Freeport NIP(2.2)-LR011219CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0070 8901 Carpenter Frwy., Suite #100 Service Date: November 19, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: December 19, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 12:30pm Date Cast: November 19, 2001 Technician: Jason Kale Batch Time: 11:12am Plant: 31 Weather Conditions: Cloudy, windy Supplier: TXI Accumulative Yards: 10 Truck No: 139 Ticket No: 3027168 Placement Method: Direct Discharge Mix I.D. No.: 8273 Sample Locations: See attached sketch Water Added Onsite Before Test: 5 Gallons Placement Location: Paving Field Test Data Test Result Specification Test Method Slump, inches: 4.25 3-5 ASTM C-143 Air Content, %: 5.0 3-6 ASTM C-231 Concrete Temperature,o F: 71 ASTM C1064 Ambient Temperature, o F: 54 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/26/2001 7 89,270 3,160 1 2 6.00 28.27 11/26/2001 7 87,920 3,110 Average 3,140 1 3 6.00 28.27 12/17/2001 28 120,230 4,250 1 4 6.00 28.27 12/17/2001 28 119,790 4,240 Average t~t 4,250 Services - Obtain samples of fresh concrete at the placement locations, perform required field s and cast e strength samples. Report Distribution: (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by: (1) R L Goodson Consulting Engineers (1) City of Coppell - Bldg Insp ' (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1