Old Town Phase 3-PN221221COVER SHEET 105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C1NOVEMBER 2022Grading and UtilitiesTITLESHEET NOINDEX TO DRAWINGSLOCATION MAPN.T.S. MIXED USEENGINEER:Contact Person: Mike Glenn, P.E.(972) 717-5151Irving, Texas 750384500 Fuller Drive, Suite 220Glenn Engineering CorporationforOLD TOWN ADDITIONThe City of Coppell, TexasC1COVER SHEETC2 PLATC3PLATA005DETAIL SITE PLANC4PAVING AND GRADING PLANC5UTILITY PLANC6CITY WATER DETAILSC7CITY PAVING DETAILSL1.01LANDSCAPE PLANTING PLANL1.02LANDSCAPE DETAILSL2.01IRRIGATION PLANL2.02IRRIGATION DETAILSLOT 4R, BLOCK DARCHITECT:Contact Person: William Peck AIA(972) 221-1424Lewisville, Texas 75057105 West Main StreetWilliam Peck & Assoc., Inc.SITE767 West Main StreetDEVELOPER:8/29/22(817) 939-3379Coppell, Texas 75019767 West Main StreetDiana Ahmad111/8/22CITY COMMENTS11/20/222CITY COMMENTS PLAT-SHEET 1 105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C28/29/22111/8/22CITY COMMENTS PLAT-SHEET 2 105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C38/29/22111/8/22CITY COMMENTS SHEET 5 OF 56 A-005DETAILED SITE PLANSheet Number: Scale: Drawn: Job: REVISIONSThese plans are intended to provide the basic construction information necessary tosubstantially complete this structure. These construction documents must be verified andchecked by the builder or person in authority of this project. Any discrepancy, error, and/or omissions, if any, are to be brought to the attention of the Designer prior to anyconstruction or purchases being made. It is recommended that the owner or builder obtaincomplete engineering services for: foundation, HVAC, and structural, prior to constructionof any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions takeprecedence over any part of these construction documents which may conflict with same,and must be strictly obeyed and followed before and during construction.THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OFWILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED ORREPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSEDWRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTSRESERVEDISSUE DATE:WILLIAM PECK &A S S O C I A T E S I N C.A R C H I T E C T SLewisville, Tx 972) 221-1424MIXED-USE767 WEST MAIN STREETCOPPELL, TEXAS 75019REF. PLAN M.W. 2022-08-08 FOR P&Z REVIEW 22-172-001 2022-08-26 FOR PERMIT 2022-08-26 2022-08-26 1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8")21R(0'-11")1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8")21R(0'-11")N 12'-1 1/2"3'-0"4'-0"3'-0"10'-0"15'-0"19'-0"11'-0"5'-0"5'-0"5'-0" 8'-8"9'-0"3'-0"20'-6"2'-10"9'-0"9'-0"9'-0"2'-10"20'-6"3'-0"9'-0"8'-8" 37'-2 3/8"9'-0"22'-2 1/8"9'-0"21'-11"9'-0"6'-8 1/2"10'-0"18'-0"24'-0"COMMON ACCESS AND DRAINAGE EASEMENT4'-0"5'-6"7'-0"TRAFFIC RATED BOX FDC 5' UTILITY EASEMENT EXISTING FIRE HYDRANT WATER EASEMENT FDC EXISTING LIGHT POLE EXISTING LIGHT POLEEXISTING LIGHT POLE NEW CONCRETE PAVING VAULT FDC 8,550 SQ.FT. (0.196 ACRES) EXISTING BUILDING RETAIL 20 PARKING SPACES OR 10 DOUBLE PARKING SPACES LOT R3 BLOCK D GRASS PAVERS GRASS PAVERS COMMON AREA LOT 17R-X ALLEY S 01˚47' 53" E 89.89'N 88˚12' 07" E 95.00'N 01˚47' 53" W 90.00'N 88˚12' 07" E 95.00'S 88˚12' 07" W 95.00'S 01˚47' 53" E 90.00' WEST MAIN STREET FIRE RISER ROOM 2-CAR GARAGE 2-CAR GARAGE FRONT PORCH RESIDENTIAL ENTRY LOT R4 BLOCK D RETAIL/ RESTAURANT LOT R2 BLOCK D N 01˚47' 53" W 80.00' S 01˚47' 53" E 80.00' N 01˚47' 53" E 115.00' S 01˚47' 53" E 115.00' W RETAIL RESIDENTIAL ENTRY 10,925 SQ.FT. (0.251 ACRES)123456789101112131415UPCustom Text NEW LANDSCAPING 1 PARKING SPACE 3 PARKING SPACES NEW SIDEWALKNEW SIDEWALK NEW SIDEWALKNEW LANDSCAPINGPROPOSED LOCATION OF A/C COMP.NEW SIDEWALK3 PARKING SPACES 1 PARKING SPACE NEW LANDSCAPING LADDER TO ROOF ABOVE NEW SIDEWALK NEW LANDSCAPING NEW LANDSCAPING NEW LANDSCAPING 9 PARKING SPACES NEW SIDEWALK 2 RESIDENCE PARKING SPACE 2 RESIDENCE PARKING SPACE TYPE AREA FACTOR REQUIR ED PROVIDED ON-SITE PROVIDED ON-STREET SHARED TOTAL PR OVIDED R ESIDENTIA L 99 TOWNHOUSE PH I - IV }+ George Unit 96 UNITS 2.5 240 2 12 22 234 RETAIL R3, APARTMENT 1 2.5 3 4 4 RETAIL RETAIL R1 (Tangerine Salon)5039 200 25 2 13 15 RETAIL R3 2577 200 13 5 8 13 RETAIL R4 313 4 200 16 5 9 14 COTTAGE 11 (f or mer Frost Cupcakery)3826 200 19 2 3 5 COTTAGE 13 (Remainder Retail )964 200 5 SERVICE S1 2288 200 11 6 7 13 OFFICE SERVICE 25301 COTTAGE 05 143 0 300 5 2 0 2 COTTAGE 06 18 5 7 300 6 2 0 2 COTTAGE 09 15 65 300 5 3 4 7 COTTAGE 10 1606 300 5 2 4 6 COTTAGE 12 2848 300 9 2 5 7 COTTAGE 14 (Pence Of f i ce)1448 300 5 2 3 5 RETAIL R2 3000 300 10 9 5 14 SER VICE S2 5531 300 18 7 6 13 RETAIL R5 3974 300 13 4 8 12 GEORGE - OFFICE 2042 300 7 2 5 7 RESTAURANT 22786 LOCAL DINER 3574 10 0 36 35 11 46 GEOR GE 318 6 10 0 32 0 10 10 TWISTED 8026 10 0 80 0 13 13 RESTAURANT F2 8000 10 0 80 0 9 9 MEDICAL 2144 COTTAGE 13 214 4 17 5 12 3 6 9 PAVILLION THEATER HALL 445 SEATS 1:3 14 9 90 53 14 3 BLACK BOX 175 SEATS 1:3 59 MULTI-PURPOSE-EV ENT 1966 20 SHARED ON-STR EET 404 404 TOTAL ALL 888 407 608 10 15 TOTAL R ESIDENTIA L ONLY 248 224 22 246 TOTAL COMMERCIAL ONLY 640 18 3 586 769 Old Town Shar ed Par king Tabulation EXCLUDED FROM PARKING REQUIREMENTS RETAIL R4, APARTMENTS 2 2.5 5 8 8 18041 N SCALE: 1" = 10'1 DETAILED SITE PLAN SUBJECT PROPERTY LOCATION MAP CODE SUMMARY USE AND OCCUPANCY CLASSIFICATION: MERCANTILE - 3,134/60 = 53 OCCUPANTS TOTAL OCCUPANCY - 53 OCCUPANTS CONSTRUCTION TYPE: V-B FIRE SPRINKLER SYSTEM: REQUIRED MINIMUM EXITS REQUIRED: 2 PROVIDED: 2 SITE DATA TABLE LOT-4R BLK-D 767 WEST MAIN ST. EXISTING ZONING - PD-250R8-H PROPOSED ZONING - PD-250R25-H PROPOSED USE - MIXED USE: RETAIL RESIDENTIAL AREA OF PROPOSED USE - 0.251 ACRES BUILDING AREA CALCULATIONS A/C SPACE: RETAIL - 3,134 SQ. FT. RESIDENCE - 1ST FLOOR (ENTRY) - 410 SQ. FT. 2ND FLOOR - 4,600 SQ. FT. FRONT PORCH - 665 SQ. FT. GARAGES - 960 SQ. FT. BALCONY - 376 SQ. FT. FIRE RISER ROOM - 56 SQ. FT. TOTAL BUILDING FOOTAGE -10,201 SQ. FT. BUILDING HEIGHTS (T.O. PARAPET) : 33'-11" PARKING CALCULATIONS: RESIDENCE REQUIRED - 5 SPACES PROVIDED - 4 SPACES (GARAGE) + 4 SPACE= 8 TOTAL SPACES RETAIL REQUIRED - 3,134/ 200 = 16 SPACES PROVIDED PARKING - SHARED PARKING + 5 SPACES REQUIRED TOTAL - 21 SPACES PROVIDED TOTAL - SHARED PARKING + 13 SPACES ( NOTE: SQUARE FOOTAGE FOR PARKING CALCULATIONS DOES NOT INCLUDE GARAGES OR PORCHES) PROPOSED LOT COVERAGE - 48% PD CONDITIONS: 1. THE DIRECTOR OF COMMUNITY DEVELOPMENT SHALL HAVE THE AUTHORITY TO ADMINISTRATIVELY APROVE THE PROPOSED SIGNAGE FOR THIS DEVELOPMENT IN ACCORDANCE WITH PLANNED DEVELOPMENT REGULATIONS FOR PD-250R8-H AND THE HISTORIC DISTRICT. 2. THE SECOND FLOOR RESIDENCE SHALL BE DEVELOPED IN ACCORDANCE WITH LOCAL ORDINANCE AND BUILDING CODES; AMD SHALL BE USED FOR RESIDENTIAL PURPOSES ONLY. OWNER & PROFESSIONAL INFORMATION DEVELOPER DIANA AHMAD 767 WEST MAIN ST. COPPELL, TEXAS 75019 P: 817-939-3379 ARCHITECT BILL PECK WILLIAM PECK AND ASSOC., INC. 105 WEST MAIN ST. LEWISVILLE, TX 75057 P: 972-221-1424 LANDSCAPE ARCHITECT CAROL FELDMAN FELDMAN DESIGN STUDIOS P.O. BOX 832346 RICHARDSON, TEXAS 75083 T: (972) 980-1730 CIVIL ENGINEER MIKE GLENN GLENN ENGINEERING 105 DECKER COURT, SUITE 910 IRVING, TEXAS 75062 P: (972) 717-5151 F: (972) 717-2176 6040.001/2 irs6150.001/2 irs6160.001/2 irs6170.001/2 irs6180.001/2 irs6190.001/2 irs6200.001/2 irsCCELEC.DCURB INLET TOP=516.60' FL=512.50' 5.0'5.0'10.0'Water Esmt. 5' UTILITY EASEMENT 10.0'N 88°12'07" E 95.00'6" Curb EXISTINGLANDSCAPEDMEDIANISLANDXTP 516.01XTP 515.96XTP 516.25 TP 516.95S 88°12'07" W95.00'N 01°47'53" W 115.00'S 01°47'53" E115.00'N FDC FDC 47' 53" W 89.89' 10,925 SQ.FT. (0.251 ACRES) 1 PARKINGSPACE3 PARKINGSPACES1 PARKINGSPACE 8 PARKING SPACES 1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8" ) 21R(0'-11" ) 1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8" ) 21R(0'-11" ) DE106 DE101DE101DE101 DE104 DE105 DE104 DE103 DE102 DI101 DI101 DI102 DI102FF 517.354" SANITARY SEWER9'-6"9.00'9.25'3.50'18.20'3.50'9.80'9.00'9.80'3.50'20.00'3.50'8.75 FIREEX. 2" MAINEX. 6" FIREEX. 6" FIREFIREEX. STREET LIGHTPAVING ANDPaving and Grading PlanScale 1" = 10'GRADING PLAN 105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C4PAVING LEGENDSIDEWALK (PRIVATE) NEWCONC PAVING PER CITY OFCOPPELL STD. DETAIL 2170(PRIVATE) NEW 6" THK CONC PAVING(4,000 PSI) (#3 @ 18" O.C.E.W)SEE ALPHA TESTING REPORT NO. G120968 FOR SUBGRADEREQUIREMENTSGENERAL GRADING AND PAVING NOTES1.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THESE PLANS AND LOCAL GOVERNINGAUTHORITIES STANDARDS AND SPECIFICATIONS.2.PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL MAKE CERTAIN THAT ALLREQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NO CONSTRUCTION ORFABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED AND THOROUGHLYREVIEWED ALL PLANS AND OTHER DOCUMENTS APPROVED BY ALL OF THE PERMITTINGAUTHORITIES.3.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE PLANS ANDSPECIFICATIONS AND THE REQUIREMENTS AND STANDARDS OF THE LOCAL GOVERNINGAUTHORITY.4.IN THE EVENT AN ITEM IS NOT COVERED IN THE CITY OF COPPELL SPECIFICATIONS, THECITY ENGINEER'S DECISION SHALL APPLY.5.GRADING SHOWN IN PAVED AREAS IS FINISHED GRADE. CONTRACTOR SHALL GRADE TOSUBGRADE IN THESE AREAS. SUBGRADE UNDER PAVEMENT SHALL BE COMPACTED TO 95%OF MAXIMUM DENSITY PER ASTM D698 PER THE REQUIREMENTS OF THE GEOTECHNICAL REPORT G120968 BY ALPHA TESTING.6. ALL CONCRETE SIDEWALKS SHALL BE PER THE REQUIREMENTS OF CITY STANDARD DETAIL2170.7. ALL CONCRETE DRIVES SHALL BE 6 INCHES AND HAVE A MINIMUM COMPRESSIVESTRENGTH OF 4,000 PSI AT 28 DAYS.8/29/22111/8/22CITY COMMENTSTOTAL IMPERVIOUS AREA = 10,065 S.F.11/20/222CITY COMMENTS 6040.001/2 irs6150.001/2 irs6160.001/2 irs6170.001/2 irs6180.001/2 irs6190.001/2 irs6200.001/2 irsCCELEC.DCURB INLET TOP=516.60' FL=512.50' 5.0'5.0'10.0'Water Esmt. 5' UTILITY EASEMENT 10.0'N 88°12'07" E 95.00'6" Curb EXISTINGLANDSCAPEDMEDIANISLANDXTP 516.01XTP 515.96XTP 516.25 TP 516.95S 88°12'07" W95.00'N 01°47'53" W 115.00'S 01°47'53" E115.00'N FDC FDC 47' 53" W 89.89' 10,925 SQ.FT. (0.251 ACRES) 1 PARKINGSPACE3 PARKINGSPACES1 PARKINGSPACE 8 PARKING SPACES 1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8" ) 21R(0'-11" ) 1 2 3 4 5 6 7 8 9 10 111213UP22R(0'-7 5/8" ) 21R(0'-11" ) FF 517.35FDCCONNECT NEW 6" FIRETO EX. 6" FIRECONNECT TO EXISTING4" SANITARY SEWER4" SANITARY SEWERINSTALL 6" FIRE LINEVERIFY SIZE WITHFIRE SPRINKLERINSTALLER9.00'9.25'3.50'18.20'3.50'9.80'9.00'9.80'3.50'20.00'3.50'8.75 INSTALL:1" DOMESTIC METER3/4" IRRIGATION METERPER CITY STD. 4135 AND 4145CONNECT TO EXISTING BULLHEAD 1" DOM. SERVICE AND EXISTING 1" IRR. SERVICEFIREEX. 2" MAINEX. 6" FIREEX. 6" FIRE2-18" DIA. METER BOX FORIRRIGATION28" DIA. METER BOX FORDOMESTIC WATERFIREEX. STREET LIGHTINSTALL 1 "DOMESTICWATERLINEINSTALL DOUBLE CHECKON FIRE LINE INRISER ROOM28" DIA. METER BOX FORDOUBLE CHECKINSTALL:1-6" VALVE AT PROP. LINEUtility PlanScale 1" = 10'105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C5GENERAL UTILITY NOTESUTILITY PLAN 8/29/22111/8/22CITY COMMENTS1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THESE PLANS AND CITY OFCOPPELL STANDARDS AND SPECIFICATIONS.2. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL MAKECERTAIN THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEENOBTAINED. NO CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THECONTRACTOR HAS RECEIVED AND THOROUGHLY REVIEWED ALL PLANS ANDOTHER DOCUMENTS APPROVED BY ALL OF THE PERMITTING AUTHORITIES.3. IN THE EVENT AN ITEM IS NOT COVERED IN THE CITY OF COPPELLSPECIFICATIONS, THE ENGINEER'S DECISION SHALL APPLY.4. BARRICADING, TRAFFIC CONTROL, AND PROJECT SIGNS SHALL CONFORM TO"STATE DEPARTMENT OF HIGHWAYS AND PUBLIC TRANSPORTATIONBARRICADING AND CONSTRUCTION STANDARDS".5. THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL VERIFYTHE SUITABILITY OF ALL EXISTING AND PROPOSED SITE CONDITIONSINCLUDING GRADES AND DIMENSIONS BEFORE COMMENCEMENT OF ANYCONSTRUCTION. IN THE EVENT OF ANY CONFLICT AND PRIOR TOCOMMENCEMENT OF ANY CONSTRUCTION, IMMEDIATELY NOTIFY ENGINEER.6. THE LOCATIONS OF UNDERGROUND UTILITIES SHOWN ON THIS PLAN AREBASED ON FIELD SURVEYS AND LOCAL UTILITY COMPANY RECORDS. IT SHALL BETHE CONTRACTOR'S FULL RESPONSIBILITY TO CONTACT THE VARIOUS UTILITYCOMPANIES TO LOCATE THEIR UTILITIES PRIOR TO STARTING CONSTRUCTION.7. CONTRACTOR SHALL VERIFY ALL EXISTING INVERTS, RIM ELEVATIONS ANDSIZES PRIOR TO CONSTRUCTION.8. ALL WATER PIPE SHALL BE CLASS 200 (DR 14) PER AWWA C-900.9. NEW WATER METERS WILL REQUIRE A NEW METER BOX. A DETECTOR CHECKSHALL ALSO BE PROVIDED UNLESS IT HAS BEEN INSTALLED IN RISER ROOM PERCITY OF COPPELL STANDARDS. SEE MECHANICAL PLANS FOR ADDITIONALDETAILS.11/20/222CITY COMMENTS12/9/223CITY COMMENTS CITY WATER DETAILS C6105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET 48/29/22111/8/22CITY COMMENTS11/20/222CITY COMMENTS 105 DECKER COURT, SUITE 910 PHONE 972-717-5151 ENGINEERING IRVING, TEXAS 75062 FAX 972-717-2176 GLENN TEXAS REGISTRATION NUMBER: F-303Scale:Drawn By:Checked By:Project No.:Issue Dates:Review:Permit:Construction:K.K.E.C.M.G. MIXED-USE OLD TOWN ADDITION COPPELL, TEXASRevisions:767 WEST MAIN STREET C7As Shown4"BUILDINGPAVING1/2" REDWOOD LUMBER1" SELF-LEVELING SILICONE SEALERSLOPE 1/4" PER FT.INTERFACEWALK/BUILDING/CURBNOT TO SCALECITY PAVING DETAILS 412"9"9"2"2" 5" 3"#6 @ 2'-6"LONGSECTIONSEAL 12" DEEPHOLE W/MORTAR2-#3 REBARS6 ' -0 "14"14"6" 6 " 27 8" 218"2-1 " Ø HO L ESSTOPPRECAST WHEELNOT TO SCALE8/29/22111/8/22CITY COMMENTS 12345678910111213UP22R(0'-7 5/8" ) 21R(0'-11" ) 12345678910111213UP22R(0'-7 5/8" ) 21R(0'-11" ) FDCEXISTING FIREHYDRANTFDCFDCCOMMON AREA LOT 17R-XALLEYALLEY47' 53" W 89.89'47' 53" E 89.89'N 88˚12' 07" E 95.00'VS 88˚12' 07" W 95.00'FIRERISERROOM2-CARGARAGE1-CARGARAGEFRONT PORCHRESIDENTIALENTRYLOT R4BLOCK DN 01˚47' 53" E 115.00'S 01˚47' 53" E 115.00'WRETAILRESIDENTIALENTRY10,925 SQ.FT. (0.251 ACRES)8,539 SQ.FT. (0.196 ACRES)1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 UPCustom Text36 LIRIOPE 1 SAVANNAH HOLLY ROOT BARRIER, SEE DETAIL 36 LIRIOPE 1 SAVANNAH HOLLY ROOT BARRIER, SEE DETAIL 36 LIRIOPE 1 SAVANNAH HOLLY ROOT BARRIER, SEE DETAIL 1 SALVIA GREGGI 2 GULF MUHLY 3 COREOPSIS 2 PAVONIA 1 MEXICAN OREGANO 3 HINKLEY'S COLUMBINE 4 GULF MUHLY 4 GULF MUHLY 2 PAVONIA 1 MEXICAN OREGANO 3 HINKLEY'S COLUMBINE 12 LIRIOPE TURF TURF ADJACENT LANDSCAPE BERMUDA GRASS SOD PROPERTY LINE ROOT BARRIER FELDMANDESIGN STUDIOSRETAIL 4767 W MAIN STREETSHEET NO. L1.01P.O. Box 832346, Richardson, Texas 75083Mobile: 972 523-4944carol@feldmandesign.comScale: 1" = 10' PLANTING PLAN 00 10'20' DRAWING KEY PLANT LIST LANDSCAPE PLANTING PLAN Jurisdiction of Project Professionals Information Landscaping Requirements Irrigation Requirements Site Location ARCHITECT WILLIAM PECK & ASSOCIATES, INC. LEWISVILLE, TEXAS 972.221.1424 LANDSCAPE ARCHITECT FELDMAN DESIGN STUDIOS P.O. BOX 832346, RICHARDSON, TEXAS 75083 ATTN: CAROL FELDMAN, 972-523-4944 CAROL@FELDMANDESIGN.COM SITE REGULATORY AUTHORITIES: CITY OF COPPELL PLANNING & ZONING 255 PARKWAY BLVD. PO BOX 9478 COPPELL, TX 75019 972 304-7092 TEXAS DEPARTMENT OF LICENSING AND REGULATION ELIMINATION OF ARCHITECTURAL BARRIERS E.O. THOMPSON STATE OFFICE BUILDING 920 COLORADO AUSTIN, TEXAS 78701 (512) 463-3211 (512) 475-2886 (FAX) CITY OF COPPELL LANDSCAPE REQUIREMENTS ARTICLE 34. LANDSCAPE REGULATIONS PD REQUIREMENTS SEC. 12-34-8 MIN REQUIREMENTS FOR OFF-STREET PARKING AND VEHICULAR USE AREAS A. PROJECT IS EXEMPT BY MEETING EXEMPTION PARAGRAPH 1 ARTICLE A AND B INTERIOR LANDSCAPING REQUIREMENTS A. SCREENING OF PARKING B. SCREENING OF A/C UNITS PERIMETER LANDSCAPE REQUIREMENTS A. ALL TREE REQUIREMENTS MET VIA STREET LANDSCAPE NO EXISTING TREES ON SITE. UNDERGROUND AUTOMATIC SPRINKLING SYSTEM PROVIDED. SYSTEM DESIGNED AND INSTALLED ACCORDING TO TCEQ LAWS AND REGULATIONS PROVIDING FOR 100% COVERAGE ON ALL LANDSCAPE AND TURF. THE SYSTEM SHALL INCLUDE A FREEZE-RAIN SENSOR.COPPELL, TEXAS OLD TOWN ADDITIONGround cover only in front of the FDC FORM SAUCER WITH 4" EXISTING TOPSOIL PLANT SHRUB WITH TOP OF ROOTBALL LEVEL WITH EXISTING GRADE 3" SHREDDED MULCH BACKFILL WITH ORIGINAL SOIL, WATER THOROUGHLY TO REMOVE AIR POCKETS SHRUB & ORNAMENTAL GRASS PLANTING DETAIL PLANT SHRUB WITH TOP OF ROOTBALL LEVEL WITH EXISTING GRADE 3" SHREDDED MULCH EXISTING GRADE PLANT INTO TILLED AND AMENDED SOIL NOTE: FOR ROOT-BOUND PLANTS, LOOSEN ROOTS AT OUTER EDGE PERENNIAL PLANTING DETAIL 1. 2. 3. 4. “ ” “” ” “” ” 2X ROOT BALL WIDTH BACKFILL WITH ORIGINAL SOIL, WATER THOROUGHLY TO REMOVE AIR POCKETS PLANT TREE WITH ROOT FLARE LEVEL WITH FINISHED GRADE CUT ROPES AT TOP OF ROOTBALL REMOVE TOP 1/3 OF BURLAP AND ALL WIRE AND OTHER NON-BIODEGRADABLE MATERIAL EXISTING GRADE 3" SHREDDED MULCH EXISTING SOIL TREE PLANTING FORM SAUCER WITH 4" EXISTING TOPSOIL TREE STAKE KIT, TYP. PROTECTION (HOSE COVERED WIRE) AROUND TREE TRUNK ROOT BALL TREE TRUNK NOTE: PLACE 2 TREE STAKES ON SOUTH SIDE OF ROOT BALL AND ONE TREE STAKE ON NORTH SIDE OF ROOT BALL NOTE: TREE STAKES TO BE REMOVED BY OWNER 18 MONTHS AFTER INSTALLATION. CONCRETE BACK OF CURB AT STREET, PARKING OR SIDEWALK RAMP 36" DEPTH DUAL PURPOSE ROOT AND WATER BARRIER. (CENTURY PRODUCTS USA MODEL CR-PE 3-20 OR EQUIVALENT, AS APPROVED BY OWNER.) TREE (AS PER PLAN) GROUNDCOVER OR SHRUBS (AS PER PLAN) SIDEWALK OR OTHER PAVING SOIL SET TOP OF ROOT BARRIER 1/2" BELOW TOP OF CONCRETE CURB FELDMANDESIGN STUDIOSSHEET NO. L1.02 LANDSCAPE DETAILS Scale: 1/2"= 1' TREE STAKE DETAIL Scale: Not to scale TREE PLANTING Scale: Not to scale SHRUB & ORNAMENTAL GRASS PLANTING DETAIL Scale: Not to scale PERENNIAL PLANTING DETAIL P.O. Box 832346, Richardson, Texas 75083Office: 972 980-1730 Mobile: 972 523-4944carol@feldmandesign.comRETAIL 4767 W MAIN STREETCOPPELL, TEXAS OLD TOWN ADDITIONScale: 3/8"= 1' ROOT BARRIER DETAIL 12345678910111213UP22R(0'-7 5/8" ) 21R(0'-11" ) 12345678910111213UP22R(0'-7 5/8" ) 21R(0'-11" ) FDCEXISTING FIREHYDRANTFDCFDC8,550 SQ.FT. (0.196 ACRES)COMMON AREA LOT 17R-XALLEYALLEY47' 53" W 89.89'47' 53" E 89.89'N 88˚12' 07" E 95.00'VS 88˚12' 07" W 95.00'FIRERISERROOM2-CARGARAGE1-CARGARAGEFRONT PORCHRESIDENTIALENTRYLOT R4BLOCK DN 01˚47' 53" E 115.00'S 01˚47' 53" E 115.00'WRETAILRESIDENTIALENTRY10,925 SQ.FT. (0.251 ACRES)8,539 SQ.FT. (0.196 ACRES)1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 UPCustom TextMYMAX. 24" IV LINES & VALVES SHOWN IN CONCRETE AREAS ARE FOR DRAWING CLARIFICATION ONLY. C PR PR PR 1"1 7.6 1"2 1.0 1"3 1.0 1"4 8.2 1.5 1"5 # ## FV Y IV M PR C FELDMANDESIGN STUDIOSSHEET NO. L2.01P.O. Box 832346, Richardson, Texas 75083Mobile: 972 523-4944carol@feldmandesign.comScale: 1"=10' IRRIGATION LAYOUT 00 10'20' Site Location Jurisdiction of Project REGULATORY AUTHORITIES: CITY OF COPPELL PLANNING & ZONING 255 PARKWAY BLVD. PO BOX 9478 COPPELL, TX 75019 972 304-7092 TEXAS COMMISSION ON ENVIRONMENTAL QUALITY (TCEQ) P.O. BOX 13087, AUSTIN, TEXAS 78711-3087 WWW.TCEQ.STATE.TX.US IRRIGATION PLAN RETAIL 4767 W MAIN STREETProfessionals Information ARCHITECT WILLIAM PECK & ASSOCIATES, INC. LEWISVILLE, TEXAS 972.221.1424 LANDSCAPE ARCHITECT FELDMAN DESIGN STUDIOS P.O. BOX 832346, RICHARDSON, TEXAS 75083 ATTN: CAROL FELDMAN, 972-523-4944 CAROL@FELDMANDESIGN.COM COPPELL, TEXAS OLD TOWN ADDITION # ## FV Y IV M PR C . VALVE BOX 12" ROUND PVC WITH LID GRADE VALVE BOX 7" ROUND PVC WITH LID LINE FLUSHING VALVE 2" MIN 2" MIN 2" LAYER OF GRAVEL Weathermatic WALL MOUNT CONTROLLER SMARTLINE SL1600 CONDUIT 115 A.C. POWER SUPPLY LINES GROUNDWIRE TO DRIP LINES OR HEADS COMMON NEUTRAL WIRE CONDUIT 24V A.C. RAIN/FREEZE SENSOR WIRES VALVE CONTROL WIRES - ONE PER VALVE EXPANSION COIL WATER PROOF CONNECTOR ELECTRIC VALVE LOCATE IN VALVE BOX MAINLINE NEUTRAL WIRE TO DRIP LINES OR HEADS 4" MIN. STREET PAVING SLEEVES 18" MIN.18" MIN 15"TO 24" MAX PAVING PVC CAP (TYP.) PVC CAP (TYP.) SLEEVE 15"TO 24" MAX IRRIGATION PIPING 3" MIN 4" MIN 3" MIN 3" MIN 3" MIN 3" MIN 3" MIN 3" MIN 'Y' TYPE STRAINER ISOLATION VALVE WATER METER ISOLATION VALVE WATER METER BLACKFLOW ASSEMBLY TOP VIEW SIDE VIEW STEEL LID BROOKS VALVE BOX NO. 38-T (SEE NOTES) BROOKS VALVE BOX NO. 38-T (SEE NOTES) 1 23 4 5 6 7 8 9 6 3"1.POP-UP SPRAY SPRINKLER. 2.FINISH GRADE. 3.CUR, SIDEWALK OR FOUNDATION. 4.PVC SCHEDULE 80 NIPPLE (6" MIN. LENGTH) 5.PVC T x T 900 ELL 6.MARLEXSTREET ELL 7.PVC SCHEDULE 80 NIPPLE (6" MIN. LENGTH) 8.LATERAL LINE PIPING. 9.LATERAL LINE PIPE FITTING. NOTE: TEFLON TAPE ALL THREADED JOINTS. NOTE: INDIVIDUAL PROJECT REQUIREMENTS AND LOCAL CODES MAY DICTATE DIFFERENCES IN INSTALLATION PROCEDURE THAT ARE NOT IDENTIFIED HERE.FELDMANDESIGN STUDIOSSHEET NO. L2.02 Scale: 1" = 1' DOUBLE CHECK VALVE ASSEMBLY Not to Scale WEATHERMATIC SL1600 SERIES CONTROLLER Not to Scale LINE FLUSHING VALVE DETAIL Scale: 1/4" = 1' SLEEVE/BORING DETAIL IRRIGATION DETAILS P.O. Box 832346, Richardson, Texas 75083Mobile: 972 523-4944carol@feldmandesign.comNot to Scale POP-UP SPRAY HEAD ON ARM RETAIL 4767 W MAIN STREETCOPPELL, TEXAS OLD TOWN ADDITION