PA9702-LR000107 ~ ~' I-BC REPORT OF ULTRASONIC INSPECTION DATE OF SERVICE: 01/07/00 REPOI~' NO.: 0001529 CLIENT NO.: COPPELL PROJECT No.: 94991118 CLIENT: City Of COppCll PROJECT: Coppell Aquatic/Recreation Ctr. 732 DeForest 300 Block of Parkway Blvd Coppell, Texas 75019 Coppell, Texas/Prj. #96051 PAGE NO.: I Of 1 REPORT OF INSPECTION INSTRUMENT/SN: QTE 991132 LONG. FREQJSIZE: 2.25 MHZ/I" dia. CERTIFICATION DATE: 9-99 SHEAR FREQ./SlZE: 2.25 MHTJS/8"-70° PURPOSE OF TEST: Weld Inspection CALIBRATION: EW/DSC Block SPECIFICATION: AWS D1.1-98 COOPLANT: Cellulose SCAN SENSmVlTY: 86DB TEST METHOD: Angle Beam ITEM QUANTITY DESCRIPTION RESULTS I I Roof truss which will span across indoor pool area on Line 1 l, piece mark T3: a. Top chord weld splice. Comply b. Bottom chord weld splice. Comply Technician: R. Walcker, Level lI Report Distribution: I"BC Engineering, Inc. ( 1 ) City of Coppell ( 1 ) City of Coppell - Engineering ~ (I) Brinkley Sargent Architects (1) City of Coppell - Bldg. ( 1 ) Turner Engineers ( 1 ) City of Coppell - Leisure Serv. Dept. (1) Hisaw &Associates Paul D. Smith, P. E. Senior Project Engineer ss TIffs report is exclusively for ~c use of the client indicated above and shall not be reproduced in full witbo~t walden approval of HBC Engineenng, Inc.