FOR PVC
CONNECTIONS PER THE SPECIFICATIONS.
5.SIZE PIPING PER MANUFACTURER'S RECOMMENDATIONS OF NOT EXCEEDING 5 FPS. REFERENCE CHART.
6.CONNECT LAWN SPRAY, TREE SPRAY, AND DRIP INDICATOR HEADS TO LATERAL PIPING WITH RAINBIRD 1/2" SPX SWING PIPE.
CONNECT ROTARY HEADS TO LATERAL PIPE WITH LASCO #T722 SERIES"UNITIZED", O-RING SWING JOINTS .
7. PERFORM ELECTRICAL WORK IN ACCORDANCE WITH LOCAL BUILDING CODE. POWER (120V) SHALL BE LOCATED IN A
JUNCTION BOX AND HARDWIRED WITHIN FIVE (5') FEET OF CONTROLLER LOCATION BY GENERAL CONTRACTOR.
8. INSTALL REMOTE CONTROL VALVES WITH DECODER AND WIRE SPLICES IN TEN (10") INCH RAINBIRD VB VALVE BOXES.
9. INSTALL SLEEVES UNDER ALL HARDSCAPE SURFACES SUCH AS ROADS, DRIVES, WALKS, ETC. WHETHER SHOWN OR NOT.
SLEEVES SHALL BE CLASS 200 PVC, SIZED AS NOTED ON PLANS AND INSTALLED BY LANDSCAPE IRRIGATION CONTRACTOR.
10. ADJUST NOZZLES FOR SITUATIONS THAT REQUIRE LESS THAN 90 DEGREE RADIUS SPRAY. NO OVERSPRAY ALLOWED ON
ANY HARDSCAPE SURFACES.
11. DESIGN PRESSURE IS 61.0 PSI. STATIC PRESSURE IS 70 PSI. TEN DAYS PRIOR TO START OF CONSTRUCTION, VERIFY STATIC
PRESSURE. IF STATIC PRESSURE IS LESS THAN STATED DO NOT START WORK UNTIL NOTIFIED TO PROCEED.
12. MINIMUM DISTANCE BETWEEN MAIN LINE AND LATERAL LINE FITTINGS (EXCEPT FOR REDUCER BUSHINGS) TO BE EIGHTEEN
(18") INCHES AND MINIMUM HORIZONTAL DISTANCE OF TWENTY-FOUR (24") INCHES BETWEEN ANY VALVES
THAT ARE INSTALLED SIDE BY SIDE.
13. INSTALL REMOTE CONTROL DRIP ZONES WITH DECODER IN TWELVE BY SEVENTEEN (12"x17") INCH RAINBIRD VB VALVE BOX.
14. INSTALL DRIPLINE MINIMUM OF 2" AND A MAXIMUM OF 4" FROM HARDSCAPE SURFACES. DO NOT EXCEED MANUFACTURER'S
RECOMMENDATIONS OF 5'-0" PER SECOND IN DRIPLINE.
15. PROVIDE AND INSTALL DISTRIBUTION TUBING, STAKES, EMITTERS, TRANSFER FITTINGS, DIFFUSER BUG CAP, QF DRIPLINE
HEADERS, CONTROL ZONE KITS, ETC. NECESSARY FOR PROPER INSTALLATION OF THE DRIP SYSTEM. ALL PVC HEADER
PIPING TO BE CLASS 200 PVC SOLVENT WELD PIPE. INSERT XF BARBED INSERT FITTINGS PER MANUFACTURER'S
RECOMMENDATIONS. INSTALL RAINBIRD OPERATION INDICATOR FOR EACH DRIP ZONE.
16. AIR RELIEF VALVE TO BE RAINBIRD AR VALVE KIT INSTALLED IN A SIX-INCH (6") RAINBIRD PVB VALVE BOX WITH BLACK LID AND
6" OF GRAVEL SUMP. FLUSH VALVES TO BE 1/2" LASCO BALL VALVE ON IPS FLEXIBLE PIPE AND 1/2" SCHEDULE 40 FITTINGS
INSTALLED IN A SIX-INCH (6") RAINBIRD PVB VALVE BOX WITH BLACK LID AND 6" OF GRAVEL SUMP.
17. ALL XFS CV DRIPLINE AND DISTRIBUTION TUBING TO BE INSTALLED BELOW FINISH GRADE APPROXIMATELY 4" TO 6" PER
MANUFACTURER'S RECOMMENDATIONS. ALL DRIPLINE TO BE INSTALLED MIN. OF 14" AND MAX. OF 20" ROW SPACING UNLESS
INSTRUCTED OTHERWISE. VERIFY THE EXACT EMITTER FLOW, EMITTER SPACING, AND ROW SPACING WITH MANUFACTURER
PRIOR TO INSTALLING TO PROVIDE PROPER PRECIPITATION RATE BASED ON PLANT MATERIAL AND SOIL TYPE. TUBING TO BE
STAKED WITH RAINBIRD 12 GA. GALVANIZED TIE DOWNS. INSTALL STAKES EVERY 3'-0" ALONG ENTIRE LENGTH OF TUBING
AND A MINIMUM OF 24" FROM ANY FITTINGS.
18. INCLUDE THE FOLLOWING ALLOWANCES FOR PROVIDING AND INSTALLING AIR RELIEF VALVES AND FLUSH VALVES FOR THE
DRIP SYSTEM. EXACT QUANTITY AND LOCATION OF THESE DEVICES WILL BE DETERMINED AT THE TIME OF INSTALLATION. IN
GENERAL, ALL AIR RELIEF VALVES WILL BE INSTALLED AT THE HIGH POINTS AND FLUSH VALVES WILL BE INSTALLED AT THE
LOW POINTS OF EXHAUST HEADER. ALLOW FOR APPROXIMATELY ONE (1) AIR RELIEF VALVE AND APPROXIMATELY ONE (1)
FLUSH VALVE FOR EACH DRIP ZONE KIT.
19. PROVIDE ALL LABOR AND MATERIAL NECESSARY TO INSTALL A RAINBIRD TWO-WIRE SYSTEM PER THE MANUFACTURER'S
RECOMMENDATIONS. THIS WORK TO INCLUDE BUT NOT LIMITED TO ESP-LXD CONTROLLER, FD-TURF DECODERS, PAIGE
P7072D COMMUNICATION WIRE, PBC-LXD PROGRAM BACKUP CARTRIDGE, LSP1TURF LINE SURGE PROTECTION, DPU-210
PROGRAMMING UNIT, GROUNDING, ETC. FOR A COMPLETE AND FULLY AUTOMATED IRRIGATION SYSTEM. FOR ANY
QUESTIONS REGARDING THIS WORK, CONTACT THE LOCAL RAINBIRD REPRESENTATIVE.
20. DO NOT INSTALL ANY MAINLINES, VALVES, OR CONTROL WIRES WITHIN THE R.O.W. UNLESS CITY APPROVED.
21. PROVIDE ALL LABOR AND MATERIAL NECESSARY TO HAND DIG WITHIN ALL EXISTING TREE ROOT ZONES. CONTRACTOR
MUST STAKE DITCHES AND RECEIVE APPROVAL FROM LANDSCAPE ARCHITECT PRIOR TO ANY TRENCHING OR DIGGING.
22. ALL STATE OF TEXAS LAWS/RULES AND ALL LOCAL CODES/ORDINANCES ARE MADE PART OF THESE PLANS AND
SPECIFICATIONS WHETHER SHOWN OR NOT. THESE LAWS AND ORDINANCES WILL SUPERCEDE THE PLANS, DETAILS,
AND/OR SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR IS CAUTIONED THAT HE IS TO INCLUDE ANY AND ALL COST
NECESSARY TO MEET OR EXCEED THE LAWS OF THE STATE OF TEXAS OR LOCAL CODES CONCERNING LANDSCAPE
IRRIGATION. A LICENSED IRRIGATOR OR LICENSED IRRIGATION TECHNICIAN SHALL BE ON-SITE AT ALL TIMES WHILE THE
LANDSCAPE IRRIGATION SYSTEM IS BEING INSTALLED PER CITY OF COPPELL REQUIREMENTS.
23. ALL OF THE EQUIPMENT FOR THIS PROJECT TO BE PURPLE PER STATE AND LOCAL CODES FOR FUTURE WELL CONNECTION.
THIS EQUIPMENT TO INCLUDE BUT NOT LIMITED TO THE HEADS, VALVES, PIPES, DRIPLINE, VALVE BOX LIDS, ETC.
REFER TO SPEC.
REFER TO SPEC.
MANUFACTURER
ROTARY HEAD
LATERAL PIPING
MAINLINE PIPING
FULL-CIRCLE
RAINBIRD (40 PSI)
IRRIGATION LEGEND:
SYMBOL
ROTARY HEAD
LAWN SPRAY HEAD
DESCRIPTION
PART-CIRCLE
RAINBIRD (40 PSI)
RAINBIRD (30 PSI)
5004-CV-NP WITH #8.0 NOZZLE ON 3/4"
3/4" & LARGER - CLASS 200 PURPLE PVC
2-1/2" CLASS 200 PURPLE PVC
1804-CV-NP W/ MPR PLASTIC NOZZLE ON
5004-CV-NP WITH #4.0 NOZZLE ON 3/4"
MODEL NO,
BALL VALVE LASCO COMPACT, LINE SIZE
1/2" - CLASS 315 PURPLE PVC
ON RAINBIRD 1/2" SPX SWING PIPE
TREE SPRAY HEAD RAINBIRD (30 PSI)
TREE SPRAY HEAD RAINBIRD (30 PSI)
ROTARY HEAD
FULL-CIRCLE
RAINBIRD (40 PSI)5004-CV-NP WITH #3.0 NOZZLE ON 3/4"
ROTARY HEAD
PART-CIRCLE
RAINBIRD (40 PSI)5004-CV-NP WITH #1.5 NOZZLE ON 3/4"
REMOTE CONTROL RAINBIRD PESB-NP W/ DECODER AND PRS-D PRESSURE
VALVE
REMOTE CONTROL RAINBIRD XCZ-100-PRB-COM-NP CONTROL ZONE KIT
DRIP VALVE W/ DECODER, REFER TO PLAN FOR SIZE
REGULATOR, REFER TO PLANS FOR SIZE
PIPING
DRIP HEADER REFER TO SPEC.3/4" CLASS 200 PURPLE PVC UNLESS NOTED
OTHERWISE
FEBCOBACKFLOW
GPM (APPROX.)
STATION NUMBER
PREVENTER
VALVE SIZE
#850BV, REFER TO PLAN FOR SIZE
RAINBIRDMASTER VALVE PEB W/ DECODER, REFER TO PLAN FOR SIZEM
REFER TO SPEC.WATER METER PER LOCAL BUILDING CODEW
DRIPLINE TUBING
PLANTING BED RAINBIRD
WYE STRAINER #650, REFER TO PLAN FOR SIZEYFEBCO
ISOLATION VALVE NIBCO #T-29, REFER TO PLAN FOR SIZEI
FITTINGS, TDS-050 GALVANIZED STAKES,DRIPLINE TUBING
TURF SOD RAINBIRD XFSCV-06-18-PS AT 18" O.C. WITH XF INSERT
QF HEADERS AND OPERATION INDICATOR
FITTINGS, TDS-050 GALVANIZED STAKES,
XFSCV-06-18-PS AT 18" O.C. WITH XF INSERT
RAINBIRDCONTROLLER ESP-50LXD WALLMOUNT SERIES WITH
WIRELESS WR2 RAIN/FREEZE SENSOR
QF HEADERS AND OPERATION INDICATOR
ORNAMENTAL
SHADE
1804-NP W/ 6Q PLASTIC BUBBLER NOZZLE
1804-NP W/ 10Q MPR PLASTIC NOZZLES
ON RAINBIRD 1/2" SPX SWING PIPE
ON RAINBIRD 1/2" SPX SWING PIPE
LASCO T722-212 SWING JOINT
LASCO T722-212 SWING JOINT
LASCO T722-212 SWING JOINT
LASCO T722-212 SWING JOINT