PA9702-LR000107 ~ ~' I-BC
REPORT OF ULTRASONIC INSPECTION
DATE OF SERVICE: 01/07/00 REPOI~' NO.: 0001529
CLIENT NO.: COPPELL PROJECT No.: 94991118
CLIENT: City Of COppCll PROJECT: Coppell Aquatic/Recreation Ctr.
732 DeForest 300 Block of Parkway Blvd
Coppell, Texas 75019 Coppell, Texas/Prj. #96051
PAGE NO.: I Of 1
REPORT OF INSPECTION
INSTRUMENT/SN: QTE 991132 LONG. FREQJSIZE: 2.25 MHZ/I" dia.
CERTIFICATION DATE: 9-99 SHEAR FREQ./SlZE: 2.25 MHTJS/8"-70°
PURPOSE OF TEST: Weld Inspection CALIBRATION: EW/DSC Block
SPECIFICATION: AWS D1.1-98 COOPLANT: Cellulose
SCAN SENSmVlTY: 86DB
TEST METHOD: Angle Beam
ITEM QUANTITY DESCRIPTION RESULTS
I I Roof truss which will span across indoor pool area on
Line 1 l, piece mark T3:
a. Top chord weld splice. Comply
b. Bottom chord weld splice. Comply
Technician: R. Walcker, Level lI
Report Distribution: I"BC Engineering, Inc.
( 1 ) City of Coppell ( 1 ) City of Coppell - Engineering ~
(I) Brinkley Sargent Architects (1) City of Coppell - Bldg.
( 1 ) Turner Engineers ( 1 ) City of Coppell - Leisure Serv. Dept.
(1) Hisaw &Associates Paul D. Smith, P. E.
Senior Project Engineer
ss TIffs report is exclusively for ~c use of the client indicated above and shall not be reproduced in full witbo~t walden approval of HBC Engineenng, Inc.