Freeport NIP(2.2)-LR011218 (2)CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94011204.0069 ~,~n~,~.~.
8901 Carpenter Frwy., Suite #100
Service Date: November 19, 2001 Dallas, Texas 75247
(214) 630-1010
Client: TNA Nodh American, Inc. Report Date: December 18, 2001
Attn: Terry Raley Project: Sales Office & Warehouse Fac.
1321 Valwood Parkway, Suite 440 Coppell, Texas
Carrollton TX 75006
Project Number: 94011204
Material Information Sample Information
Specified Strength: 3000 psi @ 28 Days Sample Time: 7:20am Date Cast: November 19, 2001
Technician: Jason Kale
Batch Time: 6:32am Plant: 41 Weather Conditions: Windy, cloudy
Supplier: TXI Accumulative Yards: 1
Truck No: 922 Ticket No: 3026747 Placement Method: Pump
Mix I.D. No.: 9505 Sample Locations: C-D, 6.8-C
Placement Location: Elevated slab on metal second floor
mezzanine Line 6-7
(See attached sketch)
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.75 2-4 ASTM C-143
Air Content, %: 3.1 N/A ASTM C-231
Concrete Temperature, o F: 73 ASTM C1064
Ambient Temperature, o F: 55 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 11/26/2001 7 85,110 3,010
1 2 6.00 28.27 11/26/2001 7 84,690 2,990
3,0(
1 3 6.00 28.27 12/17/2001 28 107,
1 4 6.00 28.27 12/17/2001 28 1 010
Average 3,670
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. 0~<Lw~o
Page 1 of 2
CONCRETE
COMPRESSIVE
STRENGTH TEST
Report Number: 94011204.0069 ~a;N~,~.
8901 Carpenter Frwy., Suite #100
Service Date: November 19, 2001 Dallas, Texas 75247
(214) 630-1010
Client: TNA North American, Inc. Report Date: December 18, 2001
Attn: Terry Raley Project: Sales Office & Warehouse Fac.
1321 Valwood Parkway, Suite 440 Coppell, Texas
Carrollton TX 75006
Project Number: 94011204
Material Information Sample Information
Specified Strength: 3000 psi @ 28 Days Sample Time: 9:00am Date Cast: November 19, 2001
Technician: Jason Kale
Batch Time: 7:33am Plant: 41 Weather Conditions: Windy, cloudy
Supplier: TXI Accumulative Yards: 10
Truck No: 723 Ticket No: 3026832 Placement Method: Direct Discharge
Mix I.D. No.: 9505 Sample Locations: A-D (Sample 3-A)
Placement Location: Slab leaveout area around perimeter of
bldg. Line 1-7
Field Test Data
Test Result Specification Test Method
Slump, inches: 6.00 2-4 ASTM C-143
Air Content, %: 3.3 N/A ASTM C-231
Concrete Temperature,o F: 71 ASTM C1064
Ambient Temperature, 0 F: 54 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
2 1 6.00 28.27 11/26/2001 7 90,660 3,210
2 2 6.00 28.27 11/26/2001 7 92,440 3,270
Average 3,240
2 3 6.00 28.27 12/17/2001 28 117,350 4,150
2 4 6.00 28.27 12/17/2001 28 117,560 4,160
Average 4,160
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Jason Kale ~..,~J J
Report Distribution: ~__~Engi~eering, Inc.
(1) TNA North American, Inc. (1) FACServices Inc
(1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by:
(1) R L Goodson Consulting Engineers (1) City of Coppell - Bldg Insp Eric J. Cleveland, P.E.
(1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2 ~Lw,~,